Illustration 1 g00728931
Typical exampleTest Step 1. Check for Connector Damage.
Disconnect main power.
Thoroughly inspect the ECM connectors J1/P1 and J2/P2. Inspect all of the other connectors. Refer to Troubleshooting, "Inspecting Electrical Connectors" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the customer connector (allen head screw) for the proper torque of 2.25 0.25 N m (20 2 lb in).
Check the harness and the wiring for abrasion and pinch points.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring should be free of corrosion, abrasion or pinch points.Results:
OK - The connectors and wiring are okay. Proceed to test step 2.
Not OK - The connectors and/or wiring need repair.Repair: Repair the connectors and/or wiring or replace the connectors and/or wiring. Stop.Test Step 2. Check the ON Status of the Emergency Stop Switch.
Turn the circuit breaker for the battery to the ON position.
Connect the ET.
Turn the ECS to the STOP position.
Activate the emergency stop switch.
Observe the status of the emergency stop switch on the ET.Expected Result:The parameter for the emergency stop switch should read "ON".Results:
OK - The emergency stop switch is working correctly. Proceed to test step 3.
Not OK - The parameter for the emergency stop switch does not display "ON". Proceed to test step 4.Test Step 3. Check the OFF Status of the Emergency Stop Switch.
Deactivate the emergency stop switch.Expected Result:The parameter for the emergency stop switch should read "OFF".Results:
OK - The emergency stop switch is functioning correctly. Stop.
Not OK - The parameter for the emergency stop switch does not display "OFF". Proceed to test step 4.Test Step 4. Test the ECM.
Turn the ECS to the OFF/RESET position.
Disconnect connector P1 from the ECM. Remove wires P1-29, P1-02 and P1-24 from ECM connector P1.
Locate a suitable jumper wire.
Insert the jumper wire at P1. Connect P1-02 and P1-24 to P1-29.
Reconnect connector P1 to ECM connector J1.
Turn the ECS to the STOP position.
Observe the parameters for the emergency stop on the ET.
Turn the ECS to the OFF/RESET position. Remove the jumper wire and reinstall all wires.Expected Result:The parameter for the emergency stop switch should display "OFF" when the jumper is installed. The parameter for the emergency stop switch should display "ON" when the jumper is removed.Results:
OK - The problem is not with the ECM. Proceed to test step 5.
Not OK - The parameter on the ECM is incorrect.Repair: Replace the ECM. Refer to Troubleshooting, "Replacing the ECM". Stop.Test Step 5. Check the Switches and the Wiring.
Turn the ECS to the OFF/RESET position.
Disconnect connector P1 from ECM connector J1.
Activate the emergency stop switch.
Measure the resistance between P1-29 and P1-02.
Measure the resistance between P1-29 and P1-24.Expected Result:The resistance should be greater than 20,000 Ohms.Results:
OK - The resistance is greater than 20,000 Ohms. Proceed to test step 6.
Not OK - The resistance is less than 20,000 Ohms. There is a short circuit in the emergency stop switch.Repair: Repair the switch or wiring and/or replace the switch or wiring. Stop.Test Step 6. Deactivate the Switch.
Deactivate the emergency shutdown switch.
Measure the resistance between P1-29 and P1-02.
Measure the resistance between P1-29 and P1-24.Expected Result:The resistance should read less than 10 Ohms.Results:
OK - The resistance is less than 10 Ohms. The emergency shutdown switch is okay. Stop.
Not OK - The resistance is greater than 10 Ohms. There is an open circuit in the emergency shutdown switch.Repair: Repair the switch or wiring and/or replace the switch or wiring. Stop.


Parts clamp JOHNSON:

0510190
 
0510190 CLAMP
1R69C, 1R70R, 20R73A, 25E73A, 25E74M, 25E75B, 25E76E, 2R71A, 2R72M, 2R73B, 2R74E, 2R75D, 2R76S, 2R77C, 2R78R, 2R79A, 33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40ES69R, 40ES70A, 40R69R, 40R70A, 9R69S, 9R70A, 9R71R, 9R72M,
0375742
CLAMP SCREW ASSY
0375742 CLAMP SCREW ASSY
2R74E, 2R75D, 2R76S, 4R69B, 4R70E, 4R71D, 4R72S, 4R73C, 4R74R, 4R75A, 4R76M, 6R69M, 6R70B, 6R71E, 6R72D, 6R73S, 6R74C, 6R75R, 6R76A, CD-25A, JH-23A, LD-13B
0315224
 
0315224 CLAMP, Stern bracket 5" EXTENSION KIT
1R69C, 1R70R, 2R71A, 2R72M, 2R73B, 2R74E, 2R75D, 2R76S, 2R77C, 2R78R, 2R79A, J2RCIB, J2RCNE, J2RCOC, J2RCRS, J2RCSM, J2RCTD, JCO-CCM, JCO-CDR, JCO-CEB, JCO-CUA, JCO-ESE
0320107
 
0320107 CLAMP STRAP, Hose
100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 175TL77
0388346
CLAMP SCR.&HAND.ASSY.
0388346 CLAMP SCR.&HAND.ASSY.
2R77C, 2R78R, 2R79A, 4R77B, 4R78E, 4R79D, 6R77M, 6R78B, 6R79E, J2RCNE, J2RCOC, J2RCRS, J2RCSM, J2RCTD, J4BRHCNR, J4BRHCOB, J4BRHCRM, J4BRHCTA, J4RLCSS, J4WCNR, JCO-CDR, JCO-CUA
0322654
CLAMP,Hose to carb.
0322654 CLAMP,Hose to carb.
2R77C, 2R78R, 2R79A, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSSB, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, BJ3REDS, BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ
0391428
 
0391428 CLAMP SCR. & HAND. ASSY.
J2RCIB, J2RCNE, J2RCOC, J2RCRS, J2RCTD, J4BRCIC, J4BRHCNR, J4BRHCOB, J4BRHCRM, J4BRHCTA, J4WCIC, J4WCNR, JCO-CDR, JCO-CUA
Back to top