0321084 CLAMP,Solenoid lead to carb JOHNSON
115EL77S, 115TXL77S, 140ML77S, 150TL78S, 175TL77S, 175TL78C, 200TL76S, 200TL77C, 200TL78R, 235TL78R, 85EL76D, 85EL77S, 85TXLR77S
CLAMP
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- INTAKE MANIFOLD » 0321084
140ML77S, 140TL77S, 140TXL77S 1977
150TL78S, 150TXL78S 1978
175TL77S, 175TXL77S 1977
175TL78C, 175TX78C 1978
200TL76S, 200TXL76S 1976
200TL77C, 200TXL77C 1977
200TL78R, 200TX78R 1978
235TL78R, 235TX78R 1978
85EL76D, 85EL76G, 85ETLR76D, 85ETLR76G 1976
85EL77S, 85ETLR77S 1977
85TXLR77S 1977
Information:
Illustration 1 g00362864
Illustration 2 g00367673
Typical exampleWhen the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 6950 1650 rpm Current draw ... 115 25 amp Voltage ... 23 V (1) Nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (2) NutThree wires are the maximum that may fit between the nuts. Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (3) Ground Terminal Tighten the ground terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) NutThe terminal that is on the switch terminal must be insulated with heat shrink tubing. Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Nut Tighten the nut on the motor terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (6) Nut Tighten the nut on the motor frame terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft)SolenoidCurrent draw at 20 V and 25 °C (77 °F) Pull-in windings ... 49.3 3.3 Amp Hold-in windings ... 6.8 Amp maximum6V-5540
Illustration 3 g00282750
Typical exampleWhen the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 5500 rpm minimum Current draw ... 140 amp maximum Voltage ... 24 V (1) NutThree wires are the maximum that may fit between the nuts. Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (2) Nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (3) Nut Tighten the nut on the ground terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) NutThe terminal that is on the switch terminal must be insulated with heat shrink tubing. Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Nut Tighten the nut on the motor terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (6) Nut Tighten the nut on the motor frame terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft)SolenoidCurrent draw at 24 V and 25 °C (77 °F) Pull-in windings ... 51 Amp Hold-in windings ... 7 Amp maximum6V-5582
Illustration 4 g00282453
Illustration 5 g00282454
Typical exampleWhen the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Minimum speed with no load ... 3300 rpm Maximum current with no load ... 80 amp Voltage ... 24 V (1) NutThree wires are the maximum that may fit between the nuts. Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (2) Nut Tighten the nut to the following torque. ... 1.5 0.5 N m (13 4 lb in) (3) Nut Tighten the ground terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (4) NutThe terminal that is on the switch terminal must be insulated with heat shrink tubing. Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Nut Tighten the nut on the motor terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (6) Nut Tighten the nut on the motor frame terminal to the following torque. ... 17.5 2.5 N m (13 2 lb ft)SolenoidCurrent draw at 24 V and 25 °C (77 °F) Pull-in windings ... 103 Amp Hold-in windings ... 19 Amp maximum6V-4213
Illustration 6 g00286672
Illustration 7 g00286673
Typical exampleWhen the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 6900 1800 rpm Current draw ... 127.5 27.5 amp Voltage ... 11 V (1) NutThree wires are the maximum that may fit between the nuts. Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (2) Nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (3) Nut Tighten the nut on the ground terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) NutThe terminal that is on the switch terminal must be insulated with heat shrink tubing. Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Nut Tighten the nut on the motor terminal to the following torque. ... 30.5 3.5 N m (22 3 lb ft) (6) Nut Tighten the nut on the motor frame terminal to the following torque. ... 8 3 N m (71 27 lb in)SolenoidCurrent draw at 20 V and 25 °C (77 °F) Pull-in windings ... 92.5 7.5 amp Hold-in windings ... 23 amp
Parts clamp JOHNSON:
0510409
0510409 CLAMP,H.T.lead
115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25R69B, 25R70C, 25R71S, 4R69B, 4R70E, 4R71D, 4R72S, 4R73C, 4R74R, 4R75A, 4R76M, 65ES72S, 65ES73R,
0310441
0310441 CLAMP,Switch leads
100ESL71A, 100ESL72R, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 150TL78S, 175TL77S, 175TL78C, 200TL77C, 200TL78R, 235TL78R, 25E77S
0309040
0309040 CLAMP, Solenoid lead
100ESL71A, 100ESL72R, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 40E69R, 40E70A, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 50ES71S, 50ES
0316014
0316014 CLAMP,Retainer
100ML79S, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 23
0317755
0317755 CLAMP
10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 35E76G, 4R77B, 4R78E, 50ES73R, 50ES74M, 50ES75B, 50R79C,
0318607
0318607 CLAMP,Cable casing guide
115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 150TL78S, 175TL77S, 175TL78C, 200TL76S, 200TL77C, 200TL78R, 235TL78R, 50ES73R, 50ES74M, 50ES75B, 55E76E, 55E77D, 55E78S, 65ES73R, 70
0321383
0511411
0511411 CLAMP
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, 85TXLR77S, HJ15KCF, HJ15KCLO, J100MLCSC, J100WTL