0318955 CLEVIS, Link to bellcrank JOHNSON
10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, J10ECDB, J10ECES, J10ECOM, J10ECSE, J10ECUE, J10EEIR, J10EENA, J10EESC, J10ELCID, J10ELCNS, J10ELCRA, J10ELCTC, J15ECDE, J15ECEC, J15ECIS, J15ECNC, J15EC
CLEVIS
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BRP JOHNSON entire parts catalog list:
- CYLINDER & CRANKCASE » 0318955
10E76G, 10E76H, 10E76R, 10EL76G, 10EL76H, 10EL76R, 10R76G, 10R76H, 10R76R, 10RL76G, 10RL76H, 10RL76R 1976
10E77A, 10EL77A, 10R77A, 10RL77A 1977
10E78M, 10EL78M, 10R78M, 10RL78M, 10SEL78M 1978
10EL79B, 10R79B, 10RL79B, 10SEL79B 1979
15E74G, 15E74S, 15EL74G, 15EL74S, 15R74G, 15R74S, 15RL74G, 15RL74S 1974
15E75C, 15EL75C, 15R75C, 15RL75C 1975
15E76A, 15E76R, 15EL76A, 15EL76R, 15R76A, 15R76R, 15RL76A, 15RL76R 1976
15E77M, 15EL77M, 15R77M, 15RL77M 1977
15E78B, 15EL78B, 15R78B, 15RL78B 1978
15E79E, 15EL79E, 15R79E, 15RL79E 1979
J10ECDB, J10ELCDB, J10RCDB, J10RLCDB, J10SELCDB 1986
J10ECES, J10ELCES, J10RCES, J10RLCES, J10SELCES, TJ10ELCES, TJ10RLCES 1989
J10ECOM, J10ELCOM, J10RCOM, J10RLCOM, J10SELCOM 1985
J10ECSE, J10ELCSE, J10RCSE, J10RLCSE, J10SELCSE 1980
J10ECUE, J10ELCUE, J10RCUE, J10RLCUE, J10SELCUE 1987
J10EEIR, J10ELEIR, J10REIR, J10RELEIR, J10RLEIR, J10SELEIR, TJ10RELEIR 1991
J10EENA, J10ELENA, J10RELENA, J10RENA, J10RLENA, J10SELENA, TJ10RELENA 1992
J10EESC, J10ELESC, J10RELESC, J10RESC, J10RLESC, J10SELESC, TJ10ELESC, TJ10RELESC, TJ10RLESC 1990
J10ELCID, J10RCID, J10RLCID, J10SELCID 1981
J10ELCNS, J10RCNS, J10RLCNS, J10SELCNS 1982
J10ELCRA, J10RCRA, J10RLCRA, J10SELCRA 1984
J10ELCTC, J10RCTC, J10RCTR, J10RLCTC, J10RLCTR, J10SELCTC 1983
J15ECDE, J15ELCDE, J15RCDE, J15RLCDE 1986
J15ECEC, J15ELCEC, J15RCEC, J15RLCEC, TJ15RLCEC 1989
J15ECIS, J15RCIS, J15RLCIS 1981
J15ECNC, J15RCNC, J15RLCNC 1982
J15ECOB, J15ELCOB, J15RCOB, J15RLCOB 1985
J15ECRM, J15ELCRM, J15RCRM, J15RLCRM 1984
J15ECSD, J15ELCSD, J15RCSD, J15RLCSD 1980
J15ECTR, J15ELCTR, J15RCTA, J15RCTR, J15RLCTA, J15RLCTR 1983
J15ECUD, J15ELCUD, J15RCUD, J15RLCUD 1987
J15EEIA, J15ELEIA, J15REIA, J15RELEIA, J15RLEIA 1991
J15EENM, J15ELENM, J15RELENM, J15RENM, J15RLENM 1992
J15EESR, J15ELESR, J15RELESR, J15RESR, J15RLESR 1990
Information:
Illustration 1 g00591520
Typical EMCP II
(1) Generator Set Control +
(2) Alarm module (option)
(3) Custom alarm module (option)
(4) Control panel (operation)
(5) Caterpillar Monitoring System Each component of the EMCP II+ is described below. The components and the control panel operation is comparable for the EMCP II.Generator Set Control +
The Generator Set Control + (GSC+) is the main component of the EMCP II+. The control is powered by a battery system with 24 VDC or 32 VDC. The control has several functions and features.The GSC+ controls normal starting and stopping of the engine. When a signal is received to start the engine, the fuel and the starting motor are activated. When the engine speed reaches the crank terminate speed, the starting motor is disengaged. When a signal is received to stop the engine, the fuel is shut off to the injectors.The control system is designed to remove power from the GSC+ when the Engine Control Switch is in the "OFF/RESET" position. However, the GSC+ will not permit power to be removed until the crank termination relay and the fuel control relay are OFF for approximately 70 seconds.Note: A jumper wire may be installed between terminal 6 and terminal 9 of the Engine Control Switch. The wire will allow the GSC+ to remain powered while the Engine Control Switch is in the "OFF/RESET" position. This can be used by service technicians to troubleshoot a shutdown fault that is ACTIVE.
Illustration 2 g00591650
(1) Indicators
(2) Upper display
(3) Lower display
(4) Keypad The GSC+ activates the indicators (1) for alarm conditions and for shutdown conditions. The GSC+ can transmit signals that represent the conditions to alarm modules in order to activate annunciation. The GSC+ controls shutdowns that are caused by events or by diagnostics from a failed component. For a description of the indicators, see the "Alarm Mode" and "Shutdown Mode" topics below.The GSC+ monitors the status of engine operation and generator operation. Displays (2) and (3) show the following items: status of engine operation, status of generator operation, event codes, diagnostic codes and programmed information.Keypad (4) is used for changing displays (2) and (3). The keypad is also used for programming certain features. For example, the crank cycle and the cooldown timer can be programmed.Note: To ensure proper operation with EUI systems, the "P023" setpoint of the GSC+ must be programmed to a value of "2". Otherwise, the engine will not operate properly. Also, an erroneous component identifier ("CID 590") will be LOGGED. For information on programming, see the EMCP II Service Manual.The GSC+ has connectors for an optional Customer Communication Module (CCM). The CCM allows the generator set to be controlled and monitored from a remote location. Remote communications can be established with any personal computer or other RS-232C communications device.The GSC+ has these four modes of operation: normal, alarm, shutdown and service.Normal Mode
The GSC+ is in normal mode during normal operation. None of the indicators are illuminated. The upper display does NOT show "SERV".
Illustration 3 g00591848
Keypad
(1) "POWER METER"
(2) "AC METER"
(3) "ENGINE METER"
(4) "LAMP TEST"
(5) "ALARM CODES"
(6) "EXIT"
(7) "SERVICE MODE" Note: Keys (1), (2), (3), (4), and (5) function differently when the GSC+ is in the service mode.Upper display
The upper display shows the status of the following parameters for the generator: AC voltage, current and frequency. To view the following information individually, press the "AC METER" key (2) (Illustration 3):
Average voltage, frequency of the generator, and total current
Line-to-line voltage, frequency of the generator, and line current for any phase
Line-to-line voltage for all three phases
Line current for all three phases
Line to neutral voltage for all three phasesNote: When the total current increases to more than 9999 amperes, the current is displayed in kA.Note: For the delta generator set, the line to neutral voltage is not shown when the "P032" setpoint is programmed to "1".Lower display
The lower display shows values for these items:
Power output of the generator
Status of engine parameters
Status of the relaysThe left side of the lower display serves as a power meter for the generator set. The following parameters scroll automatically: total real power (kW), total reactive power (kVAR), percentage of rated power (% kW), average power and total output of energy (kW/h).In order to display a particular parameter continuously, press "POWER METER" key (1) (Illustration 3) for less than five seconds.If the "POWER METER" key is pressed for more than five seconds and then released, these additional parameters scroll on the display: total real power (kW), real power of each phase, total apparent power (kVA), total reactive power (kVAR), percentage of rated power (% kW), average power, power factor of each phase, total output of energy (kW/h) and total reactive power output (kVAR/h).Note: All of the real values for power are identified with a positive "+" sign or a negative "-" sign. A negative sign indicates reverse power.Note: For the delta generator set, the real power and the power factor for all three phases are not displayed when the "P032" setpoint is programmed to "1".The right side of the lower display shows the value of the following engine parameters:
Exhaust temperature (option)
Engine oil temperature (option)
System battery voltage
Engine hours
Parts clevis JOHNSON:
0323776
0323776 CLEVIS PIN,Shift and throttle lever
100ML79S, 115ML79R, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 50R79C, 55E79C, 70EL79R, 75ELR79R, 85ML79R, CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM, HJ55WMLM, HJ55WMLZ, J100MLCSC, J100STLCCA, J100STLCEM, J100STLESB, J100WMLCDR,