0438251 CLUTCH SHAFT ASSY. JOHNSON
BJ130TLEDM, BJ130TLEUB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, BJ250CXECB, BJ250CXEDA, BJ250CXEUM
CLUTCH
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$211.11
05-03-2024
5.0[2.25] pounds
US: SEI Marine Products
SEI Marine Products-Compatible with - Evinrude Johnson Inner Prop Shaft 0438251 V6 Counter Rotation 1988-Current
SEI Marine Products This inner prop shaft replaces OE#: 0438251 and fits V6 counter rotation Evinrude Johnson outboard lower units from 1988-current.
SEI Marine Products This inner prop shaft replaces OE#: 0438251 and fits V6 counter rotation Evinrude Johnson outboard lower units from 1988-current.
Compatible models:
BJ130TLEDM
BJ130TLEUB
BJ150ELECD
BJ150ELEDB
BJ150ELEUC
BJ175EXECD
BJ175EXEDB
BJ175EXEUC
BJ175PLEES
BJ175PLSIF
BJ175PLSSC
BJ200CXEDR
BJ200CXEEB
BJ200CXSSE
BJ200PLSIF
BJ225CXEEC
BJ225CXSSR
BJ225PLSIF
BJ250CXECB
BJ250CXEDA
BJ250CXEUM
J150CXEES
J150CXSSC
J150FCXECR
J150ICXEUC
J150JPLSIF
J175FCXECS
J200CXECM
J200CXEUA
J225CXECS
J225CXEDE
J225CXEUD
J225HPLEEN
J225HPLSIF
J225HPLSSC
J250CXECD
J250CXEEN
J250CXSSS
J250VCZSIF
JOHNSON
BRP JOHNSON entire parts catalog list:
- GEARCASE - 130CX COUNTER ROTATION » 0438251
BJ150ELECD, BJ150EXECD, BJ150GLECD, BJ150NXECD, J150ELECD, J150EXECD, J150GLECD, J150JLECD, J150NXECD, J150SLECD 1998
BJ150ELEDB, BJ150EXEDB, BJ150GLEDB, BJ150NXEDB, J150ELEDB, J150EXEDB, J150GLEDB, J150JLEDB, J150NXEDB, J150SLEDB, SJ150ELEDB 1996
BJ150ELEUC, BJ150ELEUE, BJ150EXEUC, BJ150EXEUE, BJ150GLEUC, BJ150GLEUE, BJ150NXEUC, BJ150NXEUE, J150ELEUC, J150ELEUE, J150EXEUC, J150EXEUE, J150GLEUC, J150GLEUE, J150JLEUC, J150JLEUE, J150NXEUC, J150NXEUE, J150SLEUC, J150SLEUE 1997
BJ175EXECD, BJ175GLECD, BJ175NXECD, J175EXECD, J175GLECD, J175NXECD, J175SLECD 1998
BJ175EXEDB, BJ175GLEDB, BJ175NXEDB, J175EXEDB, J175GLEDB, J175NXEDB, J175SLEDB 1996
BJ175EXEUC, BJ175EXEUE, BJ175GLEUC, BJ175GLEUE, BJ175NXEUC, BJ175NXEUE, J175EXEUC, J175EXEUE, J175GLEUC, J175GLEUE, J175NXEUC, J175NXEUE, J175SLEUC, J175SLEUE 1997
BJ175PLEES, BJ175PXEES, J175CXEES, J175PLEES, J175PXEES, J175SPLEES 1999
BJ175PLSIF, BJ175VXSIF, J175PLSIF, J175VCXSIF, J175VLSIF, J175VXSIF, RJ175CXSIF, RJ175PLSIF, RJ175VXSIF 2001
BJ175PLSSC, BJ175PXSSC, BJ175VXSSS, J175CXSSS, J175PLSSC, J175PXSSC, J175SPLSSC, J175VCXSSS, J175VLSSS, J175VXSSS, RJ175CXSSS, RJ175PLSSC, RJ175VXSSS 2000
BJ200CXEDR, BJ200TXEDR, J200CXEDR, J200STLEDM, J200TXEDR, LJ200SLEDR, SJ200SLEDM 1996
BJ200CXEEB, BJ200CXEEN, BJ200PLEEB, BJ200PLEEN, BJ200PXEEB, BJ200PXEEN, J200CXEEB, J200CXEEN, J200PLEEB, J200PLEEN, J200PXEEB, J200PXEEN 1999
BJ200CXSSE, BJ200PLSSC, BJ200PXSSC, BJ200VCSSS, BJ200VXSSS, J200CXSSE, J200PLSSC, J200PXSSC, J200VCXSSS, J200VXSSS, RJ200PLSSC, RJ200PXSSC, RJ200VXSSS 2000
BJ200PLSIF, BJ200VCSIF, BJ200VXSIF, J200PLSIF, J200VCXSIF, J200VLSIF, J200VXSIF, RJ200PLSIF, RJ200VXSIF 2001
BJ225CXEEC, BJ225CXEEN, BJ225PLEEC, BJ225PLEEN, BJ225PXEEC, BJ225PXEEN, J225CXEEC, J225CXEEN, J225HPLEEN, J225HPLEES, J225PLEEC, J225PLEEN, J225PXEEC, J225PXEEN 1999
BJ225CXSSR, BJ225PLSSR, BJ225PXSSR, BJ225VCSSS, BJ225VXSSS, J225CXSSR, J225HGLSSC, J225HPLSSC, J225PLSSR, J225PXSSR, J225VCXSSS, J225VXSSS, RJ225CXSSS, RJ225HGSSC, RJ225HLSSC, RJ225PLSSR, RJ225PXSSR, RJ225VXSSS 2000
BJ225PLSIF, BJ225VCSIF, BJ225VXSIF, J225HGLSIF, J225HPLSIF, J225PLSIF, J225VCXSIF, J225VLSIF, J225VXSIF, RJ225CXSIF, RJ225HLSIF, RJ225PLSIF, RJ225VXSIF 2001
BJ250CXECB, BJ250TXECB 1998
BJ250CXEDA, BJ250TXEDA 1996
BJ250CXEUM, BJ250TXEUM 1997
J150CXEES, J150JPLEES, J150PLEES, J150PXEES, J150SPLEES 1999
J150CXSSC, J150JPLSSC, J150MXSSD, J150PLSSC, J150PXSSC, J150SPLSSC, J150VCSSS, J150VLSSS, J150VXSSS, RJ150CXSSC, RJ150PLSSC, RJ150PXSSC, RJ150VCSSS, RJ150VLSSS, RJ150VXSSS 2000
J150FCXECR, J150FSLECR, J150FSXECR, J150ILECR 1998
J150ICXEUC, J150ILEUC, J150IXEUC, J150PLEUC 1997
J150JPLSIF, J150PLSIF, J150VCXSIF, J150VLSIF, J150VXSIF, RJ150PLSIF, RJ150VCSIF, RJ150VLSIF, RJ150VXSIF 2001
J175FCXECS, J175FSLECS, J175FSXECS, J175FTLECS 1998
J200CXECM, J200STLECE, J200TLECM, J200TXECM, SJ200CXECM, SJ200SLECE, SJ200TXECM 1998
J200CXEUA, J200STLEUB, J200TXEUA, SJ200CXEUA, SJ200SLEUB, SJ200TXEUA 1997
J225CXECS, J225CZECS, J225STLECS, J225TXECS, J225TZECS, SJ225CXECS, SJ225GLECC, SJ225NXECC, SJ225NZECC, SJ225QXECC, SJ225QZECC, SJ225SLECS, SJ225TXECS 1998
J225CXEDE, J225CZEDE, J225PXEDE, J225STLEDE, J225TXEDE, J225TZEDE, SJ225CXEDE, SJ225PXEDE, SJ225SLEDE, SJ225TXEDE 1996
J225CXEUD, J225CZEUD, J225STLEUD, J225TXEUD, J225TZEUD, SJ225CXEUD, SJ225SLEUD, SJ225TXEUD 1997
J225HPLEEN, J225HPLEES 1999
J225HPLSIF 2001
J225HPLSSC 2000
J250CXECD, J250CZECD, J250PXECD, J250PZECD 1998
J250CXEEN, J250CXEES, J250CZEEN, J250CZEES, J250PXEEN, J250PXEES, J250PZEEN, J250PZEES 1999
J250CXSSS, J250CZSSC, J250PXSSC, J250PZSSC, J250VCXSSS, J250VCZSSS, J250VXSSS, J250VZSSS, RJ250CXSSS, RJ250VXSSS, RJ250VZSSS 2000
J250VCZSIF, J250VXSIF, J250VZSSIF, RJ250VXSIF, RJ250VZSSIF 2001
Information:
Never run the engine without an air cleaner element installed. Never run the engine with a damaged air cleaner element. Do not use air cleaner elements with damaged pleats, gaskets or seals. Dirt entering the engine causes premature wear and damage to engine components. Air cleaner elements help to prevent airborne debris from entering the air inlet.
Never service the air cleaner element with the engine running since this will allow dirt to enter the engine.
Servicing the Air Cleaner Elements
If the air cleaner element becomes plugged, the air pressure can split the filter material of the element. Unfiltered air will drastically accelerate internal engine wear. Your Caterpillar dealer has the proper air cleaner elements for your application.The air cleaner may be mounted high above the engine. If necessary, use a ladder or a platform to reach the air cleaner.
Check the precleaner (if equipped) daily for accumulation of dirt and debris. Remove any dirt and debris, as needed.
Operating conditions (dust, dirt and debris) may require more frequent service of the air cleaner element.
The air cleaner element may be cleaned up to six times if the element is properly cleaned and inspected.
The air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.Replace the dirty paper elements with clean elements. Before installation, thoroughly inspect the element for tears and/or holes in the filter material. Inspect the gasket or the seal of the element for damage. Maintain a supply of suitable elements for replacement purposes.
Illustration 1 g00317608
Fasteners for the air cleaner cover
Illustration 2 g00781084
(1) Cover
(2) Element
(3) Air inlet
Release the fasteners for cover (1).
Remove the cover and element (2).
Cover air inlet (3) with tape in order to keep dirt out.
Clean the inside of the cover and the body with a clean, dry cloth.
Remove the tape for the air inlet. Install a new element or a clean element.
Install the cover.
If necessary, reset the air cleaner service indicator. Cleaning the Primary Air Cleaner Elements
The primary air cleaner element can be used up to six times if the element is properly cleaned and inspected. When the element is cleaned, check the filter material for rips or tears. Replace the element at least one time per year regardless of the number of cleanings.Use clean elements while dirty elements are being cleaned.
Do not clean the air cleaner elements by bumping or tapping. This could damage the seals. Do not use elements with damaged pleats, gaskets or seals. Damaged elements will allow dirt to pass through. Engine damage could result.
Visually inspect the elements before cleaning. Inspect the elements for damage to the seal, the gaskets, and the outer cover. Discard any damaged elements.Air cleaner elements can be cleaned with pressurized air and with a vacuum.Pressurized Air
Pressurized air can be used to clean elements that have not been cleaned more than two times. Pressurized air will not remove deposits of carbon and oil. Use filtered, dry air with a maximum pressure of 207 kPa (30 psi).
Illustration 3 g00281692Note: When the elements are cleaned, always begin with the clean side (inside) in order to force dirt particles toward the dirty side (outside).Aim the hose so that the air flows inside the element along the length of the filter in order to help prevent damage to the paper pleats. Do not aim the stream of air directly at the primary air cleaner element. Dirt could be forced into the pleats.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Vacuum Cleaning
Vacuum cleaning is a good method for cleaning elements which require daily cleaning because of a dry, dusty environment. Cleaning with pressurized air is recommended prior to vacuum cleaning. Vacuum cleaning will not remove deposits of carbon and oil.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Inspecting the Primary Air Cleaner Elements
Illustration 4 g00281693Inspect the clean, dry element. Use a 60 watt blue light in a dark room or in a similar facility. Place the blue light in the element. Rotate the element. Inspect the element for tears and/or holes. Inspect the element for light that may show through the filter material. If it is necessary in order to confirm the result, compare the element to a new element that has the same part number.Do not use an element that has any tears and/or holes in the filter material. Do not use an element with damaged pleats, gaskets or seals. Discard damaged elements.Storing Primary Air Cleaner Elements
If an element that passes inspection will not be used immediately, store the element for future use.
Illustration 5 g00281694Do not use paint, a waterproof cover, or plastic as a protective covering for storage. Restricted air flow may result. To protect against dirt and damage, wrap the elements in Volatile Corrosion Inhibited (VCI) paper.Place the element into a cardboard box for storage. For identification, mark the outside of the container and mark the element. Include the following information:
Date of cleaning
Number of cleaningsStore the container in a dry location.For more detailed information on cleaning the primary air cleaner element, refer to Special Publication, SEBF8062, "Procedure to Inspect and Clean Air Filters".