0333845 DECAL, Terminal block wiring JOHNSON
BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, J120TLAEM, J120TLAIE, J120TLAND, J120TLARC, J120TLASB, J120TLATF, J125ESXENR, J125ESXERK, J125ESXESS, J125ESXETA, J125ESXW, J125WTPLE, J130CXAOR, J140CXARC, J140CXATF, J140CXCEC,
DECAL
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- IGNITION SYSTEM » 0333845
BJ130TLECE, HJ130TXACB, J130TLECE, J130TXACB 1998
BJ130TLEDM, HJ130CXADA, HJ130TXADA, J130TLEDM, J130TXADA, SJ130CXADA, SJ130TLEDM, SJ130TXADA 1996
BJ130TLEUB, HJ130CXAUM, HJ130TXAUM, J130TLEUB, J130TXAUM 1997
BJ135PLSIF, BJ135VXSIF, J135PLSIF, J135VLSIF, J135VXSIF, RJ135PLSIF, RJ135VXSIF 2001
J120TLAEM, J120TLCEM, J120TXCEM, TJ120TXCEM 1989
J120TLAIE, J120TLEIE, J120TXEIE, VJ120TLAIE, VJ120TLEIE, VJ120TXEIE 1991
J120TLAND, J120TLEND, J120TXEND, VJ120TLAND, VJ120TLEND, VJ120TXEND 1992
J120TLARC, J120TLARK, J120TLERC, J120TLERK, J120TXARC, J120TXARK, J120TXERC, J120TXERK 1994
J120TLASB, J120TLESB, J120TXESB, VJ120TLASB, VJ120TLESB, VJ120TXESB 1990
J120TLATF, J120TLATS, J120TLETF, J120TLETS, J120TXATF, J120TXATS, J120TXETF, J120TXETS, VJ120TLATF, VJ120TLATS, VJ120TLETF, VJ120TLETS, VJ120TXETF, VJ120TXETS 1993
J125ESXENR 1992
J125ESXERK 1994
J125ESXESS 1990
J125ESXETA, J125ESXETF 1993
J125ESXW 1989
J125WTPLE 1995
J130CXAOR, J130TLEOA, J130TXAOR 1995
J140CXARC, J140CXARK, J140CXERE, J140CXERK, J140TLARK, J140TLARR, J140TLERK, J140TLERR, J140TXARC, J140TXARK, J140TXERK, J140TXERR 1994
J140CXATF, J140CXATS, J140CXETB, J140CXETF, J140TLATC, J140TLATF, J140TLETC, J140TLETF, J140TXATF, J140TXATS, J140TXETC, J140TXETF, VJ140TLETC, VJ140TLETF, VJ140TXETC, VJ140TXETF 1993
J140CXCEC, J140TLAEB, J140TLCEB, J140TXCEB 1989
J140CXEIA, J140TLEID, J140TXEID, VJ140TLAID, VJ140TLEID, VJ140TXEID 1991
J140CXENM, J140TLANS, J140TLENS, J140TXENS, VJ140TLANS, VJ140TLENS, VJ140TXENS 1992
J140CXESR, J140TLASE, J140TLESE, J140TXESE, VJ140TLASE, VJ140TLESE, VJ140TXESE 1990
SJ125WTPLJ, SJ125WTPXJ 1997
SJ125WTPLN, SJ125WTPXN 1998
SJ125WTPLV, SJ125WTPXV 1996
Information:
Table 1
Diagnostic Trouble Codes for the Air Filter Restriction Switch
J1939 Code Code Description Comments
107-3 Air Filter Differential Pressure Switch voltage above normal This code indicates a fault in the circuit for the air filter restriction switch.
The Electronic Control Module (ECM) detects the following conditions:
The air filter restriction switch circuit is open for at least 1 second.
The engine is not running.
Monitoring of air filter restriction when the engine is running will be disabled whilst this code is active.
107-4 Air Filter Differential Pressure Switch voltage below normal This code indicates a fault in the circuit for the air filter restriction switch.
The Electronic Control Module (ECM) detects the following conditions:
The air filter restriction switch circuit is grounded for at least 1 second.
The engine is not running.
Monitoring of air filter restriction when the engine is running will be disabled whilst this code is active. The engine is equipped with an air filter restriction switch. The type of switch that is installed can be a "Normally Open" switch or a "Normally Closed" switch.Use the electronic service tool to check the configuration parameters to check the type of air filter restriction switch that is installed.Table 2 and Table3 contain the normal engine conditions and switch states for the air filter restrictions switch.
Table 2
Diagnostic Summary for a "Normally Open" Air Filter Restriction Switch
Engine Condition Switch State Active Diagnostic Code
Not running (key on) Open Normal condition
Running Open Normal Condition (no air filter restriction detected)
Not running (key on) Closed 107-4
Running Closed 107-15 or 107-16 (air filter restriction detected)
Table 3
Diagnostic Summary for a "Normally Closed" Air Filter Restriction Switch
Engine Condition Switch State Active Diagnostic Code
Not running (key on) Closed Normal condition
Running Closed Normal Condition (no air filter restriction detected)
Not running (key on) Open 107-3
Running Open 107-15 or 107-16 (air filter restriction detected) Note: A 107-15 or a 107-16 diagnostic code indicates that the air inlet is restricted. Refer to Troubleshooting, "Inlet Air Is Restricted".During the following procedure, refer to the electrical schematic for the application.Complete the procedure in the order in which the steps are listed.
Table 4
Troubleshooting Test Steps Values Results
1. Check the "Air Filter Restriction Switch Configuration"
A. Turn the keyswitch to ON.
B. Connect the electronic service tool to the diagnostic connector.
C. Under "Configuration Parameters", check the "Air Filter Restriction Switch Configuration".
Note: If the type of switch cannot be identified using the electronic service tool, contact the Dealer Solutions Network (DSN) for the information.
Air Filter Restriction Switch Configuration
Results : The switch is configured to "Normally Open".
Proceed to Test Step 2.
Results : The switch is configured to "Normally Closed".
Proceed to Test Step 3.
2. Check the Air Filter Restriction Switch
A. Turn the keyswitch to OFF.
B. Disconnect the air filter restriction switch from the wiring harness connector.
C. Turn the keyswitch to ON.
D. Monitor the electronic service tool for active fault codes.
Diagnostic codes
Results : There is not an active 107-3 diagnostic code. A failed air filter restriction switch has been detected.
Repair : Replace the air filter restriction switch.
Verify that the repairs eliminated the issue. Return the machine to service.
Results : There is an active 107-3 diagnostic code. A short circuit in the wiring harness has been detected.
Repair : Repair or replace the wiring harness.
Verify that the repair has eliminated the issue.
If the fault is still present, contact the Dealer Solutions Network (DSN).
3. Check the Air Filter Restriction Switch
A. Turn the keyswitch to OFF.
B. Disconnect the air filter restriction switch from the wiring harness connector.
C. Install a jumper wire in the wiring harness connector between the signal and ground terminals.
D. Turn the keyswitch to ON.
E. Monitor the electronic service tool for active fault codes.
Diagnostic codes
Results : There is not an active 107-3 diagnostic code. A failed air filter restriction switch has been detected.
Repair : Replace the air filter restriction switch.
Verify that the repairs eliminated the issue. Return the machine to service.
Results : There is an active 107-3 diagnostic code. An open circuit in the wiring harness has been detected.
Repair : Repair or replace the wiring harness.
Verify that the repair has eliminated the issue.
If the fault is still present, contact the Dealer Solutions Network (DSN).
Parts decal JOHNSON:
0283819
0283785
0433208
0435643
0435643 DECAL SET, Johnson
J120TLAND, J120TLARC, J120TLATF, J125ESXENR, J125ESXERK, J125ESXETA, J140CXARC, J140CXATF, J140CXENM
0284353
0284353 DECAL SET, Evinrude
J120TLAND, J120TLARC, J120TLATF, J125ESXENR, J125ESXERK, J125ESXETA, J140CXARC, J140CXATF, J140CXENM
0437168
0284877
0348688