0315958 EXH.HSG.,Inner lower,long JOHNSON
50ES71S, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, J50BECIC, J50BECNR, J50ECSR, J55RCIM, J55RLCSA, J60ECIA, J60ECNM, J60ECSR
EXH
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- EXHAUST HOUSING » 0315958
50ES73R, 50ESL73R, 50R73R, 50RL73R 1973
50ES74M, 50ESL74M 1974
50ES75B, 50ESL75B 1975
50R79C, 50RL79C 1979
55E76E, 55EL76E 1976
55E77D, 55EL77D 1977
55E78S, 55EL78S 1978
55E79C, 55EL79C 1979
J50BECIC, J50BELCIC 1981
J50BECNR, J50BELCNR 1982
J50ECSR, J50ELCSR 1980
J55RCIM, J55RLCIM 1981
J55RLCSA 1980
J60ECIA, J60ECIH, J60ELCIA, J60ELCIH, J60TLCIA, J60TLCIH 1981
J60ECNM, J60ELCNM, J60TLCNM 1982
J60ECSR, J60ELCSR 1980
Information:
Table 1
Diagnostic Trouble Codes    
J1939 Code    CDL Code    Code Description    Comments    
3511-11     3482-11     Sensor Supply #3:Other Failure Mode     High or low battery voltage supply has been detected on the 5V supply to the DEF pump.    
Follow the troubleshooting procedure in order to identify the root cause of the problem.    Note: 372-5260 Test Kit is required for completing this procedure.
Illustration 1 g03196836
Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Check the DEF Pump Pressure Sensor Supply Circuit for Excessive Voltage
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Diesel Exhaust Fluid Controller (DCU).
B. Disconnect the Pump Electronic Tank Unit (PETU) harness from the DEF pump.
C. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
D. Turn the keyswitch ON.
E. Measure the voltage between the 5V SUPPLY (Terminal 2) at the DEF pump connector and a known good ground source.
   
Supply Voltage    
Result: The voltage is greater than 5V.
Proceed to Test Step 3.
Result: The voltage is 5V or less.
Proceed to Test Step 2.
   
2. Check the DEF Pump Pressure Sensor Supply for a Short Circuit to Ground
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5056 Break-out Connector to the DEF pump connector.
The 398-5056 Break-out Connector must be used to prevent damage to the DEF pump connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 2 at the DEF pump connector) and a known good ground source.
   
Short Circuit    
Result: There was more than 100K ohms of resistance between the 5V SUPPLY and a ground source.
Proceed to Test Step 4.
Result: There was less than 100K ohms of resistance between the 5V SUPPLY and a ground source.
Repair: A short circuit to ground has been detected. Repair or replace the wiring harness.
Proceed to Test Step 4.
   
3. Check the DEF Pump Supply for a Pin-to Pin Short Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5063 Break-out Connector to the DCU connector.
The 398-5063 Break-out Connector must be used to prevent damage to the DCU connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 19 at the DCU connector) and all other pins in the DCU 86 pin connector.
   
Short Circuit    
Result: There was more than 100K ohms of resistance between the 5V SUPPLY and all other pins in the DEF pump connector.
Proceed to Test Step 4.
Result: There was less than 100K ohms of resistance between the 5V Supply and all other pins in the DEF pump connector.
Repair: There is a problem in the wiring harness. Repair or replace the wiring harness.
Proceed to Test Step 4.
   
4. Perform a DEF Dosing System Verification Test
A. Turn the keyswitch to the "ON" position. Do not start the engine.
B. Connect to the "Diesel Exhaust Fluid Controller #1 ECM" using Cat ET.
C. Perform the "DEF Dosing System Verification Test" .
   
Diagnostic Codes    
Result: The code did not return.
Return the unit to service.
Result: The code returned.
Repair: A failed DEF pump has been detected. Replace the DEF pump.
Perform the DEF Dosing Verification Test to verify that the issue has been resolved.
   
Parts exh JOHNSON:
0315954
0315954 EXH.HOUSING,Inner upper
50ES71S, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 50R79C, 55E76E, 55E78S, 55E79C, J50BECIC, J50BECNR, J50ECSR, J55RCIM, J55RLCSA, J60ECIA, J60ECNM, J60ECSR
0315957
0315957 EXH.HSG.,Inner lower,std
50ES71S, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, AM55RSLD, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J35AELCDE, J35AELCUD, J40ECDE, J40ECOB, J40ECRM, J40ECUD, J40WREES, J40WRLSIR, J40WRLSSC, J45RCCDS, J45RCCUC, J
0384267
0384266
0317519
0317520
0317932
0317932 EXH.HSG.,Outer,long
50ES73R, 50ES74M, 50R79C, 55E79C, J50BECIC, J55RCIM, J55RLCSA, J60ECIA, J60ECSR
0317931
0317931 EXH.HSG.,Outer,std.
50ES73R, 50ES74M, 50R79C, 55E79C, J45RCCDS, J45RCCUC, J45RCE, J45RCEIA, J45RCENM, J45RCESR, J45RCETB, J50BECIC, J55RCIM, J55RLCSA, J55RSLN, J55RWLCDC, J55RWLCOS, J55RWLCRD, J55RWLCUC, J55RWLE, J55RWLEIA, J55RWLENM, J55RWLESR, J55RWLETB, J60ECIA, J60E