0341689 FILTER, Overboard JOHNSON
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSSB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ90ELEDR, BJ90ELEUA, BJ90PLEEB, BJ90PLSSE, BJ90SLECM, J100WPLEEC, J100WPLSIF, J10
FILTER
Price: query
Rating:
Compatible models:
BJ115ELEDR
BJ115ELEUA
BJ115GLECM
BJ115PLEEM
BJ115PLSSB
BJ150ELECD
BJ150ELEDB
BJ150ELEUC
BJ175EXECD
BJ175EXEDB
BJ175EXEUC
BJ175PLEES
BJ175PLSIF
BJ175PLSSC
BJ90ELEDR
BJ90ELEUA
BJ90PLEEB
BJ90PLSSE
BJ90SLECM
J100WPLEEC
J100WPLSIF
J100WPLSSR
J100WQLECS
J105WELEEN
J105WELSIF
J105WELSSC
J105WRLEES
J105WRLSIF
J105WRLSSC
J115ELEOC
J150CXEES
J150CXSSC
J150ELEOM
J150JPLSIF
J150WPLEES
J150WPLSSC
J150WTLEOR
J175EXEOM
J90ELEOC
SJ105RWLH
SJ105RWLP
SJ105WELV
SJ150WTPLB
SJ150WTPLT
SJ150WTPLY
JOHNSON
BRP JOHNSON entire parts catalog list:
- CYLINDER & CRANKCASE » 0341689
BJ115GLECM, BJ115SXECM, HJ115SLECM, J115ELECM, J115GLECM, J115JTLECS, J115SLECM, J115SXECM 1998
BJ115PLEEM, BJ115PXEEM, J115JPLEEC, J115PLEEM, J115PXEEM, J115SPLEES 1999
BJ115PLSSB, BJ115PXSSB, BJ115VXSSS, J115JPLSSR, J115PLSSB, J115PXSSB, J115SPLSSC, J115VLSSS, J115VXSSS, RJ115PLSSB, RJ115PXSSB, RJ115VLSSB, RJ115VXSSS 2000
BJ150ELECD, BJ150EXECD, BJ150GLECD, BJ150NXECD, J150ELECD, J150EXECD, J150GLECD, J150JLECD, J150NXECD, J150SLECD 1998
BJ150ELEDB, BJ150EXEDB, BJ150GLEDB, BJ150NXEDB, J150ELEDB, J150EXEDB, J150GLEDB, J150JLEDB, J150NXEDB, J150SLEDB, SJ150ELEDB 1996
BJ150ELEUC, BJ150ELEUE, BJ150EXEUC, BJ150EXEUE, BJ150GLEUC, BJ150GLEUE, BJ150NXEUC, BJ150NXEUE, J150ELEUC, J150ELEUE, J150EXEUC, J150EXEUE, J150GLEUC, J150GLEUE, J150JLEUC, J150JLEUE, J150NXEUC, J150NXEUE, J150SLEUC, J150SLEUE 1997
BJ175EXECD, BJ175GLECD, BJ175NXECD, J175EXECD, J175GLECD, J175NXECD, J175SLECD 1998
BJ175EXEDB, BJ175GLEDB, BJ175NXEDB, J175EXEDB, J175GLEDB, J175NXEDB, J175SLEDB 1996
BJ175EXEUC, BJ175EXEUE, BJ175GLEUC, BJ175GLEUE, BJ175NXEUC, BJ175NXEUE, J175EXEUC, J175EXEUE, J175GLEUC, J175GLEUE, J175NXEUC, J175NXEUE, J175SLEUC, J175SLEUE 1997
BJ175PLEES, BJ175PXEES, J175CXEES, J175PLEES, J175PXEES, J175SPLEES 1999
BJ175PLSIF, BJ175VXSIF, J175PLSIF, J175VCXSIF, J175VLSIF, J175VXSIF, RJ175CXSIF, RJ175PLSIF, RJ175VXSIF 2001
BJ175PLSSC, BJ175PXSSC, BJ175VXSSS, J175CXSSS, J175PLSSC, J175PXSSC, J175SPLSSC, J175VCXSSS, J175VLSSS, J175VXSSS, RJ175CXSSS, RJ175PLSSC, RJ175VXSSS 2000
BJ90ELEDR, BJ90SLEDR, J90ELEDR, J90SLEDR, SJ90ELEDR 1996
BJ90ELEUA, BJ90ELEUC, BJ90SLEUA, BJ90SLEUC, BJ90SXEUA, BJ90SXEUC, J90ELEUA, J90ELEUC, J90SLEUA, J90SLEUC 1997
BJ90PLEEB, BJ90PXEEB, J90PLEEB, J90SPLEES 1999
BJ90PLSSE, BJ90PXSSE, BJ90VXSSS, J90PLSSE, J90SPLSSC, J90VLSSE, RJ90PLSSE, RJ90VLSSS 2000
BJ90SLECM, BJ90SXECM, J90ELECM, J90SLECM 1998
J100WPLEEC, J100WPXEEC 1999
J100WPLSIF, J100WPXSIF 2001
J100WPLSSR, J100WPXSSR 2000
J100WQLECS, J100WQXECS 1998
J105WELEEN, J105WELEES, J105WPLEEN, J105WPLEES, J105WPXEEN, J105WPXEES 1999
J105WELSIF, J105WPLSIF, J105WPXSIF 2001
J105WELSSC, J105WPLSSC, J105WPXSSC 2000
J105WRLEES, J105WRYEES 1999
J105WRLSIF, J105WRYSIF 2001
J105WRLSSC, J105WRYSSC 2000
J115ELEOC, J115GLEOC, J115SLEOC, J115SXEOC 1995
J150CXEES, J150JPLEES, J150PLEES, J150PXEES, J150SPLEES 1999
J150CXSSC, J150JPLSSC, J150MXSSD, J150PLSSC, J150PXSSC, J150SPLSSC, J150VCSSS, J150VLSSS, J150VXSSS, RJ150CXSSC, RJ150PLSSC, RJ150PXSSC, RJ150VCSSS, RJ150VLSSS, RJ150VXSSS 2000
J150ELEOM, J150EXEOM, J150GLEOM, J150JLEOM, J150NXEOM, J150SLEOM, VJ150HLEOS 1995
J150JPLSIF, J150PLSIF, J150VCXSIF, J150VLSIF, J150VXSIF, RJ150PLSIF, RJ150VCSIF, RJ150VLSIF, RJ150VXSIF 2001
J150WPLEES 1999
J150WPLSSC 2000
J150WTLEOR, J150WTXEOR 1995
J175EXEOM, J175GLEOM, J175NXEOM, J175SLEOM 1995
J90ELEOC, J90EXEOC, J90SLEOC 1995
SJ105RWLH, SJ105RWYH 1998
SJ105RWLH, SJ105RWYH 1998
SJ105RWLP, SJ105RWYP 1997
SJ105RWLP, SJ105RWYP 1997
SJ105WELV, SJ105WEXV, SJ105WRPLV, SJ105WRPXV 1998
SJ105WELV, SJ105WEXV, SJ105WRPLV, SJ105WRPXV 1998
SJ150WTPLB, SJ150WTPXB 1996
SJ150WTPLT, SJ150WTPLT4, SJ150WTPXT, SJ150WTPXT4 1997
SJ150WTPLY, SJ150WTPXY 1998
Information:
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Note: Reclaim the refrigerant before any lines are loosened or any bolts are loosened.
Reclaim the refrigerant in the air conditioning system.Reference: Refer to Testing and Adjusting, "Refrigerant Recovery" for the correct procedure.
Illustration 1 g00940038
Open the side door (1) .
Illustration 2 g00705026
Disconnect two hose assemblies (3) from refrigerant condenser (2) .
Remove two bolts (5) and the clamps from the mounting bracket.
Remove two bolts (1), two washers, and two nuts from the mounting bracket.
Remove two bolts (4) and washers from refrigerant condenser (2) .
Illustration 3 g00705040
Remove four bolts (7) and washers from the two mounting brackets (6) .Installation Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Illustration 4 g00705040
Position two mounting brackets (6) onto the condenser. Install the washers and four bolts (7) .
Illustration 5 g00705026
Install washers and two bolts (4) to the refrigerant condenser (2) .
Install two nuts, two washers, and two bolts (1) to the mounting bracket.
Connect two hose assemblies (3) to refrigerant condenser (2) .
Install the clamps and two bolts (5) that hold hose assemblies (3) to the mounting bracket.
Illustration 6 g00940038
Close the side door (1) .
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other sm
Parts filter JOHNSON:
0174377
0174377 FILTER
CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM, J100STLCCA, J100STLCEM, J100STLEIE, J100STLEND, J100STLERC, J100STLESB, J100STLETS, J100WMLCDR, J100WMLCOC, J100WTLCUA, J100WTLEIB, J100WTLENE, J100WTLEOC, J100WTLERS, J100WTLESM, J100WTLETD,
0332365
0332365 FILTER, Valve housing
BJ10EEDD, BJ10FAEDC, BJ10FAEUR, BJ10FDLECM, BJ10FDLEDR, BJ10FDLEUA, BJ10RELEUS, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ
0337497
0337497 FILTER AY.
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF
0438624
0438624 FILTER
J105WELEEN, J105WELSIF, J105WELSSC, J105WPLSTM, J105WRLEES, J105WRLSIF, J105WRLSSC, J115WPLSOC, J115WPLSRS, J65RSLZ2, J65WRLEEO, J65WRLSIR, J65WRLSSC, SJ105RWLH, SJ105RWLH, SJ105RWLP, SJ105RWLP, SJ105WELV, SJ105WELV, SJ35RWECS, SJ65RSLD