0581751 JOHNSON FLYWHEEL ASSEMBLY


0581751 FLYWHEEL ASSEMBLY JOHNSON 25E77S, 35E77C FLYWHEEL
0581751 FLYWHEEL ASSEMBLY JOHNSON
Rating:
43

Buy FLYWHEEL ASSEMBLY 0581751 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$109.95
 

08-09-2017
10.00[4.50] pounds
OMC: OMC
0581751 0582167 Flywheel Evinrude Johnson Outboard 25 35 Hp 1977-1984 0582434
OMC||0581751||Used, teeth are in good condition||1977-1984||25-35hp
Number on catalog scheme: 2
 

Compatible models:

25E77S   35E77C   JOHNSON

BRP JOHNSON entire parts catalog list:

25E77S, 25EL77H, 25EL77S, 25R77H, 25R77S, 25RL77H, 25RL77S 1977
35E77C, 35E77H, 35EL77C, 35EL77H, 35R77C, 35R77H, 35RL77C, 35RL77H 1977

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
4215-3
Ground-Level Shutdown Activated : Voltage Above Normal 267-3
Remote Shutdown Input : Voltage Above Normal If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.
4215-4
Ground-Level Shutdown Activated : Voltage Below Normal 267-4
Remote Shutdown Input : Voltage Below Normal If both contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.
4215-31
Ground-Level Shutdown Activated E678 (1)
Ground Level Shutdown The inputs from the ground level shutdown switch to the Electronic Control Module (ECM) have changed states.
The engine will shut down. The code is logged.
4215-31
Ground-Level Shutdown Activated E678 (2)
Ground Level Shutdown The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged.
4215-31
Ground-Level Shutdown Activated E678 (3)
Ground Level Shutdown The inputs from the ground level shutdown switch to the ECM have changed states.
The engine will shut down. The code is logged. The shutdown switch will shut down the engine. The engine ECM remains active. Caterpillar® Electronic Technician (ET) can be used to communicate with the ECM. The shutdown switch must be returned to the RUN position before the ECM will allow the engine to start.The ECM reads the position of the shutdown switch. If the engine is running, the ECM disables the fuel injection. The status screen will display"Injection Disabled" and "Remote Shutdown".
Illustration 1 g03843822
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A E678 or 4215-31 code is active or logged.
Proceed to Test Step 2.
Result: A 267-3 or 4215-3 code is active or logged.
Proceed to Test Step 3.
Result: A 267-4 or 4215-4 code is active or logged.
Proceed to Test Step 4.
2. Check the Status of the Shutdown Switch on Cat ET
A. Activate the shutdown.
B. Connect Cat ET.
C. Use Cat ET to verify that the engine rpm is 0.
D. Return the shutdown switch to the RUN position.
E. Use Cat ET to monitor the status of the shutdown switch.
Switch Status
Result: The status of the shutdown switch changed states after returning the shutdown switch to the RUN position.
The shutdown switch is operating correctly. Return to service.
Result: The status of the shutdown switch does not change states after returning the shutdown switch to the RUN position.
Proceed to Test Step 3.
3. Create a Short at the Connector for the Shutdown Switch
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the shutdown switch.
C. Create a short circuit between the following terminals at the shutdown switch connector:
- Terminal 1 and Terminal 2
D. Turn the keyswitch to the ON position.
E. Connect Cat ET.
F. Use Cat ET to monitor the status of the shutdown switch.
G. Remove the wire short.
Create a Short
Result: The status of the shutdown switch changed states after creating the short circuit.
Repair: Install a new shutdown switch.
Verify that the repair eliminated the problem.
Result: The status of the shutdown switch did not change states after creating the short circuit.
Repair: Repair or replace the wiring harness.
Verify that the repair eliminated the problem.
4. Create an Open at the Connector for the Shutdown Switch
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the shutdown switch.
C. Turn the keyswitch to the ON position.
D. Connect Cat ET.
E. Use Cat ET to monitor the status of the shutdown switch.
Create an Open
Result: The status of the shutdown switch changed states after creating the open circuit.
Repair: Install a new shutdown switch.
Verify that the repair eliminated the problem.
Result: The status of the shutdown switch did not change states after creating the open circuit.
Repair: Repair or replace the wiring harness.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Parts flywheel JOHNSON:

0581749
 
0581749 FLYWHEEL ASSEMBLY
25E77S, 35E77C
Back to top