0310473 GASKET, Solenoid to housing JOHNSON
40E69R, 40E70A, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, RDS-30A, RK-30A
GASKET
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BRP JOHNSON entire parts catalog list:
- CARBURETOR GROUP ELECTRIC START » 0310473
40E72E, 40EL72E, 40R72E, 40RL72E 1972
40E73D, 40EL73D, 40R73D, 40RL73D 1973
40E74S, 40EL74S, 40R74S, 40RL74S 1974
40E75C, 40EL75C, 40R75C, 40RL75C 1975
40E76A, 40E76R, 40EL76A, 40EL76R, 40R76A, 40R76R, 40RL76A, 40RL76R 1976
40ES69R, 40ESL69R 1969
40ES70A, 40ESL70A 1970
RDS-30A, RDS-30C, RDS-30D, RDS-30S, RDSL-30A, RDSL-30C, RDSL-30D, RDSL-30S 1968
RK-30A, RK-30C, RK-30D, RKL-30A, RKL-30C, RKL-30D 1968
Information:
SEBE7587
April 5, 2001
U-81
Safety CHECK THE TORQUE OF THE TERMINAL LUG SCREWS ON THE RADIATOR FAN MOTOR CONTACTOR AND MOTOR RELAY ON CERTAIN PM3516B AND 3516B GENERATOR SET ENGINES
7272 PI10067
This Program must be administered as soon as possible. When reporting the repair, use "PI10067" as the Part number and "7751" as the Group Number, "56" as the Warranty Claim Description Code and "T" as the SIMS Description Code. Exception: If the repair is done after failure, use "PI10067" as the Part Number, "7751" as the Group Number, "96" as the Warranty Claim Description Code, and "Z" as the SIMS Description Code.
PROBLEM
The radiator fan motor contactor and the motor relay may have been assembled and installed without the proper torque on the terminal lug screws. Lug screws can loosen without proper torque, during normal operation, causing an increase in electrical resistance that could result in a severe electrical hazard and component failure.
AFFECTED PRODUCT
Model Identification Number
PM3516B BPD142, 149-162, 164, 179-180
3516B 6HN832, 835, 838
7RN1166, 1174, 1178-1182, 1184, 1186, 1201, 1209-1211, 1213, 1220, 1224, 1228, 1231, 1236, 1237, 1241-1242, 1246, 1260, 1282, 1284, 1293, 1298-1299, 1306, 1310-1311, 1316-1317, 1319, 1325, 1327-1328, 1342, 1392, 1397, 1403, 1407, 1413-1415, 1417-1421, 1423, 1428-1429, 1431-1432, 1435, 1440-1443, 1445, 1450-1460, 1463, 1468, 1474, 1476, 1478, 1482-1483, 1488, 1490, 1499, 1502, 1505, 1508-1509, 1512-1514, 1516-1517, 1520-1524, 1527, 1531-1535, 1537-1538, 1542-1550, 1553-1554, 1557-1558, 1562, 1571, 1584-1589, 1593, 1595, 1597-1598, 1600-1601, 1603-1606, 1609-1610, 1614, 1618-1626, 1629-1631, 1634, 1637-1638, 1641-1642, 1644-1645, 1648-1649, 1651-1661, 1678, 1691-1692, 1697-1698, 1705, 1715, 1722-1724, 1728
PARTS NEEDED
No Parts Needed
ACTION REQUIRED
See the attached Rework Procedure.
OWNER NOTIFICATION
U.S. and Canadian owners will receive the attached Owner Notification.
SERVICE CLAIM ALLOWANCES
Caterpillar Dealer Suggested Customer Suggested
Parts Labor Hrs. Parts Labor Hrs. Parts Labor Hrs.
100% 1 0 0 0 0
This is a 1.0- hour job.
U.S. and Canadian Dealers Only - Eligible dealers may enter a Type 2 SIMS ReportPARTS DISPOSITION
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling.
MAKE EVERY EFFORT TO COMPLETE THIS PROGRAM AS SOON AS POSSIBLE.
Attach. (1-Owner Notification)
(2-Rework Procedure)
COPY OF OWNER NOTIFICATION FOR U.S. AND CANADIAN OWNERS
XYZ Corporation
3240 Arrow Drive
Anywhere, YZ 99999
Safety ? CHECK TORQUE ON TERMINAL LUG SCREWS FOR FAN MOTOR CONTACTOR AND MOTOR RELAY
MODELS INVOLVED ? CERTAIN 3516B GENERATOR SETS
Dear Caterpillar Product Owner:
The terminal lug screws for the fan motor contactor and the motor relay must be checked for proper torque on the products listed below. Without proper torque, terminal lug screws can loosen during normal operation, which can result in a severe electrical hazard and component failure, with the risk for shock or fire. You will not be charged for the service performed.
Contact your local Caterpillar dealer immediately to schedule this service. The dealer will advise you of the time required to complete this service. Please refer the dealer to their Service Letter dated April 5, 2001 when scheduling this service.
We regret the inconvenience this may cause you, but urge you to have this service performed for your added safety and satisfaction.
Caterpillar Inc.
Identification #(s)
Attached to April 5, 2001 Service Letter
Rework Procedure
Turn off all supply power, prevent the engine from starting and lock out the equipment before working on or inside equipment.
Qualified electrical personnel only should perform this service.
To confirm that power is off, use a properly rated device that senses voltage.
Locate and identify the radiator motor control circuit breaker and its contactor. It is installed either in the wall mounted radiator fan motor control panel or inside the utility cubicle, in units equipped with the floor standing utility switch-gear.
Insert a small flat top screwdriver into the plastic tabs and pry out the intermediate terminal lug screw cover. These screws are located on the top of the Siemens brand relay (1912306) and bottom of the Siemens brand contactor (1912305) and create an electrical junction for phase connections and also support the relay assembly on the contactor.
Tighten the lug terminal screws to 70 lb-in using a 10mm socket wrench.
Replace all devices, doors and covers before turning power on to this equipment.
NOTE: It is recommended to check and torque the cable terminal lug screws on the bottom of the relay and top of the contactor to 70 lb-in, as these should be periodically inspected and the torque checked during normal maintenance. Identify the type of motor circuit breaker in this fan motor circuit, if it is a Siemens brand circuit breaker part number, 1912307, replace it with the circuit breaker, 2029033, under program PI10050.
April 5, 2001
U-81
Safety CHECK THE TORQUE OF THE TERMINAL LUG SCREWS ON THE RADIATOR FAN MOTOR CONTACTOR AND MOTOR RELAY ON CERTAIN PM3516B AND 3516B GENERATOR SET ENGINES
7272 PI10067
This Program must be administered as soon as possible. When reporting the repair, use "PI10067" as the Part number and "7751" as the Group Number, "56" as the Warranty Claim Description Code and "T" as the SIMS Description Code. Exception: If the repair is done after failure, use "PI10067" as the Part Number, "7751" as the Group Number, "96" as the Warranty Claim Description Code, and "Z" as the SIMS Description Code.
PROBLEM
The radiator fan motor contactor and the motor relay may have been assembled and installed without the proper torque on the terminal lug screws. Lug screws can loosen without proper torque, during normal operation, causing an increase in electrical resistance that could result in a severe electrical hazard and component failure.
AFFECTED PRODUCT
Model Identification Number
PM3516B BPD142, 149-162, 164, 179-180
3516B 6HN832, 835, 838
7RN1166, 1174, 1178-1182, 1184, 1186, 1201, 1209-1211, 1213, 1220, 1224, 1228, 1231, 1236, 1237, 1241-1242, 1246, 1260, 1282, 1284, 1293, 1298-1299, 1306, 1310-1311, 1316-1317, 1319, 1325, 1327-1328, 1342, 1392, 1397, 1403, 1407, 1413-1415, 1417-1421, 1423, 1428-1429, 1431-1432, 1435, 1440-1443, 1445, 1450-1460, 1463, 1468, 1474, 1476, 1478, 1482-1483, 1488, 1490, 1499, 1502, 1505, 1508-1509, 1512-1514, 1516-1517, 1520-1524, 1527, 1531-1535, 1537-1538, 1542-1550, 1553-1554, 1557-1558, 1562, 1571, 1584-1589, 1593, 1595, 1597-1598, 1600-1601, 1603-1606, 1609-1610, 1614, 1618-1626, 1629-1631, 1634, 1637-1638, 1641-1642, 1644-1645, 1648-1649, 1651-1661, 1678, 1691-1692, 1697-1698, 1705, 1715, 1722-1724, 1728
PARTS NEEDED
No Parts Needed
ACTION REQUIRED
See the attached Rework Procedure.
OWNER NOTIFICATION
U.S. and Canadian owners will receive the attached Owner Notification.
SERVICE CLAIM ALLOWANCES
Caterpillar Dealer Suggested Customer Suggested
Parts Labor Hrs. Parts Labor Hrs. Parts Labor Hrs.
100% 1 0 0 0 0
This is a 1.0- hour job.
U.S. and Canadian Dealers Only - Eligible dealers may enter a Type 2 SIMS ReportPARTS DISPOSITION
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling.
MAKE EVERY EFFORT TO COMPLETE THIS PROGRAM AS SOON AS POSSIBLE.
Attach. (1-Owner Notification)
(2-Rework Procedure)
COPY OF OWNER NOTIFICATION FOR U.S. AND CANADIAN OWNERS
XYZ Corporation
3240 Arrow Drive
Anywhere, YZ 99999
Safety ? CHECK TORQUE ON TERMINAL LUG SCREWS FOR FAN MOTOR CONTACTOR AND MOTOR RELAY
MODELS INVOLVED ? CERTAIN 3516B GENERATOR SETS
Dear Caterpillar Product Owner:
The terminal lug screws for the fan motor contactor and the motor relay must be checked for proper torque on the products listed below. Without proper torque, terminal lug screws can loosen during normal operation, which can result in a severe electrical hazard and component failure, with the risk for shock or fire. You will not be charged for the service performed.
Contact your local Caterpillar dealer immediately to schedule this service. The dealer will advise you of the time required to complete this service. Please refer the dealer to their Service Letter dated April 5, 2001 when scheduling this service.
We regret the inconvenience this may cause you, but urge you to have this service performed for your added safety and satisfaction.
Caterpillar Inc.
Identification #(s)
Attached to April 5, 2001 Service Letter
Rework Procedure
Turn off all supply power, prevent the engine from starting and lock out the equipment before working on or inside equipment.
Qualified electrical personnel only should perform this service.
To confirm that power is off, use a properly rated device that senses voltage.
Locate and identify the radiator motor control circuit breaker and its contactor. It is installed either in the wall mounted radiator fan motor control panel or inside the utility cubicle, in units equipped with the floor standing utility switch-gear.
Insert a small flat top screwdriver into the plastic tabs and pry out the intermediate terminal lug screw cover. These screws are located on the top of the Siemens brand relay (1912306) and bottom of the Siemens brand contactor (1912305) and create an electrical junction for phase connections and also support the relay assembly on the contactor.
Tighten the lug terminal screws to 70 lb-in using a 10mm socket wrench.
Replace all devices, doors and covers before turning power on to this equipment.
NOTE: It is recommended to check and torque the cable terminal lug screws on the bottom of the relay and top of the contactor to 70 lb-in, as these should be periodically inspected and the torque checked during normal maintenance. Identify the type of motor circuit breaker in this fan motor circuit, if it is a Siemens brand circuit breaker part number, 1912307, replace it with the circuit breaker, 2029033, under program PI10050.
Parts gasket JOHNSON:
0304764
0304764 GASKET,Bushing
20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 33E70M, 35E77C, 35E78R, 35E79A, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40
0304169
0304169 GASKET,Lower front mount
20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 33E70M, 35E76G, 35E77C, 35E78R, 35E79A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, FD-22A, J4
0311365
0311365 GASKET,Leaf plate to crankcase
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, RD-30A, RDS-30A, RK-30A, RX-16M
0311364
0311364 GASKET,Leaf plate to manifold
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, RD-30A, RDS-30A, RK-30A, RX-16M
0303750
0303750 GASKET,Carb.body to bowl
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, RD-30A, RDS-30A, RK-30A, RX-16M
0309170
0310387
0310387 GASKET, Carburetor to manifold
40E69R, 40E70A, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, RD-30A, RDS-30A, RK-30A
0305198
0305198 GASKET, Thermostat hsg.
40E69R, 40E70A, 40ES69R, 40ES70A, 40R69R, 40R70A, RD-30A, RDS-30A, RK-30A