5031297 JOHNSON GASKET, CYL HEAD COVER


5031297 GASKET, CYL HEAD COVER JOHNSON BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC GASKET
5031297 GASKET, CYL HEAD COVER JOHNSON
Rating:
58

Buy GASKET, CYL HEAD COVER 5031297 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 12
 

BRP JOHNSON entire parts catalog list:

BJ40PL4SDR, J40PL4SDE 2006
BJ40PL4SOC, J40PL4SOB 2005
BJ40PL4SRS, J40PL4SRM 2004
BJ50PL4SDR, J50PL4SDE 2006
BJ50PL4SOC, J50PL4SOB 2005
BJ50PL4SRS, J50PL4SRM 2004
J40PL4SNF 2002
J40PL4STC 2003
J50PL4SNF 2002
J50PL4STC 2003

Information:


Table 1
Required Tools
Tool Part Number Part Description Qty
A - Bellows Protector 1
Wear goggles, gloves, protective clothing, and a National Institute for Occupational Safety and Health (NIOSH) approved P95 or N95 half-face respirator when handling a used Diesel Particulate Filter or Catalytic Converter Muffler. Failure to do so could result in personal injury.
Do not strike any part of the assembly of the Diesel Particulate Filter (DPF). Do not allow any object to contact the internal element of the DPF. If the internal element of the DPF becomes damaged, the assembly must be replaced.
Ensure that all components are clean and free from wear and damage. If necessary, replace any components that are worn or damaged. Refer to Disassembly and Assembly, "Inspection of Parts" for the correct procedures.
If the flexible exhaust pipe was removed as an assembly, refer to Disassembly and Assembly, "Flexible Exhaust Pipe - Remove and Install" for the correct installation procedure.
Illustration 1 g03372061
Illustration 2 g03372062
If necessary, install the temperature sensors (3) and temperature sensor (9) into the DPF. Refer to Disassembly and Assembly, "Temperature Sensor (DPF) - Remove and Install" for the correct procedure.
Position a new V-band clamp onto flexible exhaust pipe (12).
Attach a suitable lifting device to the assembly of the Diesel Particulate Filter (DPF) (4). The weight of the DPF is approximately 15 kg (33 lb).
Use the suitable lifting device in order to install the DPF to mounting bracket (10). Ensure that the flexible exhaust pipe is correctly seated onto the turbocharger and DPF with the alignment pin (not shown) fully engaged. Note: Ensure that the exhaust gases flow in the direction of temporary mark.
Remove the suitable lifting device from the assembly of the DPF.
Position clamps (5) onto DPF (4). Loosely install bolts (8).
Loosely install the Original Equipment Manufacturer's (OEM) exhaust pipe assembly to outlet section (6) of the DPF.
Align the temporary alignment marks on DPF (4) and clamps (5) in Positions (A), (B), (C) and (D). Note: Ensure that the flexible exhaust pipe bellows are not subjected to any undue stress.
If a new DPF is being installed, the DPF must be aligned using flexible exhaust pipe (12) as the reference point. Note: Ensure that the flexible exhaust pipe bellows are not subjected to any undue stress.
Position the V-band clamp onto the DPF. Tighten the flexible exhaust pipe clamp. Refer to Disassembly and Assembly, "Flexible Exhaust Pipe - Remove and Install" for the correct procedure.
Tighten the OEM exhaust pipe assembly to the outlet section of the DPF. Refer to the OEM for the correct procedure.
Ensure that the DPF is installed in the original position and all of the temporary alignment marks are aligned. Note: Ensure that the flexible exhaust pipe bellows are not subjected to any undue stress.
Tighten bolts (8) evenly in three stages. Tighten bolts (8) to an initial torque of 8 N m (71 lb in)Tighten bolts (8) to a secondary torque of 16 N m (141.6 lb in)Tighten bolts (8) to a final torque of 25 N m (221 lb in).
If necessary, remove Tooling (A) from flexible exhaust pipe (12). Note: Do not start the engine with the bellows protector in place.
Connect the wiring harness assembly to connection (1) on temperature sensor (2).
Connect the wiring harness assembly to connection (11) on temperature sensor (3).
Connect the pressure sensor tube assembly (9) to the DPF. Tighten the connection to a torque of 30 N m (265 lb in).
Connect the pressure sensor tube assembly (7) to the DPF. Tighten the connection to a torque of 30 N m (265 lb in). End By:
If the DPF has had an ash service, it will be necessary to use the electronic service tool in order to perform the "DPF Ash Cleaning" procedure.
If the DPF required replacing and a new DPF has been installed, it will be necessary to use the electronic service tool in order to perform the "DPF Replacement Reset" procedure.


Parts gasket JOHNSON:

5030071
GASKET, Drain & fill plug
5030071 GASKET, Drain & fill plug
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA,
5030623
 
5030623 GASKET, Anode cover
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4S
5031293
GASKET, CYLINDER HEAD
5031293 GASKET, CYLINDER HEAD
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5031296
 
5031296 GASKET, SPARK PLUG HOLE
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5031302
 
5031302 GASKET SET
BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SOC, BJ50PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5031419
 
5031419 GASKET, PUMP CASE UNDER
BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SOC, BJ50PL4SRS, J25PL4SOC, J25PL4SRS, J30PL4SOC, J30PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5036681
GASKET, Plate
5036681 GASKET, Plate
BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ50PL4SDR, J30PL4SDR, J30PL4SUA, J30TEL4SDR, J30TEL4SUA
5036714
 
5036714 GASKET SET
BJ40PL4SDR, BJ50PL4SDR
Back to top