0318401 JOHNSON GROMMET, Remote cont cable


0318401 GROMMET, Remote cont cable JOHNSON 65ES73R, 70EL76D, 70EL77S, 70EL78C, 70EL79R, 70ES74M, 70ES75B, 75ELR76D, 75ELR77S, 75ELR78C, 75ELR79R, 75ESLR75B, BJ50DTLEDC, BJ50DTLEUR, BJ60ELEDR, BJ60ELEUA, BJ60TLECM, BJ70ELECB, BJ70ELEDA, BJ70ELEUM, BJ70PLEEE, BJ70PLSIS, BJ70PLSSD, J40JPLEEC, J4 GROMMET
0318401 GROMMET, Remote cont cable JOHNSON
Rating:
79

Buy GROMMET, Remote cont cable 0318401 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 56
 

BRP JOHNSON entire parts catalog list:

65ES73R, 65ESL73R 1973
70EL76D 1976
70EL77S 1977
70EL78C 1978
70EL79R 1979
70ES74M, 70ESL74M, 70ESLR74M 1974
70ES75B, 70ES75E, 70ESL75B, 70ESL75E 1975
75ELR76D, 75ER76D 1976
75ELR77S, 75ER77S 1977
75ELR78C, 75ER78C 1978
75ELR79R, 75ER79R 1979
75ESLR75B, 75ESR75B 1975
BJ50DTLEDC, J50DTLEDC, J50ELED 1996
BJ50DTLEUR, J50DTLEUR, J50ELEUR 1997
BJ60ELEDR, BJ60TLEDR, J60ELEDR, J60TLEDR, SJ60TLEDR 1996
BJ60ELEUA, BJ60TLEUA, J60ELEUA, J60TLEUA 1997
BJ60TLECM, J60TLECM 1998
BJ70ELECB, BJ70TLECB, J70TLECB 1998
BJ70ELEDA, BJ70TLEDA, HJ70TXEDA, J70TLEDA, SJ70TLEDA 1996
BJ70ELEUM, BJ70TLEUM, HJ70TXEUM, J70TLEUM 1997
BJ70PLEEE, J70PLEEE 1999
BJ70PLSIS, J70PLSIS, J70VLSIS, RJ70PLSIS 2001
BJ70PLSSD, J70PLSSD, RJ70PLSSD 2000
J40JPLEEC 1999
J40JPLSIA, J40JVLSIA 2001
J40JPLSSR 2000
J50DTLECA 1998
J50DTLEOS, J50ELEOS 1995
J60ELCCR, J60TLCCR, J60TTLCCR 1988
J60ELCDS, J60TLCDS 1986
J60ELCEA, J60TLCEA, J60TTLCEA, TJ60TLCEA, TJ60TLESF 1989
J60ELCUC, J60TLCUC 1987
J60ELEIB, J60TLEIB, TJ60TLEIB, VJ60ELEIB, VJ60TLEIB 1991
J60ELENE, J60TLENE, TJ60TLENE, VJ60ELENE, VJ60TLENE 1992
J60ELEOC, J60TLEOC 1995
J60ELERS, J60ELERV, J60TLERS, J60TLERV 1994
J60ELESM, J60TLESM, J60TTLESM, TJ60TLESF, TJ60TLESM, VJ60ELESM, VJ60TLESM 1990
J60ELETD, J60TLETD, TJ60TLETD, VJ60ELETD 1993
J60PLEEB 1999
J60PLSID, J60VLSID 2001
J60PLSSE 2000
J65RWLCRS, J65TELCRS, J65WTLCRS 1984
J65WELEES 1999
J65WELSIR 2001
J65WELSSC 2000
J65WMLCDR 1986
J65WMLCOC, J65WTLCOC 1985
J65WMLCUA 1987
J65WMLEIB 1991
J65WMLENE 1992
J65WMLEOC 1995
J65WMLERS 1994
J65WMLESM 1990
J65WMLETD 1993
J65WMLZ 1989
J70ELCCA, J70TLCCA 1988
J70ELCDC, J70TLCDC 1986
J70ELCEM, J70TLCEM, TJ70TLCEM, TJ70TLESF 1989
J70ELCIH, J70ELCIM, J70TLCIM 1981
J70ELCNB, J70TLCNB 1982
J70ELCOS, J70TLCOS 1985
J70ELCRD, J70TLCRD 1984
J70ELCSA 1980
J70ELCTE, J70TLCTE 1983
J70ELCUR, J70TLCUR 1987
J70ELEIE, J70TLEIE, VJ70ELEIE, VJ70TLEIE 1991
J70ELEND, J70TLEND, VJ70ELEND, VJ70TLEND 1992
J70ELEOR, J70JLEOS, J70TLEOR 1995
J70ELERC, J70ELERV, J70TLERC, J70TLERV 1994
J70ELESB, J70TLESB, TJ70TLESB, TJ70TLESF, VJ70ELESB, VJ70TLESB 1990
J70ELETS, J70TLETS, VJ70ELETS, VJ70TLETS 1993
J75ECCA 1988
J75ECDC 1986
J75ECNB, J75ELCNB, J75TLCNB 1982
J75ECOS 1985
J75ECRD, J75ELCRD, J75TLCRD 1984
J75ECTE, J75ELCTE, J75TLCTE 1983
J75ECUR 1987
J75ERCIH, J75ERCIM, J75ERLCIH, J75ERLCIM, J75TELCIM, J75TRLCIH 1981
J75ERCSA, J75ERLCSA, J75TRLCSA 1980
N65WMLM 1988
SJ65WMLD, SJ65WMYD 1998
SJ65WMLM, SJ65WMYM 1996
SJ65WMLZ2, SJ65WMYZ2 1997

Information:


Table 1
Diagnostic Trouble Codes for the Circuit for the EFLP Relay    
J1939 Code    Description    Notes    
1075-5     Engine Electric Lift Pump for Engine Fuel supply: Current Below Normal     The Electronic Control Module (ECM) detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is not attempting to power the relay.
The ECM has been powered for at least 2 seconds.
There is a low current condition in the fuel lift pump relay circuit for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the fuel lift pump. The fuel lift pump will not operate or the fuel lift pump will operate all the time. The engine will not operate.    
1075-6     Engine Electric Lift Pump for Engine Fuel supply: Current Above Normal     The ECM detects the following conditions:
There are no active 168 diagnostic codes.
The ECM is attempting to power the relay.
The ECM has been powered for at least 2 seconds.
There is a high current condition in the fuel lift pump relay circuit for more than 2 seconds.
The warning light will come on. The diagnostic code will be logged.
The ECM is unable to activate the relay for the fuel lift pump. The fuel lift pump will not operate or the fuel lift pump will operate all the time. The engine will not operate.
The ECM will continue to attempt to activate the relay. If the current is OK for 6 seconds, then the diagnostic code will be cleared.    The following background information is related to this procedure:The EFLP is used in order to provide positive fuel pressure to the high-pressure fuel pump. When the keyswitch is turned to the ON position, the ECM will activate the relay for the EFLP. If the engine is not running, the ECM will deactivate the relay for the EFLP after 2 minutes.
Illustration 1 g02454517
Schematic for the Electric Fuel Lift Pump (EFLP)
Illustration 2 g02454536
View of the pin location on the P1 connector for the EFLP (36) Relay for the EFLPTest Step 1. Inspect Electrical Connectors and Wiring
Check that the fuses are not blown.
Check the harness for abrasion and pinch points from the Electric Fuel Lift Pump (EFLP) back to the ECM. Check the harness for abrasion and pinch points from the EFLP back to the battery.
Inspect the terminals on the EFLP relay and then inspect the harness connector for the relay. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Inspect the connector for the EFLP. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the EFLP.
Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).Results:
All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points. The fuses are not blown - Proceed to Test Step 2.
There is a fault with the harness and connectors - Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all of the seals are correctly in place and ensure that the connectors are correctly connected. Replace blown fuses.
Turn the keyswitch to the ON position. Do not start the engine. Check for active diagnostic codes.
Wait for at least 2 minutes for the EFLP to deactivate. Check for active diagnostic codes.
Confirm that the fault has been eliminated.Note: If a fuse is replaced and the fault reoccurs, continue with this procedure.STOPTest Step 2. Check for Active Diagnostic Codes
Connect the electronic service tool to the diagnostic connector.
Turn the keyswitch to the ON position.Note: Do not start the engine.
Make a note of any active diagnostic codes.
Wait for at least 2 minutes for the Electric Fuel Lift Pump (EFLP) to deactivate.
Make a note of any active diagnostic codes.Results:
Diagnostic code 1075-5 is active when the EFLP is switched off. - Proceed to Test step 3.
Diagnostic code 1075-6 is active when the EFLP is switched on. - Proceed to Test Step 5.
An active diagnostic code or a recently logged diagnostic code was not displayed. - There may be a fault with the switched power circuit for the EFLP. The ECM does not monitor the status of this condition. Proceed to Test Step 9.Test Step 3. Create a Short Circuit at the Fuel Lift Pump Relay
Turn the keyswitch to the OFF position.
Disconnect the connector for the Electric Fuel Lift Pump (EFLP) relay.
Fabricate a jumper wire that is 150 mm (6 inch) long.
Use the jumper wire to connect Test Point 1 to Test point 2 on the harness connector for the EFLP relay. Refer to Illustration 1.
Turn the keyswitch to the ON position. Do not start the engine.
Use the electronic service tool to check for an active 1075-6 diagnostic code.
Wait for at least 2 minutes for the EFLP to deactivate. Check for an active 1075-5 diagnostic code.
Turn the keyswitch to the OFF position.
Remove the jumper. Leave the connector for the EFLP relay disconnected.Expected Result:Results:
A 1075-6 diagnostic code was active with the jumper installed. - There are no faults in the wiring for the EFLP relay.Repair: Perform the following repair:
Install a replacement relay.
Reconnect the connector for the EFLP relay.
Turn the keyswitch to the ON position. Do not start the engine. Check for active diagnostic codes.
Wait for at least 2 minutes for the EFLP to deactivate. Check for active diagnostic codes.
Confirm that the fault has been eliminated.STOP
A 1075-5 diagnostic code is still active with the jumper installed - Proceed to Test Step 4.Test Step 4. Measure the Voltage at the Relay Connector
Turn the keyswitch to the ON position. Do not start the engine.
Use a voltmeter to measure the voltage between Test Point 1 on the harness connector for the Electric Fuel Lift Pump (EFLP) relay and a suitable ground. Refer to Illustration 1.Expected Result:The measured voltage should be a constant 22.0 to 27.0 VDC.Results:
OK - The voltage is within the expected range. The wiring to the input of the


Parts grommet JOHNSON:

0510761
 
0510761 GROMMET
55ES69A, 60ES70B, 60ES71C, 65ES72S, 65ES73R, TR-10R
0313785
 
0313785 GROMMET
55ES69A, 60ES70B, 60ES71C, 65ES72S, 65ES73R, 70EL76D, 70EL77S, 70EL78C, 70EL79R, 70ES74M, 70ES75B, 75ELR76D, 75ELR77S, 75ELR78C, 75ELR79R, 75ESLR75B, J60ELCDS, J60ELCUC, J70ELCIH, J70ELCNB, J70ELCOS, J70ELCRD, J70ELCSA, J70ELCTE, J75ECCA, J75ECDC, J7
0305145
GROMMET
0305145 GROMMET
100ESL71A, 100ESL72R, 100ML79S, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL7
0314008
GROMMET, Water tube
0314008 GROMMET, Water tube
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 55ES69A, 60ES70B, 60ES71C, 65ES72S, 65ES73R, 70EL76D, 70EL77S, 70EL7
0316354
GROMMET,Cover
0316354 GROMMET,Cover
100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 15E74G, 15E
0325958
 
0325958 GROMMET,Throttle cable
J20CRCOS, J25ECIB, J25ECNE, J25ECOC, J25ECRS, J25ECTD, J25RCSA, J30ECRR, J35ECND, J35ECRR, J35ECSM, J35ECTS, J40ECRM, J50BECRM, J55RSLN, J55RWLCOS, J55RWLCRD, J5RCIC, J5RCSS, J5RHCNR, J5RHCTA, J60ELCRE, J65RWLCRS, J6RCRM, J8RCIC, J8RCNR, J8RCRM, J8RC
0326136
 
0326136 GROMMET,Bracket to manifold
AM55RSLD, BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ50BEEDS, BJ50EEER, BJ50ELSIF, BJ50ELSSA, BJ50ESECC, BJ50RLEUC, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J25JRTSSS, J30JREEM, J30JRSIE, J30JRSSB, J35AELCDE, J35AELCUD, J40AEL
0326130
 
0326130 GROMMET,Screw
AM55RSLD, BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ50BEEDS, BJ50EEER, BJ50ELSIF, BJ50ELSSA, BJ50ESECC, BJ50RLEUC, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J105WELEEN, J105WELSIF, J105WELSSC, J105WRLEES, J105WRLSIF, J105WRLSS
Back to top