0123278 HANDLE, Side mount JOHNSON
J120TLAEM, J120TLASB, J120TLCCA, J140CXCCS, J140CXCEC, J140CXESR, J150CXCCA, J150CXCEM, J150CXESB, J175STLACM, J175STLCEB, J175STLESE, J185ESXESS, J185ESXW, J200CXCCR, J200CXCEA, J200CXESM, J225CXCCE, J225CXCED, J225CXESS, J275CXCCA, J300CXCCA, J300C
HANDLE
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
J120TLASB, J120TLESB, J120TXESB, VJ120TLASB, VJ120TLESB, VJ120TXESB 1990
J120TLCCA, J120TXCCA 1988
J140CXCCS, J140TLCCM, J140TXCCM 1988
J140CXCEC, J140TLAEB, J140TLCEB, J140TXCEB 1989
J140CXESR, J140TLASE, J140TLESE, J140TXESE, VJ140TLASE, VJ140TLESE, VJ140TXESE 1990
J150CXCCA, J150TLCCA, J150TXCCA 1988
J150CXCEM, J150TLAEM, J150TLCEM, J150TXCEM, TJ150TXCEM 1989
J150CXESB, J150TLASB, J150TLESB, J150TXESB, VJ150TLESB, VJ150TXESB 1990
J175STLACM, J175STLCCM, J175TLCCM, J175TXCCM 1988
J175STLCEB, J175TXCEB 1989
J175STLESE, J175TXESE, VJ175SLESE, VJ175TXESE 1990
J185ESXESS 1990
J185ESXW 1989
J200CXCCR, J200STLACM, J200STLCCM, J200TXCCR 1988
J200CXCEA, J200STLCEB, J200TXCEA, TJ200TXCEA 1989
J200CXESM, J200STLESE, J200TXESM, VJ200SLESE, VJ200TXESM 1990
J225CXCCE, J225PLCCE, J225PXCCE, J225TLCCE, J225TXCCE 1988
J225CXCED, J225PLAED, J225PLCED, J225PXCED, J225TLAED, J225TLCED, J225TXCED 1989
J225CXESS, J225PLASS, J225PLESS, J225PXESS, J225TLASS, J225TLESS, J225TXESS, VJ225PLESS, VJ225PXESS, VJ225TLASS, VJ225TLESS, VJ225TXESS 1990
J275CXCCA, J275PLCCA, J275PXCCA 1988
J300CXCCA, J300PLCCA, J300PXCCA 1988
J300CXCEM, J300PLCEM, J300PXCEM 1989
J300CXESB, J300PLESB, J300PXESB 1990
Information:
Table 1
Diagnostic Trouble Codes for the Ground Level Shutdown Switch
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
4215-3 267-3 Remote Shutdown Input voltage above normal The Electronic Control Module (ECM) detects the following condition:
Both contacts from the ground level shutdown switch are in the open state.
4215-4 267-4 Remote Shutdown Input voltage below normal The Electronic Control Module (ECM) detects the following conditions:
Both contacts from the ground level shutdown switch are in the closed state. The ground level shutdown switch allows the engine to be stopped from ground level. When the switch is moved to the STOP position, the engine shuts down. The ECM remains powered. The ground level shutdown switch must be in the RUN position and the power to the ECM must be cycled before the engine can restart.
Illustration 1 g06104321
Schematic for the ground level shutdown switch
Illustration 2 g03812171
Ground level shutdown switch connector
(1) Ground level shutdown switch (N/C)
(2) Switch ground
(3) Ground level shutdown switch (N/O)Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the terminal connections on the P1 ECM connector and the switch connector.
Refer to Troubleshooting, "Electrical Connector - Inspect".
B. Perform a 45 N (10 lb) pull test on each ground level shutdown wire in the ECM connector and the switch connector.
C. Check the screw for the ECM connector for the correct torque of 5 N m (44 lb in).
D. Check the harness for corrosion, abrasion, and pinch points from the solenoids to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Place the ground level shutdown switch in the RUN position.
D. Turn the keyswitch to the ON position. Wait at least 20 seconds for activation of the diagnostic codes.
E. Verify if any of the diagnostic codes that are listed in Table 1 are active.
F. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: No diagnostic codes are active or logged.
Repair: The switch is operating normally. There may be an intermittent fault in the wiring harness or in a connector. Check the wiring harness and the connectors for an intermittent electrical fault. Refer to Troubleshooting, "Electrical Connector - Inspect".
Result: A 4215-3 (267-3) diagnostic is active.
Proceed to Test Step 3.
Result: A 4215-4 (267-4) diagnostic is active.
Proceed to Test Step 5.
3. Create a Short Circuit at the Shutdown Switch Connector
A. Turn the keyswitch to the OFF position.
B. Fabricate a jumper wire. Install the jumper wire between terminal 1 and terminal 2 on the harness connector for the shutdown switch.
C. Turn the keyswitch to the ON position.
D. Use the electronic service tool to check for an active 4215-3 (267-3) diagnostic code.
E. Turn the keyswitch to the OFF position. Remove the jumper wire.
Diagnostic code
Result: The 4215-3 (267-3) diagnostic code is no longer active with the jumper installed.
Repair: Install a replacement ground level shutdown switch.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The 4215-3 (267-3) diagnostic code is still active with the jumper installed.
Proceed to Test Step 4.
4. Check the (N/C) Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch. Disconnect the P1 connector from the ECM.
C. Measure the resistance between terminal 1 on the shutdown switch harness connector and P1:41.
Less than 5 Ohms
Result: The measured resistance is greater than 5 Ohms. The fault is in the wiring between the ground level shutdown switch and the P1 ECM connector.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The measured resistance is less than 5 Ohms.
Contact the Dealer Solutions Network (DSN).
5. Create an Open Circuit at the Shutdown Switch Harness Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch.
C. Turn the keyswitch to the ON position.
D. Use the electronic service tool to check for an active 4215-3 (267-3) diagnostic code.
Diagnostic code
Result: A 4215-3 (267-3) diagnostic code is active with the switch disconnected.
Repair: Install a replacement ground level shutdown switch.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: There are no active 4215 (267) diagnostic codes with the switch disconnected.
Proceed to Test Step 6.
6. Check the (N/O) Wiring for a Short Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch. Disconnect the P1 connector from the ECM.
C. Check the resistance between P1:40 and all other terminals on the P1 connector.
Greater than 1.0 k Ohm
Result: At least one of the resistance measurements is less than 1.0 k Ohm. There is a short in the wiring between the ground level shutdown switch and the P1 connector.
Repair: Repair the faulty wiring or replace the faulty wiring.
Result: All resistance measurements are greater than 1.0 k Ohm.
Contact the Dealer Solutions Network (DSN).
Parts handle JOHNSON:
0327164
0327164 HANDLE, Remote control
CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM, J100STLCCA, J100STLCEM, J100STLESB, J100WMLCDR, J100WMLCOC, J100WMLCRS, J100WTLCUA, J100WTLESM, J100WTLZ, J10EESC, J110MLCCA, J110MLCDC, J110MLCEM, J110MLCUR, J115MLCNB, J115MLCOS, J115MLCRD,