0123238 HOUSING,Upper JOHNSON
D25RWA, J10ELCRA, J10ELCTC, J125ESXESS, J125ESXW, J15ECRM, J15ECTR, J25RWCUR, J25RWEIM, J25RWESA, J25RWK, J30ECDM, J30ECOA, J30ECRR, J35ECRR, J35ECTS, J35RCDM, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, J45RCCDS, J45RCE, J45RCEIA, J45RCESR, J55RSLN, J55R
HOUSING
Price: query
Rating:
Compatible models:
D25RWA
J10ELCRA
J10ELCTC
J125ESXESS
J125ESXW
J15ECRM
J15ECTR
J25RWCUR
J25RWEIM
J25RWESA
J25RWK
J30ECDM
J30ECOA
J30ECRR
J35ECRR
J35ECTS
J35RCDM
J40RSLR
J40RWCDB
J40RWCOM
J40RWCRA
J45RCCDS
J45RCE
J45RCEIA
J45RCESR
J55RSLN
J55RWLCDC
J55RWLCOS
J55RWLCRD
J55RWLE
J55RWLEIA
J55RWLESR
J65WMLEIB
J65WMLESM
J65WMLZ
N65WMLM
R55RWLR
S45RCLR
JOHNSON
BRP JOHNSON entire parts catalog list:
- FUEL TANK » 0123238
J10ELCTC, J10RCTC, J10RCTR, J10RLCTC, J10RLCTR, J10SELCTC 1983
J125ESXESS 1990
J125ESXW 1989
J15ECRM, J15ELCRM, J15RCRM, J15RLCRM 1984
J15ECTR, J15ELCTR, J15RCTA, J15RCTR, J15RLCTA, J15RLCTR 1983
J25RWCUR, J25RWLCUR 1987
J25RWEIM, J25RWLEIM 1991
J25RWESA, J25RWLESA 1990
J25RWK, J25RWLK 1989
J30ECDM, J30ELCDM, J30RCDM, J30RLCDM, J30TECDM, J30TELCDM 1986
J30ECOA, J30ELCOA, J30RCOA, J30RLCOA, J30TECOA, J30TELCOA 1985
J30ECRR, J30ELCRR 1984
J35ECRR, J35ELCRR, J35RCRR, J35RLCRR, J35TELCRR 1984
J35ECTS, J35ELCTS, J35RCTS, J35RLCTS, J35TELCTS 1983
J35RCDM, J35RLCDM 1986
J40RSLR, J40RSR, J40RWCTR, J40RWLCTR 1983
J40RWCDB, J40RWLCDB 1986
J40RWCOM, J40RWLCOM 1985
J40RWCRA, J40RWLCRA 1984
J45RCCDS, J45RCLCDS 1986
J45RCE, J45RCLE, J45WMLE 1989
J45RCEIA, J45RCLEIA, J45WMLEIA 1991
J45RCESR, J45RCLESR, J45WMLESR 1990
J55RSLN, J55RSLN-2, J55RSN, J55RSN-2, J55RSYN, J55RSYN-2 1983
J55RWLCDC 1986
J55RWLCOS 1985
J55RWLCRD 1984
J55RWLE 1989
J55RWLEIA 1991
J55RWLESR 1990
J65WMLEIB 1991
J65WMLESM 1990
J65WMLZ 1989
N65WMLM 1988
R55RWLR 1988
S45RCLR, S45RCR 1988
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
1491-3 Right Turbo Turbine Inlet Temperature Sensor voltage above normal The ECM detects a duty cycle that is greater than 96 percent for ten seconds. The code is logged.
If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
1491-4 Right Turbo Turbine Inlet Temperature Sensor voltage below normal The ECM detects a duty cycle that is less than 4 percent for ten seconds.
1491-8 Right Turbo Turbine Inlet Temperature Sensor abnormal frequency, pulse width, or period The ECM detects a sensor frequency that is greater than 600 Hz or less than 400 Hz.
1492-3 Left Turbo Turbine Inlet Temperature Sensor voltage above normal The ECM detects a duty cycle that is greater than 96 percent for ten seconds. The code is logged.
If the signal from the other exhaust temperature sensor is OK, the signal from that sensor is used. If the signal from the other exhaust temperature sensor is not OK, a default value of 0 °C (32 °F) is used.
1492-4 Left Turbo Turbine Inlet Temperature Sensor voltage below normal The ECM detects a duty cycle that is less than 4 percent for ten seconds.
1492-8 Left Turbo Turbine Inlet Temperature Sensor abnormal frequency, pulse width, or period The ECM detects a sensor frequency that is greater than 600 Hz or less than 400 Hz. System OperationUse this procedure to troubleshoot any suspect problems with the sensor for the left turbocharger turbine inlet temperature or the right turbocharger turbine inlet temperature.The Pulse Width Modulated Sensor (PWM) provides a signal to the engine's ECM. The PWM signal is used to represent certain engine operating conditions. The sensors receive 8.0 0.4 VDC from a regulated power supply.The ECM performs an automatic calibration of these sensors whenever the ECM is powered and the engine has been off for at least five seconds.The ECM provides short circuit protection for the internal power supply. A short circuit to the battery will not damage the internal power supply.The following components can cause problems with the power supply:
Electrical connector or wiring
Sensor
ECMThe most likely cause of a problem is a problem with an electrical connector or wiring. The least likely cause is a problem with the ECM.
Illustration 1 g01534113
Schematic of the PWM sensors for the sensor signal circuit
Illustration 2 g01534075
Location of the connectors that are for the PWM sensor circuit (top side engine view)
(1) Sensor for the right turbocharger turbine inlet temperature
(2) Sensor for the left turbocharger turbine inlet temperature
(3) Right rail connector
(4) Left rail connector
(5) J1/P1 ECM connector
(6) J2/P2 ECM connector
Illustration 3 g01279964
Terminal locations at the P1 ECM connector that are for the sensors for the turbocharger turbine inlet temperature
(P1-5) Digital return
(P1-18) Digital return
Illustration 4 g01279871
Terminal locations at the P2 ECM connector that are for the sensors for the turbocharger turbine inlet temperature
(P2-29) Digital supply
(P2-65) Left turbocharger turbine inlet temperature
(P2-73) Right turbocharger turbine inlet temperature
(P2-92) Digital return
Illustration 5 g01826777
Terminal locations at the left rail connector that are for the sensors for the turbocharger turbine inlet temperature
(Terminal 49) Left turbocharger turbine inlet temperature
(Terminal 63) Digital supply
(Terminal 69) Digital return
Illustration 6 g01534394
Terminal locations at the right rail connector that are for the sensors for the turbocharger turbine inlet temperature
(Terminal 49) Right turbocharger turbine inlet temperature
(Terminal 63) Digital supply
(Terminal 69) Digital return
Illustration 7 g01240891
Sensor connector
(Terminal 1) Sensor supply
(Terminal 2) Sensor return
(Terminal 3) Signal Test Step 1. Check for an "Active" Diagnostic Code
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the diagnostic codes on Cat ET. Check and record any diagnostic codes. Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Determine if a diagnostic code has occurred several times. Note: A diagnostic code that is logged several times is an indication of an intermittent problem. Most intermittent problems are the result of a bad connection between a socket and a pin in a connector or a bad connection between a wire and a terminal.
Look for one or more of the following diagnostic codes that are active or logged:
1491-03
1491-04
1491-08
1492-03
1492-04
1492-08Expected Result:No diagnostic code is active for the exhaust temperature sensors.Results:
OK - No diagnostic codes are active.Repair: There may be an intermittent problem in the harness or in a connector. If an intermittent
Parts housing JOHNSON:
0581778
0581778 HOUSING,Rectifier and lead assembly
10E77A, 10E78M, 10EL79B, 15E77M, 15E78B, 15E79E, 25E77S, 25E78C, 25E79R, 35E77C, 35E78R, 35E79A, 50R79C, 55E78S, 55E79C, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30EECS, BJ30EEDE, BJ30EEEC, BJ30
0323109
0323109 HOUSING,Lower mount,stbd.
25E77S, 25E78C, 25E79R, 35E77C, 35E78R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEU
0323108
0323108 HOUSING,Lower mount,port
25E77S, 25E78C, 25E79R, 35E77C, 35E78R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEU
0390613
0330560
0330560 HOUSING, Impeller
D25RWA, HJ25FPO, HJ25FPV, J25RWCDC, J25RWCOS, J25RWCUR, J25RWEIM, J25RWENB, J25RWEOS, J25RWERD, J25RWESA, J25RWETE, J25RWK, J28ELCDS, J28ELCDS, J28ESLCCR, J28ESLCCR, J28ESLCEA, J28ESLCEA, J28ESLCUC, J28ESLCUC, J28ESLEDR, J28ESLEDR, J28ESLEIB, J28ESLE
0397221
0397221 HOUSING & COVER ASSY.
CJ275TLCDC, CJ300TLCDC, D100WTLM, J100STLCCA, J100WMLCDR, J100WTLCUA, J110MLCCA, J110MLCDC, J110MLCUR, J120TLCCA, J120TLCDC, J120TLCUR, J140CXCCS, J140TLCDC, J140TLCUA, J150CXCCA, J150GTLCUR, J150STLACA, J150STLCDC, J150TLCDC, J150TLCUR, J155WTLCDR,
0397186
0432319
0432319 HOUSING AY
J40ECEC, J45RCE, J45RCESR, J48ESLCER, J48ESLCER, J50BECEC, J50TELCEC, J55RWLE, J55RWLESR