5034602 JOHNSON HOUSING, SHIFT ROD GUIDE


5034602 HOUSING, SHIFT ROD GUIDE JOHNSON BJ115L4SDA, BJ115L4SRC, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ90PL4SDA, BJ90PL4SRC, J115PL4SOR, J140CX4SOR, J140PL4SOR, J140PX4SOR, J90PL4SOR HOUSING
5034602 HOUSING, SHIFT ROD GUIDE JOHNSON
Rating:
68

Buy HOUSING, SHIFT ROD GUIDE 5034602 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 2
 

BRP JOHNSON entire parts catalog list:

BJ115L4SDA, BJ115PX4SDA, J115PL4SDA, J115PX4SDA 2006
BJ115L4SRC, BJ115X4SRC, J115PL4SRC, J115PX4SRC 2004
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140PL4SOR 2005
J140PX4SOR 2005
J90PL4SOR, J90PX4SOR 2005

Information:


Illustration 1 g01045468
Schematic diagram of the electrical power supplyThe engine is not equipped with a remote control panel.
Illustration 2 g01045535
Schematic diagram of the electrical power supplyThe engine is equipped with a remote control panel that only includes a status control module.
Illustration 3 g01045536
Schematic diagram of the electrical power supplyThe engine is equipped with a remote control panel that includes a status control module and air/fuel ratio control.
Illustration 4 g01045538
Schematic diagram of the electrical power supplyThe engine is configured for Canadian Standards Association (CSA). The engine is equipped with an optional remote control panel with air/fuel ratio control.Test Step 1. Inspect the Electrical Connectors
Set the engine control to the OFF/RESET mode. Remove the electrical power from the engine.Note: For the following steps, refer to Troubleshooting, "Inspecting Electrical Connectors".
Thoroughly inspect each of the following connectors:
EIS connectors on the control module
ECM J2/P2 connectors
Connectors for the 24 VDC power supply
Connectors for the engine control
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the electrical power supply.
Check the harness and wiring for abrasion and for pinch points from the power supply to each module.Expected Result:The connectors, pins, and sockets are connected properly. The connectors and the wiring do not have corrosion, abrasion, or pinch points.Results:
OK - The components are in good condition with proper connections. Proceed to Test Step 2.
Not OK - The components are not in good condition and/or at least one connection is improper.Repair: Perform the necessary repairs and/or replace parts, if necessary. Ensure that all of the seals are properly installed. Make sure that the connectors are properly fastened. Verify that the repair has eliminated the problem.STOPTest Step 2. Check the Circuit Breakers for Continuity
Measure the resistance across each of the circuit breakers.Expected Result:The resistance is less than 2 Ohms.Results:
OK - The resistance is less than 2 Ohms. The circuit breakers do not have a short circuit. Proceed to Test Step 3.
Not OK - The resistance of a circuit breaker is greater less than 2 Ohms. A circuit breaker is faulty.Repair: Repair the circuit breaker or replace the circuit breaker. Verify that the original problem is resolved.STOPTest Step 3. Check for a Short Circuit
Disconnect the following connectors:
EIS connectors
P1 and P2 connectors for the ECM
P4 connector for the PWM converter
The "+" and "−" connections for the status control module
Disconnect the electronic service tool.
Verify that the engine control is in the OFF/RESET mode.
Measure the resistance between the following terminal strip connections:
Table 1
Resistance Measurements for the Power Supply    
Terminal Strip Connection    Terminal Strip Connection    
5 (−Battery)     1 (+Battery)    
2 (+Battery)
102-107 (Keyswitch)
285 (+Battery for the oxygen buffer)
Measure the resistance between terminal strip connection 5 and the engine block surface.Expected Result:Each check of the resistance is greater than 5 Ohms.Results:
OK - Each check of the resistance is greater than 5 Ohms. The wiring for the power supply does not have a short circuit. Proceed to Test Step 4.
Not OK - At least one check of the resistance is less than 5 Ohms.Repair: Repair the wiring, when possible. Replace parts, if necessary. Verify that the original problem is resolved.STOPTest Step 4. Check the EIS Control Module for a Short Circuit
Connect the EIS connectors.
Measure the resistance between terminal strip connections 5 and 103.Expected Result:The resistance is greater than 5 Ohms.Results:
OK - The resistance is greater than 5 Ohms. The EIS control module does not have a short circuit. If the engine is equipped with an ECM, proceed to Test Step 5. If the engine is equipped with a status control module, proceed to Test Step 7.
Not OK - The resistance is less than 5 Ohms. The EIS control module has a short circuit.Repair: Replace the EIS control module. Refer to Troubleshooting, "Replacing the EIS Control Module".STOP


Parts housing JOHNSON:

5033847
 
5033847 HOUSING, SHIFT CAM
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J90PL4SOR
5033565
 
5033565 HOUSING, PROP SFT BRG
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J90PL4SOR
5033846
 
5033846 HOUSING
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J90PL4SOR
5034098
 
5034098 HOUSING, BEARING
BJ140CX4SRS, J140CX4STS
5034099
 
5034099 HOUSING, REV GEAR BEARING
BJ140CX4DR, BJ140CX4SRS, J140CX4SOR, J140CX4STS
5033946
 
5033946 HOUSING, PROP SFT BRG
BJ140L4SDR, BJ140PL4SRS, J140PL4SOR, J140PL4STS, J140PX4SOR
5034635
 
5034635 HOUSING - 20 in.
BJ115L4SRC, BJ140CX4SRS, BJ140PL4SRS, BJ90PL4SRC, J115PL4SOR, J140CX4SOR, J140PL4SOR, J140PX4SOR, J90PL4SOR
5034636
 
5034636 HOUSING - 25 in.
BJ115L4SRC, BJ140CX4SRS, BJ140PL4SRS, BJ90PL4SRC
Back to top