5030821 JOHNSON LEAD ASSY., Mount brkt. to hsg.


5030821 LEAD ASSY., Mount brkt. to hsg. JOHNSON BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4S LEAD
5030821 LEAD ASSY., Mount brkt. to hsg. JOHNSON
Rating:
38

Buy LEAD ASSY., Mount brkt. to hsg. 5030821 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$45.52
 

28-11-2020
4.40924524[1.80] Pounds
-: -
Connected Essentials 5030821 Tailored Heavy Duty Custom Fit Car Mats, Black with Grey Trim, Premium
Complete set of 4 tailored custom fit car mats - designed and manufactured specifically for Vauxhall Insignia (2008-2013) || Supplied with clips (as applicable) for security || Driver's mat with heel pad of the same thickness as the mat itself - to reduce wear and protect footwear || Manufactured from 650gram automotive quality carpet - for strength and durability || Images shown are for example only. Mats supplied will be the specific fit for your make & model - see actual template (in images) for this vehicle model.
Number on catalog scheme: 2
 

BRP JOHNSON entire parts catalog list:

BJ115L4SDA, BJ115PX4SDA, J115PL4SDA, J115PX4SDA 2006
BJ115L4SRC, BJ115X4SRC, J115PL4SRC, J115PX4SRC 2004
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ40PL4SDR, J40PL4SDE 2006
BJ40PL4SOC, J40PL4SOB 2005
BJ40PL4SRS, J40PL4SRM 2004
BJ50PL4SDR, J50PL4SDE 2006
BJ50PL4SOC, J50PL4SOB 2005
BJ50PL4SRS, J50PL4SRM 2004
BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J10BL4SUM, J10EL4SUM 2007
J10EL4SDA 2006
J10EL4SOR, J10R4SOA, J10RL4SOA, J10TBL4SOB, J10TE4SOA, J10TEL4SOA 2005
J10EL4SRC 2004
J10R4SDM 2006
J10R4SNF, J10RL4SNF, J10TE4SNF, J10TEL4SNF 2002
J10R4SR, J10RL4SR, J10TBL4SR, J10TE4SR, J10TEL4SR 2004
J10R4STC, J10RBL4STS, J10REL4STS, J10RL4STC, J10TBL4STC, J10TE4STC, J10TEL4STC 2003
J10R4SUB, J10RL4SUB 2007
J10RL4SDM 2006
J10TBL4SDE 2006
J10TBL4SUD, J10TE4SUB, J10TEL4SUB 2007
J10TE4SDM, J10TEL4SDM 2006
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140CX4STS 2003
J140PL4SOR 2005
J140PL4STS, J140PX4STS 2003
J140PX4SOR 2005
J15EL4SDC 2006
J15EL4SOS, J15R4SOA, J15RL4SOA, J15TE4SOA, J15TEL4SOA 2005
J15EL4SUR 2007
J15R4SDM 2006
J15R4SNF, J15RL4SNF, J15TE4SNF, J15TEL4SNF 2002
J15R4SR, J15TE4SR, J15TEL4SR 2004
J15R4STC, J15RL4STC, J15TE4STC, J15TEL4STC 2003
J15R4SUB, J15RL4SUB 2007
J15RL4SDM 2006
J15RL4SR 2004
J15TE4SDM, J15TEL4SDM 2006
J15TE4SUB, J15TEL4SUB 2007
J25PL4SOC, J25TEL4SOC 2005
J25PL4SRS 2004
J30PL4SDR 2006
J30PL4SOC, J30TEL4SOC 2005
J30PL4SRS 2004
J30PL4SUA 2007
J30TEL4SDR 2006
J30TEL4SUA 2007
J40PL4SNF 2002
J40PL4STC 2003
J50PL4SNF 2002
J50PL4STC 2003
J60PL4SNF 2002
J70FLTLECS 1998
J70PL4SNF 2002
J90PL4SOR, J90PX4SOR 2005

Information:


Illustration 1 g00735010
SchematicTest Step 1. Check for Connector Damage
Turn the keyswitch to the OFF/RESET position.
Check the J1/P1 ECM connector, J3/P3 machine connector, and the associated wiring for the following problems: damage, corrosion, abrasion and incorrect attachment. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:The connectors and wiring are free of the following problems: damage, corrosion, abrasion and incorrect attachment.Results:
OK - Proceed to test step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem. Stop.Test Step 2. Check the Switch Status
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position.
Operate the ground level shutdown switch.
Observe the status for "Shutdown Switch" on Cat ET.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switch reads "ON" with the switch in the STOP position. The status reads "OFF" with the switch in the RUN position.Results:
OK - The switch is operating normally.Repair: Refer to Troubleshooting, "Electrical Connectors - Inspect" if the problem is intermittent. Stop.
Not OK - Proceed to Test Step 3.Test Step 3. Short the Wires at the SwitchLabel the switch wiring before removing the wires.
Disconnect all of the wires from the ground level shutdown switch.
Use a suitable piece of wire to short F716-WH and 998-BR together.
Turn the keyswitch to the ON position.
Observe the status for "Shutdown Switch" on Cat ET.
Remove the wire short between F716-WH and 998-BR.
Use a suitable piece of wire to short F715-PU and 998-BR together.
Ensure that the keyswitch is in the ON position.
Observe the status for "Shutdown Switch" on Cat ET.
Remove the wire short.Expected Result:The status of the switch reads "OFF" when F716-WH and 998-BR are shorted together. The status for "Shutdown Switch" reads "ON" when F715-PU and 998-BR are shorted together.Results:
OK - The problem is not with the harness and/or the ECM.Repair: Temporarily connect a new switch. Verify that the new switch solves the problem before you permanently install the new switch. Stop.
Not OK - There is a problem in the harness and/or the ECM. Proceed to test step 4.Test Step 4. Check for a Short Circuit in the Wiring Harness
Illustration 2 g00938936
P1 ECM connector
Turn the keyswitch to the OFF/RESET position.
Disconnect the J1/P1 ECM connector and the wires at the ground level shutdown switch.
Measure the resistance between the following wires:
P1:2 (Ground Level Shutdown (NO)) to P1:29 (Digital Return)
P1:8 (Ground Level Shutdown (NC)) to P1:29 (Digital Return)
P1:2 (Ground Level Shutdown (NO)) to P1:8 (Ground Level Shutdown (NC))
P1:8 (Ground Level Shutdown (NC)) to engine ground
P1:2 (Ground Level Shutdown (NO)) to engine groundExpected Result:The resistance is greater than 20,000 Ohms for each measurement.Results:
OK - There are no shorts in the harness. Proceed to test step 5.
Not OK - There is a short circuit in the harness or connectors between the switch and the ECM.Repair: Repair the circuit.Verify that the repair eliminates the problem. Stop.Test Step 5. Check the Resistance Through the Harness
Illustration 3 g00735074
P1 ECM Connector (wire side)
Ensure that the J1/P1 ECM connector is disconnected, and ensure that the wires at the ground level shutdown switch are disconnected.
Short F715-PU and 998-BR together at the ground level shutdown switch.
Measure the resistance between P1:2 (Ground Level Shutdown (NO)) and P1:29 (Digital Return).
Remove the wire short.
Short F716-WH and 998-BR together at the ground level shutdown switch.
Measure the resistance between P1:8 (Ground Level Shutdown (NC)) and P1:29 (Digital Return).
Remove the wire short.Expected Result:The resistance is less than 10 Ohms for each measurement.Results:
OK - The resistance is within acceptable limits. Proceed to test step 6.
Not OK - There is an open or excessive resistance in the harness.Repair: Repair the harness.Verify that the repair eliminates the problem. Stop.Test Step 6. Short the Switch Inputs at the ECM
Illustration 4 g00735074
P1 ECM Connector (wire side)
Turn the keyswitch to the OFF position.
Disconnect the J1/P1 ECM connector.
Use a 121-9587 Wire Removal Tool to remove the following wires from the P1 ECM connector:
P1:2 (Ground Level Shutdown (NO))
P1:8 (Ground Level Shutdown (NC))
P1:29 (Digital Return)
Fabricate a jumper wire out of 18 AWG insulated wire with Deutsch socket terminals on each end.
Insert one end of the jumper wire into P1:8 (Ground Level Shutdown (NC)) on the P1 ECM connector and insert the other end into P1:29 (Digital Return) on the P1 ECM connector.
Reconnect the J1/P1 ECM connector.
Turn the keyswitch to the ON position.Note: Additional diagnostic codes will be generated because P1:29 (Digital Return) will no longer be connected to other sensors and switches. Clear the additional diagnostic codes upon completing this test.
Observe the status for "Shutdown Switch" on Cat ET.
Turn the keyswitch to the OFF/RESET position.
Disconnect the J1/P1 ECM connector and remove the jumper wire from P1:8 (Ground Level Shutdown (NC)). Leave the other end of the jumper wire in P1:29 (Digital Return).
Insert the loose end of the jumper wire into P1:2 (Ground Level Shutdown (NO)) on the P1 ECM connector.
Reconnect the J1/P1 ECM connector.
Turn the keyswitch to the ON position.
Observe the status for "Shutdown Switch" on Cat ET.


Parts lead JOHNSON:

5030801
 
5030801 LEAD ASSY., Spark plug, No. 1
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030804
 
5030804 LEAD ASSY., Spark plug, No. 4
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030803
 
5030803 LEAD ASSY., Spark plug, No. 4
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030802
LEAD ASSY., Spark plug, No. 2
5030802 LEAD ASSY., Spark plug, No. 2
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030822
 
5030822 LEAD ASSY., Swivel brkt. to hsg.
BJ115L4SDA, BJ140CX4DR, BJ140L4SDR, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC, J60PL4SNF, J70
5033157
 
5033157 LEAD (SWIVEL TO MOUNT) (210mm)
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ70PL4SDM, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM,
5033155
 
5033155 LEAD, NEUTRAL LIMIT
J10EL4SRC, J10R4SNF, J10R4SR, J10R4STC, J15R4SNF, J15R4SR, J15R4STC, J15RL4SR
5033156
 
5033156 LEAD, NEUTRAL LIMIT
J10EL4SRC, J10R4SNF, J10R4SR, J10R4STC, J15R4SNF, J15R4SR, J15R4STC, J15RL4SR
Back to top