0311017 LINK, Idle adjustment JOHNSON
115ESL69E, 40ES69R, 40ES70A, 55ES69A, 85ESL69E, RK-30A, TR-10R, V4A-20A
LINK
Price: query
Rating:
BRP JOHNSON entire parts catalog list:
- REMOTE CONTROL GROUP ELECTRIC SHIFT » 0311017
40ES70A, 40ESL70A 1970
55ES69A, 55ES69C, 55ESL69A, 55ESL69C 1969
85ESL69E, 85ESL69M, 85ESL69S 1969
RK-30A, RK-30C, RK-30D, RKL-30A, RKL-30C, RKL-30D 1968
TR-10R, TR-10S, TRL-10R, TRL-10S 1968
V4A-20A, V4AL-20A 1968
Information:
Table 1
Diagnostic Trouble Codes
J1939 Codes CDL Code Code Description
(code descriptions may vary) Comments
N/A E265 (1) User Defined Shut down The inputs from the user-defined shutdown switch to the Electronic Control Module (ECM) have changed states. The engine will shut down. The code is logged.
N/A E265 (2) User Defined Shut down The inputs from the user-defined shutdown switch to the Electronic Control Module (ECM) have changed states. The engine will shut down. The code is logged.
N/A E265 (3) User Defined Shut down The inputs from the user-defined shutdown switch to the Electronic Control Module (ECM) have changed states. The engine will shut down. The code is logged.
N/A E268 (3) Unexpected Engine Shutdown The engine has stopped unexpectedly. The engine speed is 0 while the ECM is requesting engine speed.
6588-31 E1466(1) Operator Shutdown With High Exhaust Temperature The Engine was stopped before cooling of the exhaust system could complete. Allow Delayed Engine Shutdown to complete. Probable Causes for a E1466 or 6588-31 Code
DES may not be enabled
Improper operation of engine
Machine is not in safe state for DES
Parking break is not engaged
Transmission is not in neutral
Any occurrence that results in engine shutdown prior to DES completion
Depletion of fuel resulting in engine shutdown
Operator forced engine shutdown
Mechanical failureProbable Causes for a E265 Code
Activated shutdown switch
Circuit for the shutdown switchProbable Causes for a E268 Code
Operator caused the engine to stall
Fuel supply
Mechanical Failure
Table 2
Associated Diagnostic Trouble Codes
E678
4215-31
E1217
Table 3
Troubleshooting Test Steps Values Results
1. Determine the Code
A. Establish communication between Cat® Electronic Technician (ET) and the ECM. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Download the "Warranty Report" from the engine ECM before performing any troubleshooting or clearing diagnostic trouble codes.
C. Determine the event code.
Active Codes
Result: An associated code is active.
Repair: Refer to Troubleshooting, "Event Codes" to troubleshoot the associated diagnostic code.
Troubleshoot the associated code before continuing with this procedure.
Result: A E265 code is active or logged.
Proceed to Test Step 6.
Result: A E268 (3) code is active or logged.
Proceed to Test Step 3.
Result: A E1466 or 6588-31 code is active or logged.
Proceed to Test Step 2.
2. Delayed Engine Shutdown
A. Check if "Delayed Engine Shutdown" is enabled.
B. Connect to Cat® ET, navigate to the "Configuration" tab in the engine ECM. Select the "Delayed Engine Shutdown" tab and check the status of the parameter.
Delayed Engine Shutdown
Result: "Delayed Engine Shutdown" is enabled.
Proceed to Test Step 3.
Result: "Delayed Engine Shutdown" is not enabled.
Repair: Enable "Delayed Engine Shutdown".
Verify that enabling "Delayed Engine Shutdown" eliminated the problem.
3. Proper Engine Operation
A. Interview the operator and determine the events that caused the engine to stall. Refer to Operation and Maintenance Manual (OMM) for proper engine operation.
B. Delayed engine shutdown (DES) may not have completed.
Operator
Result: The operator is operating the engine correctly.
Proceed to Test Step 4.
Result: The operator is not operating the engine correctly.
Repair: Operate the engine correctly.
4. Fuel
A. Check the engine fuel supply.
Fuel
Result: The engine is out of fuel.
Repair: Supply the engine with an adequate fuel supply.
Verify that the repair eliminated the problem.
Result: The engine is not out of fuel.
Proceed to Test Step 5.
5. Mechanical Failure
A. Check for a mechanical failure.
Mechanical Failure
Result: A mechanical failure has occurred.
Repair: Diagnose the problem and then repair the problem.
Verify that the repair eliminated the problem.
6. Activated Shutdown Switch
A. Interview the operator and determine the reason for the emergency stop shutdown.
Switch
Result: The emergency stop shutdown was activated.
Repair: Diagnose the problem and then repair the problem.
Verify that the repair eliminated the problem.
Result: The emergency shutdown was not activated.
Proceed to Test Step 7.
7. Check the Emergency Shutdown Switch Circuit
A. Inspect the stop switches for evidence of damage that has been caused by vibration, moisture, or corrosion.
B. Check the circuit for the shutdown switch. Refer to Troubleshooting, "Shutdown (Ground Level) - Test".
Emergency Shutdown Switch Circuit
Result: The emergency stop shutdown switch is not operating properly or there is a problem with the emergency shutdown circuit.
Repair: Repair or replace the failed component.
Verify that the repair eliminated the problem.
Parts link JOHNSON:
0305994
0305994 LINK,Anchor
100ESL71A, 100ESL72R, 10E74G, 10E75C, 10E76G, 10E77A, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 15E74G, 15E75C, 15E76A, 15E77M, 200TL76S, 20R69B, 20R70
0300364
0300364 LINK,Safety chain
10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 33E70M, 35E77C, 3
0303957
0303957 LINK,Reverse lock arm
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, RD-30A, RDS-30A, RK-30A, RX-16M
0307879
0307879 LINK, Control lever to breaker
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40ES69R, 40R69R, RD-30A, RDS-30A, RK-30A, RX-16M
0378322
0378322 LINK & HOOK
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40ES69R, 40ES70A, 40R69R, 40R70A, RD-30A, RDS-30A, RK-30A, RX-16M, V4A-20A, V4S-20A, VX-14B
0315021
0315021 LINK, Reverse lock stbd
100ESL71A, 115ESL69E, 115ESL70D, 125ESL71C, 85ESL69E, 85ESL70B, 85ESL71A
0315024
0315024 LINK, Reverse lock port
100ESL71A, 115ESL69E, 115ESL70D, 125ESL71C, 85ESL69E, 85ESL70B, 85ESL71A
0315095
0315095 LINK, Slow speed adjust, port
100ESL71A, 115ESL69E, 115ESL70D, 125ESL71C, 85ESL69E, 85ESL70B, 85ESL71A