0391264 JOHNSON MOTOR AND CABLE ASSY.


0391264 MOTOR AND CABLE ASSY. JOHNSON J115MLCIH, J115MLCNB, J140MLCIH, J140MLCNB, J150TLCIA, J150TLCNM, J175TLCIH, J175TLCNB, J200TLCIH, J200TLCNE, J235TLCIB, J235TLCNE, J70ELCIH, J70ELCNB, J75ECNB, J75ERCIH, J90MLCIH, J90MLCNB MOTOR
0391264 MOTOR AND CABLE ASSY. JOHNSON
Rating:
88

Buy MOTOR AND CABLE ASSY. 0391264 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$225.23

05-02-2025
2.5397[1.14] Pounds
CN: TINGFD
Starter Motor Motorcycle tilt trim starter motor OMC Johnson EVINRUDE 0391264 0393259 0393988 0394176 0395840 Starter Replacement
VPBYSIIJFB Please compare your current part to the product picture to confirm it is the correct replacement starter part for your vehicle model to avoid purchasing errors and other causes. || Steel Gears: The gears inside the starter are typically made of high-strength steel to ensure they can withstand high torque and shocks during cranking while maintaining durability and stability. || Gear transmission: The gear system transmits the rotational force of the motor to the engine for starting. Precise manufacturing of individual gears ensures smooth torque transfer and provides reliable starting capability. || Brush Inspection: Periodically check the condition of the brushes and brush holders. If worn, replace them to ensure the brushes are functioning properly and allowing the delicate parts to perform at their best. || We put customer satisfaction first. If you have any questions or misunderstandings about our products, please contact us before purchasing. We will provide you with accurate answers and satisfactory responses within 24 hours.
$243.95

23-12-2024
0.8818[0.40] pounds
CN: CJL--kuajing
Performance Trim Motor OMC Compatible With 394176 983446 393988 0394176 0391264
JHyfLA Performance: Efficient design Compatible with enhanced motor operation and reliability on the water. || Durability: Constructed from robust materials to withstand harsh marine environments. || Maintenance: Simple to maintain, allowing Compatible with quick checks and easy upkeep Compatible with longevity. || Innovation: Advanced engineering Compatible with improved performance and responsiveness during use. || Value: Cost-effective solution Compatible with restoring motor function without breaking the bank.
$318.09
 

01-09-2024
0.1102[0.05] pounds
CN: GUOJIAN168MALL
GrAles Trim Motor Compatible with OMC, Johnson, Evinrude 394176, 983446, 393988, 0394176, 0391264
GrAles The fast response starter motor starts the engine immediately after the press of a button, reducing waiting time. || Compact design: The compact motor design does not take up much space and contributes to the overall styling of the motorcycle. || Low Noise: The quiet design reduces noise and provides a more enjoyable riding experience. || Low vibration: Reducing vibration improves riding comfort. || Fast cooling: The cooling design prevents the motor from overheating.
Number on catalog scheme: 28
 

BRP JOHNSON entire parts catalog list:

J115MLCIH, J115MLCIM, J115TLCIH, J115TLCIM, J115TXCIH, J115TXCIM 1981
J115MLCNB, J115TLCNB, J115TXCNB 1982
J140MLCIH, J140MLCIM, J140TLCIH, J140TLCIM, J140TXCIH, J140TXCIM 1981
J140MLCNB, J140TLCNB, J140TXCNB 1982
J150TLCIA, J150TLCIH, J150TXCIA, J150TXCIH 1981
J150TLCNM, J150TXCNM 1982
J175TLCIH, J175TLCIM, J175TXCIH, J175TXCIM 1981
J175TLCNB, J175TXCNB 1982
J200TLCIH, J200TXCIB, J200TXCIH 1981
J200TLCNE, J200TXCNE 1982
J235TLCIB, J235TLCIH, J235TXCIB, J235TXCIH 1981
J235TLCNE, J235TXCNE 1982
J70ELCIH, J70ELCIM, J70TLCIM 1981
J70ELCNB, J70TLCNB 1982
J75ECNB, J75ELCNB, J75TLCNB 1982
J75ERCIH, J75ERCIM, J75ERLCIH, J75ERLCIM, J75TELCIM, J75TRLCIH 1981
J90MLCIH, J90MLCIM, J90TLCIH, J90TLCIM, J90TXCIH, J90TXCIM 1981
J90MLCNB, J90TLCNB, J90TXCNB 1982

Information:


Table 1
Diagnostic Codes Table
Code Conditions which Generate this Code System Response
446-5 Air Shutdown Relay : Current Below Normal The Electronic Control Module (ECM) detects an open circuit and/or a short to the +Battery in the solenoid circuit. The code is logged.
446-6 Air Shutoff Relay short The ECM detects a short circuit to ground in the solenoid circuit. The ECM has the ability to stop the engine by shutting off the air supply in an emergency situation. The ECM activates the air shutoff solenoid which activates the air inlet shutoff valve.The first condition occurs when the operator initiates an emergency shutdown. When the shutdown is recognized, fuel is shut off and the air shutoff solenoid is activated. The second condition is for an engine overspeed.The customer can activate the air shutoff solenoid by supplying 24 VDC to terminal 54 of the customer connector.Regardless of the reason for activation, the main power to the ECM must be turned OFF for three seconds in order to reset the engine control.Note: The air shutoff is optional. A programmable parameter needs to be set with Caterpillar Electronic Technician (ET) in order to enable the air shutoff.Note: Ensure that the air shutoffs are manually reset after an emergency stop in order to start the engine again.
Illustration 1 g01382553
Typical schematic
Illustration 2 g01381147
P2 ECM connector
(P2-13) Drive for the air shutoff solenoid
(P2-23) Return for the air shutoff solenoid
Illustration 3 g01381149
Customer connector
(Terminal 54) Air shutoff
Illustration 4 g01234146
Location of ECM connectors
Test Step 1. INSPECT ELECTRICAL CONNECTORS AND WIRING
Turn the main disconnect switch to the OFF position.
Thoroughly inspect the J1/P1 ECM connector and the J2/P2 ECM connector. Inspect all of the connectors that are associated with the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connectors that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and wiring for abrasion and for pinch points from the sensors back to the ECM. Expected Result:All connectors, pins and sockets are completely coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and connectors appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem with the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. CHECK FOR ACTIVE DIAGNOSTIC CODES
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Turn the main disconnect switch to the ON position.
Monitor the active diagnostic code screen on Cat ET. Check the air shutoff system for an active diagnostic code. Note: Wait at least 30 seconds in order for any diagnostic codes to become active.
Activate the override for the air shutoff system. Monitor the active diagnostic code screen on Cat ET. Check the air shutoff system for an active diagnostic code. Note: Wait at least 30 seconds in order for the diagnostic code to become active.
Deactivate the override for the air shutoff system. Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic codes are active.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - A -6 diagnostic code is active at this time. Proceed to Test Step 3.
Not OK - A -5 diagnostic code is active at this time. Proceed to Test Step 4.Test Step 3. CREATE AN OPEN AT THE CONNECTOR FOR THE AIR SHUTOFF SOLENOID
Disconnect the connector for the air shutoff solenoid.
Monitor the active diagnostic code screen on Cat ET. Check for an active diagnostic code for the air shutoff system. Note: Wait at least 30 seconds in order for the diagnostic code to become active.
Activate the override for the air shutoff system. Monitor the active diagnostic code screen on Cat ET. Check the air shutoff system for an active diagnostic code. Note: Wait at least 30 seconds in order for the diagnostic code to become active.Expected Result:A -6 diagnostic code was active when the solenoid was connected to the circuit. A -5 diagnostic code is active when the solenoid is removed from the circuit.Results:
OK - A -6 diagnostic code was active before disconnecting the connector. A -5 diagnostic code became active after disconnecting the connector. The harness and the ECM are


Parts motor JOHNSON:

0323067
 
0323067 MOTOR COVER, Lower
70EL78C, 70EL79R, 75ELR78C, 75ELR79R, J65RWLCRS, J70ELCIH, J70ELCNB, J70ELCRD, J70ELCSA, J70ELCTE, J75ECNB, J75ECRD, J75ECTE, J75ERCIH, J75ERCSA
0389254
 
0389254 MOTOR CABLE ASSY
70EL79R, 75ELR79R, J70ELCIH, J70ELCNB, J70ELCSA, J70ELCTE, J75ECNB, J75ECTE, J75ERCIH, J75ERCSA
0389452
 
0389452 MOTOR CABLE ASSY.
150TL79C, 175TL79R, 200TL79A, 235TL70A, J150STLCTE, J150TLCIA, J150TLCNM, J150TLCSF, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCSA, J175TLCTD, J200TLCIH, J200TLCNE, J200TLCSF, J200TLCTD, J235STLCTS, J235TLCIB, J235TLCNE, J235TLCSM, J235TLCTD
0281590
 
0281590 MOTOR COVER ASSY., 90
J115MLCIH, J140MLCIH, J90MLCIH
0281591
 
0281591 MOTOR COVER ASSY., 90
J115MLCIH, J140MLCIH, J90MLCIH
0390605
 
0390605 MOTOR COVER ASSY., 115
J115MLCIH, J140MLCIH, J90MLCIH
0391596
 
0391596 MOTOR COVER ASSEMBLY
J70ELCNB, J75ECNB
0281737
 
0281737 MOTOR COVER ASSY., 90
J115MLCNB, J140MLCNB, J90MLCNB
Back to top