0330047 MOUNT BRACKET JOHNSON
CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, J250CXARC, J250CXATF, J250CXEIE, J250CXEND, J250CXEOR, J275CLCUR, J275CXCCA, J300CLCUR, J300CXCCA, J300CXCEM, J300CXEIE, J300CXEND, J300CXEOR, J300CXERC, J300CXESB, J300CXETF
MOUNT
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- MIDSECTION » 0330047
CJ300TLCDC, CJ300TXCDC, J300TLCDC, J300TXCDC 1986
CJ300TLCOS, CJ300TXCOS, J300TLCOS, J300TXCOS 1985
J250CXARC, J250CXERC, J250CZERC, J250TXARC, J250TXERC, J250TZERC 1994
J250CXATF, J250CXATS, J250CXETF, J250CXETS, J250CZATF, J250CZATS, J250CZETF, J250CZETS, J250TXATF, J250TXATS, J250TXETF, J250TXETS, J250TZATF, J250TZATS, J250TZETF, J250TZETS 1993
J250CXEIE, J250TXEIE 1991
J250CXEND, J250CZEND, J250TXEND, J250TZEND 1992
J250CXEOR, J250CZEOR, J250TXEOR, J250TZEOR 1995
J275CLCUR, J275CXCUR, J275PLCUR, J275PXCUR 1987
J275CXCCA, J275PLCCA, J275PXCCA 1988
J300CLCUR, J300CXCUR, J300PLCUR, J300PXCUR 1987
J300CXCCA, J300PLCCA, J300PXCCA 1988
J300CXCEM, J300PLCEM, J300PXCEM 1989
J300CXEIE, J300PLEIE, J300PXEIE 1991
J300CXEND, J300PLEND, J300PXEND 1992
J300CXEOR, J300PLEOR, J300PXEOR 1995
J300CXERC, J300PLERC, J300PXERC 1994
J300CXESB, J300PLESB, J300PXESB 1990
J300CXETF, J300CXETS, J300PLETF, J300PLETS, J300PXETF, J300PXETS 1993
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
677-5
Engine Starter Motor Relay : Current Below Normal 444-5
Starter Motor Relay : Current Below Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
677-6
Engine Starter Motor Relay : Current Above Normal 444-6
Starter Motor Relay : Current Above Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
931-5
Engine Fuel Supply Pump Actuator : Current Below Normal 1627-5
Fuel Pump Relay : Current Below Normal This code indicates that there is a problem with the engine fuel priming pump relay and/or electrical circuit.
931-6
Engine Fuel Supply Pump Actuator : Current Above Normal 1627-6
Fuel Pump Relay : Current Above Normal This code indicates that there is a problem with the engine fuel priming pump relay and/or electrical circuit.
5386-5
Engine Turbocharger Wastegate Actuator #1 Command : Current Below Normal 526-5
Turbo Wastegate Drive : Current Below Normal The circuit driver for the electrohydraulic actuator solenoid is energized. The ECM detects no current from the actuator or a current that is less than the normal level.
The shutdown output is activated. The code is logged. The engine is shut down.
5386-6
Engine Turbocharger Wastegate Actuator #1 Command : Current Above Normal 526-6
Turbo Wastegate Drive : Current Above Normal The circuit driver for the electrohydraulic actuator solenoid is energized. The ECM detects no current from the actuator or a current that is greater than the normal level.
The shutdown output is activated. The code is logged. The engine is shut down.
Table 2
Component Electrical Checkout
Engine Starter Motor Relay Attempt to start the engine. Once the ECM attempts to energize the relay, the code will become active. Refer to the machine-specific schematic for the "Engine Starter Motor Relay" wiring circuit.
Ether Solenoid Use the "Ether Injection Override" in the override parameters section in Cat® Electronic Technician (ET) to activate the ether starting aid solenoid. Review active diagnostic codes to determine what code is present.
Fuel Priming Pump Fuel Priming Command Override Use the "Fuel Priming Command Override" in the override parameters section in Cat ET to activate the engine fuel pump. Review the active diagnostic codes to determine what code is present.
Turbocharger Wastegate Actuator Engine Turbocharger Wastegate Solenoid Status Override: Use the "Engine Turbocharger Wastegate Solenoid Status Override" in the override parameters section in Cat ET to activate the Turbocharger Wastegate Solenoid. To activate the solenoid, turn the override to Off, which turns the air supply to the turbocharger wastegate off. Review active diagnostic codes to determine what code is present.
Table 3
Required Service Tools
Part Number Description
372-5260 Test Lead Tool Group Reference: Refer to the Electrical Schematic for the pin outs of the coils.
Table 4
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat ET to the service tool connector.
Codes
Result: There is an active or logged -5 code.
Proceed to Test Step 2.
Result: There is an active or logged -6 code.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Disconnect the component from the harness.
C. Connect a jumper wire between the terminals of the harness connector for the affected component. The component coil is replaced with a short circuit.
D. Establish communication between Cat ET and the engine ECM. Select the appropriate "Electrical Checkout" from Table 2 above to activate the desired component.
Open Circuit
Result: A -5 code became active during the electrical checkout. The ECM did not detect the jumper wire. There is an open circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -6 code is activated during the electrical checkout. The ECM detected the jumper wire. There is a problem with the component.
Repair: Replace the component.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Disconnect the component from the harness. The component coil is replaced with an open circuit.
B. Establish communication between Cat ET and the engine ECM. Select the appropriate "Electrical Checkout" from Table 2 above to activate the desired component.
Short Circuit
Result: A -6 code became active during the electrical checkout. The ECM did not detect the open circuit. There is a short circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -5 code is activated during the electrical checkout. The ECM detected the open circuit. There is a problem with the component.
Repair: Replace the component.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts mount JOHNSON:
0315057
0315057 MOUNT, Bracket to exhaust cover
100ESL71A, 100ESL72R, 115ESL69E, 115ESL70D, 125ESL71C, 125ESL72R, 150TL78S, 175TL77S, 175TL78C, 200TL76S, 200TL77C, 200TL78R, 235TL78R, 50ES71S, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 55E76E, 55E77D, 65ES72S, 65ES73R, 70EL76D, 70EL77S, 70EL78C, 70ES74M,
0328584
0328584 MOUNT, Lower cover
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC
0912144
0339419
0339419 MOUNT BRACKET