0514695 MOUNTING BRACKET JOHNSON
BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30EECS, BJ30EEDE, BJ30EEEC, BJ30EEUD, BJ30ELSIA, BJ30ELSSR, J25ELSNF, J25ELSOB, J25ELSRM, J25ELSTA, J28ESLEDR, J28ESLEDR, J30ELSNF, J30ELSOD, J30ELSRE, J
MOUNTING
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- MOTOR CABLE ASSEMBLY » 0514695
BJ20SEEUM, BJ20SELEUM 1997
BJ25EECE, BJ25ELECE, J25EECE, J25ELECE 1998
BJ25EEDM, BJ25ELEDM, BJ25EREDC, BJ25ERLEDC, J25EEDM, J25ELEDM 1996
BJ25EEED, BJ25EEEN, BJ25ELEED, BJ25ELEEN, J25EEED, J25EEEN, J25ELEED, J25ELEEN 1999
BJ25EEUB, BJ25ELEUB, J25EEUB, J25ELEUB 1997
BJ25ELSIC, BJ25ESIC, BJ25EVLSIC, BJ25EVSIC, J25ELSIC, J25ESIC, J25EVLSIC, J25EVSIC 2001
BJ25ELSSS, BJ25ESSS, J25ELSSS, J25ESSS 2000
BJ30EECS, BJ30ELECS, J30EECS, J30ELECS 1998
BJ30EEDE, BJ30ELEDE, J30EEDE, J30ELEDE, SJ30EEDE 1996
BJ30EEEC, BJ30EEEN, BJ30ELEEC, BJ30ELEEN, J30EEEC, J30EEEN, J30ELEEC, J30ELEEN 1999
BJ30EEUD, BJ30ELEUD, J30EEUD, J30ELEUD 1997
BJ30ELSIA, BJ30ESIA, BJ30EVLSIA, BJ30EVSIA, J30ELSIA, J30ESIA, J30EVLSIA 2001
BJ30ELSSR, BJ30ESSR, J30ELSSR, J30ESSR 2000
J25ELSNF 2002
J25ELSOB 2005
J25ELSRM 2004
J25ELSTA 2003
J28ESLEDR 1996
J28ESLEDR 1996
J30ELSNF 2002
J30ELSOD 2005
J30ELSRE 2004
J30ELSTB 2003
Information:
Illustration 1 g01107274
Illustration 2 g01107279When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Minimum speed with no load ... 3300 rpmMaximum current with no load ... 80 ampVoltage ... 23.5 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 1.5 0.5 N m (13 4 lb in) (3) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 17.5 2.5 N m (155 22 lb in)Current draw at 24 V and 25 °C (77 °F)Pull-in windings ... 103 AmpHold-in windings ... 19 Amp maximum 6V-5537 Electric Starting Motor Gp and 6V-5207 Electric Starting Motor Gp
Illustration 3 g01107221
Illustration 4 g01107223When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F)Speed ... 7643 1683 rpmCurrent draw ... 67.5 7.5 ampVoltage ... 23 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 8 3 N m (70 27 lb in)Clearance between the pinion and the housing ... 9.1 mm (0.36 inch) 6V-5023 Electric Starting Motor Gp
Illustration 5 g01107286
Illustration 6 g01107308When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 5500 rpm minimumCurrent draw ... 140 amp maximumVoltage ... 24 V (1) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (2) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 30.5 3.5 N m (270 30 lb in) 9X-0332 Solenoid KitCurrent consumption at 25 °C (77 °F) Pull-in windings at 24 V ... 51 ampHold-in windings at 24 V ... 7 amp