5033713 JOHNSON O-RING, OIL PUMP


5033713 O-RING, OIL PUMP JOHNSON BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J90PL4SOR O
5033713 O-RING, OIL PUMP JOHNSON
Rating:
103

Buy O-RING, OIL PUMP 5033713 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

BRP JOHNSON entire parts catalog list:

BJ115L4SDA, BJ115PX4SDA, J115PL4SDA, J115PX4SDA 2006
BJ115L4SRC, BJ115X4SRC, J115PL4SRC, J115PX4SRC 2004
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140CX4STS 2003
J140PL4SOR 2005
J140PL4STS, J140PX4STS 2003
J140PX4SOR 2005
J90PL4SOR, J90PX4SOR 2005

Information:


Illustration 1 g00951847
Each ECM and the ITSM communicate with Cat ET via the Cat data link. The Cat data link consists of two wires that are twisted together. One wire is designated as +. The other wire is designated as -. The signals on the data link wires are a square wave type signal. The signals operate at a very high frequency. The signals cannot be measured with common service tools. Therefore, only continuity measurements can be made on the wires for the Cat data link.The most likely cause of a diagnostic code for the Cat data link are an open circuit or a short circuit. Connector terminals that are not fully seated in the connector body can create an open circuit condition. Be careful not to interchange the + wire and the - wire in a connector. The Cat data link will not operate if the + wire and the - wire are interchanged in a connector.The Cat data link can fail if a module is not receiving power. This can happen if there is a problem with the wiring that provides power to the module.The Cat data link can fail if a module is programmed with the wrong FLASH file, or if a module has not been programmed with a FLASH file. Verify that all modules have been programmed with the proper FLASH file.Harness Code for the Slave ECMThe harness inside the terminal box has a jumper wire (harness code) that connects terminals J3-29 and J3-60. The ECM that is connected to the harness reads the harness code. This allows the ECM to operate as the slave ECM.If the jumper wire is disconnected, the slave ECM will assume the function of a master ECM. Cat ET will not communicate with any of the modules. Cat ET will display "DupliCate Type on data link. Unable to Service".
Illustration 2 g00994089
Schematic diagram of the Cat data linkTest Step 1. Inspect the Electrical Connectors and wiring
Set the engine control to the OFF/RESET mode. Switch the 16 amp circuit breaker OFF.Note: For the following steps, refer to Troubleshooting, "Inspecting Electrical Connectors".
Illustration 3 g00920000
Terminal box for the master ECM (1) Ground strap (2) J1/P1 connectors for the master ECM (3) J23 connector for Cat ET (4) J19 connector (5) 16 amp circuit breaker (6) J5/P5 connectors for the harness to the ITSM (7) J8/P8 connectors for the harness to the slave ECM (8) J9/P9 connectors
Illustration 4 g00920005
Terminal box for the slave ECM (9) J3/P3 connectors for the slave ECM (10) J20/P20 connectors for the harness to the master ECM
Illustration 5 g00920007
ITSM (11) ITSM (12) J18/P18 connectors for the harness to the terminal box for the master ECM
Thoroughly inspect each of the following connectors:
Master ECM J1/P1 connectors
J23, J5/P5, J8/P8, J9/P9 and J19 connectors on the terminal box for the master ECM
J3/P3 connectors for the slave ECM
J20/P20 connectors on the terminal box for the slave ECM
J18/P18 connectors for the ITSM
Check the torque of the Allen head screw for the ECM connectors. The proper torque is 6 1 N m (53 9 lb in).
Illustration 6 g00994115
Harness side of the master ECM P1 connector and the P3 connector for the slave ECM (P1-8) Cat data link + (P1-9) Cat data link −
Illustration 7 g00994117
Harness side of the P3 connector for the slave ECM (P3-8) Cat data link + (P3-9) Cat data link − (P3-29) Harness code (P3-60) harness code
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit for the Cat data link.
Check the harness and wiring for abrasion and for pinch points from the slave ECM to the master ECM.
Check the wiring harness from the P9 connector to the optional remote control panel.Expected Result:The connectors, pins, and sockets are connected properly. The connectors and the wiring do not have corrosion, abrasion, or pinch points.Results:
OK - The components are in good condition with proper connections. Proceed to Test Step 2.
Not OK - The components are not in good condition and/or at least one connection is improper.Repair: Perform the necessary repairs and/or replace parts, if necessary.STOPTest Step 2. Check the Cat Data Link
Verify that the engine control is in the OFF/RESET mode. Verify that the 16 amp circuit breaker is OFF.
Connect Cat ET to the service tool connector. Refer to Troubleshooting, "Electronic Service Tools".
Set the engine control to the STOP mode. Switch the 16 amp circuit breaker ON.
Select the "File/Select ECM" menu on the Cat ET. Verify that all of the modules are displayed on the "ECM Selector" screen.Verify that the following diagnostic codes are not activated.
0590-09 Unable to communiCate with Engine ECM
1636-09 Loss of communiCation with Engine #2 (Slave)
1042-09 Unable to communiCate with ITSMNote: If Cat ET displays "DupliCate Type on data link. Unable to Service", there may be a problem with the harness inside the terminal box for the slave ECM. Set the engine control to the OFF/RESET mode. Switch the 16 amp circuit breaker OFF. Check the continuity between terminals J3-29 and J3-60. Verify that the jumper wire is in good condition. Make repairs, as needed.Expected Result:All of the modules are displayed on the "ECM Selector" screen. There are no active diagnostic codes for the Cat data link.Results:
OK - All of the modules are displayed on the "ECM Selector" screen. There are no active diagnostic codes for the Cat data link. The problem seems to be resolved.Repair: If any of the above codes are logged and the engine is not running properly, refer to Troubleshooting, "Troubleshooting Without a Diagnostic Code".If any of the above codes are logged and the engine is runnin


Parts o JOHNSON:

5030541
 
5030541 O-RING, Cap
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4S
5030542
O-RING
5030542 O-RING
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
5030540
 
5030540 O-RING, Fuel pump
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA,
5030869
O-RING KIT
5030869 O-RING KIT
BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J70FLTLECS
5030871
 
5030871 O-RING KIT, Cap
BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J70FLTLECS
5030867
 
5030867 O-RING, Reservoir
BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J70FLTLECS
5032589
 
5032589 *O RING
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
5033648
 
5033648 *O RING, C/C WTR JKT COVER
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J90PL4SOR
Back to top