Illustration 1 g01023143
Typical circuit with EMCP IITest Step 1. Check for an Open Circuit in the OFF/RESET Position.
If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the customer connection box.
Disconnect the harness connector from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Turn the ECS to the OFF/RESET position.
At the GSC+ harness connector, measure the resistance from contact "39" to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the -Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "39" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the -Battery terminal is greater than 5000 Ohms.Results:
OK - All resistance measurements are correct. Proceed to Test Step 2.
Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete. Stop.Test Step 2. Check for an Open Circuit in the AUTO Position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the -Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "40" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the -Battery terminal is greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to Test Step 3.
Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed. Stop.Test Step 3. Check for an Open Circuit in the MAN/START Position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the -Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "33" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the -Battery terminal is greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to Test Step 4.
Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the -Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed. Stop.Test Step 4. Check for an Open Circuit in the COOLDOWN/STOP Position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the customer connection box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the COOLDOWN/STOP position. Measure the resistance from contact "32" of the GSC+ harness connector to the -Battery terminal of the relay module. Measure the resistance from contacts "33", "39" and "40" to the -Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "32" to the -Battery terminal of the relay module is 5 Ohms or less. The resistance that is measured from contacts "33", "39" and "40" to the -Battery terminal is greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to Test Step 5.
Not OK - The resistance measurements are not correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed.Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring


Parts oil JOHNSON:

0321453
OIL RETAINER
0321453 OIL RETAINER
100ML79S, 115EL77S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, 85
0321466
OIL RETAINER, Driveshaft
0321466 OIL RETAINER, Driveshaft
200TL76S, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, 70EL76D, 70EL77S, 70EL78C, 70EL79R, 75ELR76D, 75ELR77S, 75ELR78C, 75ELR79R, BJ40EEDS, BJ50BEEDS, BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, HJ45RCLEDS, HJ55RSLW, HJ55WMLM, J35AELCDE, J35AELCUD, J40AELCCS, J40E
0387396
 
0387396 OIL LINE ASSY.,Upper
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, 85TXLR77S
0387397
 
0387397 OIL LINE ASSY.,Lower
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, 85TXLR77S, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, C
0387250
0388065
 
0388065 OIL PUMP ASSY.
115ETZ78C, 115TXL77S, 140ML77S, 140ML78C, 150TL78S, 175TL77S, 175TL78C, 200TL77C, 200TL78R, 235TL78R, 85ETLR78C, 85TXLR77S
Back to top