0984141 OIL FILTER ASSY. JOHNSON
BJ200CXEDR, CJ275TLCDC, CJ300TLCDC, J185ESERK, J185ESXENR, J185ESXESS, J185ESXETA, J185ESXW, J200CXARC, J200CXATF, J200CXCCR, J200CXCEA, J200CXEIB, J200CXENE, J200CXEOC, J200CXESM, J200STLCDR, J200STLCUA, J225CLCUB, J225CXARC, J225CXATF, J225CXCCE, J
OIL
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BJ200CXEDR
CJ275TLCDC
CJ300TLCDC
J185ESERK
J185ESXENR
J185ESXESS
J185ESXETA
J185ESXW
J200CXARC
J200CXATF
J200CXCCR
J200CXCEA
J200CXEIB
J200CXENE
J200CXEOC
J200CXESM
J200STLCDR
J200STLCUA
J225CLCUB
J225CXARC
J225CXATF
J225CXCCE
J225CXCED
J225CXEDE
J225CXEIC
J225CXENR
J225CXEOB
J225CXESS
J225PTLCDA
J250CXARC
J250CXATF
J250CXEIE
J250CXEND
J250CXEOR
J275CLCUR
J275CXCCA
J300CLCUR
J300CXCCA
J300CXCEM
J300CXEIE
J300CXEND
J300CXEOR
J300CXERC
J300CXESB
J300CXETF
JOHNSON
BRP JOHNSON entire parts catalog list:
- POWER STEERING GROUP » 0984141
CJ300TLCDC, CJ300TXCDC, J300TLCDC, J300TXCDC 1986
J185ESERK 1994
J185ESXENR 1992
J185ESXESS 1990
J185ESXETA, J185ESXETF 1993
J185ESXW 1989
J200CXARC, J200CXARK, J200CXERK, J200CXERS, J200CZARK, J200CZERK, J200CZERS, J200STLERK, J200STLERR, J200TXARC, J200TXARK, J200TXERK, J200TXERS, J200TZARK, J200TZERK, J200TZERS 1994
J200CXATF, J200CXATS, J200CXETD, J200CXETF, J200CZATF, J200CZATS, J200CZETD, J200CZETF, J200STLETC, J200STLETF, J200TXATF, J200TXATS, J200TXETD, J200TXETF, J200TZATF, J200TZATS, J200TZETD, J200TZETF, VJ200SLETC, VJ200SLETF, VJ200TXETD, VJ200TXETF, VJ200TZETD, VJ200TZETF 1993
J200CXCCR, J200STLACM, J200STLCCM, J200TXCCR 1988
J200CXCEA, J200STLCEB, J200TXCEA, TJ200TXCEA 1989
J200CXEIB, J200STLEID, J200TXEIB, VJ200SLEID, VJ200TXEIB 1991
J200CXENE, J200STLENS, J200TXENE, VJ200SLENS, VJ200TXENE 1992
J200CXEOC, J200CZEOC, J200STLEOA, J200TXEOC, J200TZEOC, LJ200SLEOC 1995
J200CXESM, J200STLESE, J200TXESM, VJ200SLESE, VJ200TXESM 1990
J200STLCDR, J200TXCDS 1986
J200STLCUA, J200TXCUC 1987
J225CLCUB, J225CXCUB, J225PLCUB, J225PXCUB, J225TLCUB, J225TXCUB 1987
J225CXARC, J225CXARK, J225CXERK, J225CXERM, J225CZARK, J225CZERK, J225CZERM, J225PLERK, J225PLERM, J225PXARC, J225PXARK, J225PXERK, J225PXERM, J225PZARK, J225PZERK, J225PZERM, J225STLERC, J225STLERK, J225TLERK, J225TLERM, J225TXARC, J225TXARK, J225TXERK, J225TXERM, J225TZARK, J225TZERK, J225TZERM 1994
J225CXATF, J225CXATS, J225CXETA, J225CXETF, J225CZATF, J225CZATS, J225CZETA, J225CZETF, J225PLETA, J225PLETF, J225PXATF, J225PXATS, J225PXETA, J225PXETF, J225PZATF, J225PZATS, J225PZETA, J225PZETF, J225STLETF, J225TLETA, J225TLETF, J225TXATF, J225TXATS, J225TXETA, J225TXETF, J225TZATF, J225TZATS, J225TZETA, J225TZETF, VJ225PLETA, VJ225PLETF, VJ225PXETA, VJ225PXETF, VJ225PZETA, VJ225PZETF, VJ225STLETF, VJ225TLETA, VJ225TLETF, VJ225TXETA, VJ225TXETF, VJ225TZETA, VJ225TZETF 1993
J225CXCCE, J225PLCCE, J225PXCCE, J225TLCCE, J225TXCCE 1988
J225CXCED, J225PLAED, J225PLCED, J225PXCED, J225TLAED, J225TLCED, J225TXCED 1989
J225CXEDE, J225CZEDE, J225PXEDE, J225STLEDE, J225TXEDE, J225TZEDE, SJ225CXEDE, SJ225PXEDE, SJ225SLEDE, SJ225TXEDE 1996
J225CXEIC, J225PLEIC, J225PXEIC, J225TLEIC, J225TXEIC, VJ225PLEIC, VJ225PXEIC, VJ225TLEIC, VJ225TXEIC 1991
J225CXENR, J225PLENR, J225PXENR, J225TLENR, J225TXENR, VJ225PLENR, VJ225PXENR, VJ225TLENR, VJ225TXENR 1992
J225CXEOB, J225CZEOB, J225PXEOB, J225PZEOB, J225STLEOB, J225TXEOB, J225TZEOB 1995
J225CXESS, J225PLASS, J225PLESS, J225PXESS, J225TLASS, J225TLESS, J225TXESS, VJ225PLESS, VJ225PXESS, VJ225TLASS, VJ225TLESS, VJ225TXESS 1990
J225PTLCDA, J225PTXCDA, J225TLCDA, J225TXCDA 1986
J250CXARC, J250CXERC, J250CZERC, J250TXARC, J250TXERC, J250TZERC 1994
J250CXATF, J250CXATS, J250CXETF, J250CXETS, J250CZATF, J250CZATS, J250CZETF, J250CZETS, J250TXATF, J250TXATS, J250TXETF, J250TXETS, J250TZATF, J250TZATS, J250TZETF, J250TZETS 1993
J250CXEIE, J250TXEIE 1991
J250CXEND, J250CZEND, J250TXEND, J250TZEND 1992
J250CXEOR, J250CZEOR, J250TXEOR, J250TZEOR 1995
J275CLCUR, J275CXCUR, J275PLCUR, J275PXCUR 1987
J275CXCCA, J275PLCCA, J275PXCCA 1988
J300CLCUR, J300CXCUR, J300PLCUR, J300PXCUR 1987
J300CXCCA, J300PLCCA, J300PXCCA 1988
J300CXCEM, J300PLCEM, J300PXCEM 1989
J300CXEIE, J300PLEIE, J300PXEIE 1991
J300CXEND, J300PLEND, J300PXEND 1992
J300CXEOR, J300PLEOR, J300PXEOR 1995
J300CXERC, J300PLERC, J300PXERC 1994
J300CXESB, J300PLESB, J300PXESB 1990
J300CXETF, J300CXETS, J300PLETF, J300PLETS, J300PXETF, J300PXETS 1993
Information:
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Required Tools
300-8648 Insulation Testing Gp
349-4206 Insulation Testing Gp Periodically, use an insulation tester to check the insulation resistance of the generators main stator winding. The frequency of this test is determined by the generators environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for A Periodic Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Isolate the stator windings of the generator by disconnecting all other leads and cables from the generator terminals. Isolate the connections to the voltage regulator, the control panel, the switch gear, or other devices.
Connect the insulation testers RED lead to ground.
Connect the insulation testers BLACK lead to the Wye point or star point of the generators windings.
For units that are 600 V or less, set the voltage to 500 V. For units that are more than 600 V, set the voltage to 1000 V.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be corrected for temperature.
Record temperature.
Record humidity.
Remove voltage.
Evaluate the readings. The actual value of the resistance may vary greatly between generators. For this reason, the insulations condition must be evaluated. Base this evaluation on the comparison between the 60 second resistance readings and the readings that were taken on previous dates. These two readings must be taken under similar conditions. If a 60 second resistance reading has a 50 percent reduction from the previous reading, the insulation may have absorbed too much moisture. Switch the insulation tester to the "OFF" position. Switch the insulation tester to the "OFF" position will discharge the insulation testers leads. Disconnect the insulation testers leads.Note: The results from the insulation resistance checks indicate when cleaning and/or repairing is becoming critical. Generally, insulation resistance will vary greatly with temperature. Therefore, always test at the same temperature and humidity. Refer to Illustration 1.Serial Number (Engine)____________________Serial Number (Generator)____________________
Illustration 1 g00633226
Parts oil JOHNSON:
0387397
0387397 OIL LINE ASSY.,Lower
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, 85TXLR77S, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, C
0389836
0389836 OIL PUMP ASSY
100ML79S, 115ML79R, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 85ML79R, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, BJ25ARECA, BJ25AREDC, BJ25AREUR, BJ25PL3EEM, BJ25PL3SIE, BJ25PL3SSB, BJ35ARECR, BJ35AREDS, BJ35AREEA, BJ35AREUC, BJ35E3SIE, BJ35E3SSB,
0390443
0390443 OIL LINE ASSY.,Upper
D100WTLM, J100MLCSC, J100STLCCA, J100STLCEM, J100STLESB, J100WMLCDR, J100WMLCOC, J100WMLCRS, J100WTLCUA, J100WTLEDR, J100WTLEIB, J100WTLENE, J100WTLEOC, J100WTLERS, J100WTLESM, J100WTLETD, J100WTLEUA, J100WTLZ, J110MLCCA, J110MLCDC, J110MLCEM, J110ML
0984142
0984142 OIL FILTER ASSY.
BJ200CXEDR, CJ275TLCDC, CJ300TLCDC, J185ESERK, J185ESXENR, J185ESXESS, J185ESXETA, J185ESXW, J200CXARC, J200CXATF, J200CXCCR, J200CXCEA, J200CXEIB, J200CXENE, J200CXEOC, J200CXESM, J200STLCDR, J200STLCUA, J225CLCUB, J225CXARC, J225CXATF, J225CXCCE, J
0174638
0175097
0175097 OIL PICKUP ASSEMBLY
J100STLEIE, J100STLEND, J100STLESB, J100WTLEIB, J100WTLENE, J115JLEIE, J115JLEND, J115MLESB, J120TLAIE, J120TLAND, J125ESXENR, J125ESXESS, J140CXEIA, J140CXENM, J150CXEIE, J150CXESB, J150ELAIS, J150ELANC, J150STLEIE, J155WTLEIB, J155WTLENE, J175EXEIS
0175000
0175000 OIL TANK KIT
J100STLEIE, J100STLEND, J100STLESB, J100WTLEIB, J100WTLENE, J115JLEIE, J115JLEND, J115MLESB, J120TLAIE, J120TLAND, J125ESXENR, J125ESXESS, J140CXEIA, J140CXENM, J150CXEIE, J150CXESB, J150ELAIS, J150ELANC, J150STLEIE, J155WTLEIB, J155WTLENE, J175EXEIS
0175095