0327769 JOHNSON ORIFICE PLUG, (No. 70D)


0327769 ORIFICE PLUG, (No. 70D) JOHNSON BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, J125WTPLE, J130CXAOR, J150CXEES, J150CXSSC, J150ELARA, J150ELEOM, J150 ORIFICE
0327769 ORIFICE PLUG, (No. 70D) JOHNSON
Rating:
93

Buy ORIFICE PLUG, (No. 70D) 0327769 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 15
 

BRP JOHNSON entire parts catalog list:

BJ130PLEED, BJ130PXEED, J130PLEED, J130PXEED 1999
BJ130PLSSS, BJ130PXSSS, J130PLSSS, J130PXSSS, J130VXSSS, RJ130PLSSS, RJ130PXSSS, RJ130VXSSS 2000
BJ130TLECE, HJ130TXACB, J130TLECE, J130TXACB 1998
BJ130TLEDM, HJ130CXADA, HJ130TXADA, J130TLEDM, J130TXADA, SJ130CXADA, SJ130TLEDM, SJ130TXADA 1996
BJ130TLEUB, HJ130CXAUM, HJ130TXAUM, J130TLEUB, J130TXAUM 1997
BJ135PLSIF, BJ135VXSIF, J135PLSIF, J135VLSIF, J135VXSIF, RJ135PLSIF, RJ135VXSIF 2001
BJ150ELECD, BJ150EXECD, BJ150GLECD, BJ150NXECD, J150ELECD, J150EXECD, J150GLECD, J150JLECD, J150NXECD, J150SLECD 1998
BJ150ELEDB, BJ150EXEDB, BJ150GLEDB, BJ150NXEDB, J150ELEDB, J150EXEDB, J150GLEDB, J150JLEDB, J150NXEDB, J150SLEDB, SJ150ELEDB 1996
BJ150ELEUC, BJ150ELEUE, BJ150EXEUC, BJ150EXEUE, BJ150GLEUC, BJ150GLEUE, BJ150NXEUC, BJ150NXEUE, J150ELEUC, J150ELEUE, J150EXEUC, J150EXEUE, J150GLEUC, J150GLEUE, J150JLEUC, J150JLEUE, J150NXEUC, J150NXEUE, J150SLEUC, J150SLEUE 1997
BJ175EXECD, BJ175GLECD, BJ175NXECD, J175EXECD, J175GLECD, J175NXECD, J175SLECD 1998
BJ175EXEDB, BJ175GLEDB, BJ175NXEDB, J175EXEDB, J175GLEDB, J175NXEDB, J175SLEDB 1996
BJ175EXEUC, BJ175EXEUE, BJ175GLEUC, BJ175GLEUE, BJ175NXEUC, BJ175NXEUE, J175EXEUC, J175EXEUE, J175GLEUC, J175GLEUE, J175NXEUC, J175NXEUE, J175SLEUC, J175SLEUE 1997
BJ175PLEES, BJ175PXEES, J175CXEES, J175PLEES, J175PXEES, J175SPLEES 1999
BJ175PLSIF, BJ175VXSIF, J175PLSIF, J175VCXSIF, J175VLSIF, J175VXSIF, RJ175CXSIF, RJ175PLSIF, RJ175VXSIF 2001
BJ175PLSSC, BJ175PXSSC, BJ175VXSSS, J175CXSSS, J175PLSSC, J175PXSSC, J175SPLSSC, J175VCXSSS, J175VLSSS, J175VXSSS, RJ175CXSSS, RJ175PLSSC, RJ175VXSSS 2000
J125WTPLE 1995
J130CXAOR, J130TLEOA, J130TXAOR 1995
J150CXEES, J150JPLEES, J150PLEES, J150PXEES, J150SPLEES 1999
J150CXSSC, J150JPLSSC, J150MXSSD, J150PLSSC, J150PXSSC, J150SPLSSC, J150VCSSS, J150VLSSS, J150VXSSS, RJ150CXSSC, RJ150PLSSC, RJ150PXSSC, RJ150VCSSS, RJ150VLSSS, RJ150VXSSS 2000
J150ELARA, J150ELARV, J150ELERA, J150ELERV, J150EXARC, J150EXARV, J150EXERA, J150EXERV, J150GLERA, J150GLERV, J150JLERA, J150JLERV, J150NXARC, J150NXARV, J150NXERA, J150NXERV 1994
J150ELEOM, J150EXEOM, J150GLEOM, J150JLEOM, J150NXEOM, J150SLEOM, VJ150HLEOS 1995
J150JPLSIF, J150PLSIF, J150VCXSIF, J150VLSIF, J150VXSIF, RJ150PLSIF, RJ150VCSIF, RJ150VLSIF, RJ150VXSIF 2001
J175EXARC, J175EXARV, J175EXERA, J175EXERV, J175GLERA, J175NXARC, J175NXARV, J175NXERA, J175NXERV, J175SLERA 1994
J175EXEOM, J175GLEOM, J175NXEOM, J175SLEOM 1995
J30ECCE, J30ELCCE, J30RCCE, J30RLCCE, J30TECCE, J30TELCCE 1988
J35RCCE, J35RLCCE 1988
SJ125WTPLJ, SJ125WTPXJ 1997
SJ125WTPLN, SJ125WTPXN 1998
SJ125WTPLV, SJ125WTPXV 1996

Information:


Table 1
Parameter Default Value Valid Range
Governor Gain Factor 100% 0.1% - 1,000%
Governor Minimum Stability Factor 100% 0.1% - 1,000%
Governor Maximum Stability Factor 100% 0.1% - 1,000% Note: No engineering units are associated with the numbers in table 1.Note: The range of the programmable setting is wide for flexibility. Do not expect to use the whole range. If the programmable setting is greater than the valid range, the system will revert to the factory default value.Do not perform this procedure until you read this information and you understand this information.Gain Explanations
Governor Gain Factor
The "Governor Gain Factor" is multiplied by the engine speed error. This value is derived by calculating the difference between the desired speed and the actual speed.
If the "Governor Gain Factor" value is too large, the engine speed can overshoot the desired speed.
If the "Governor Gain Factor" value is too small, the engine will accelerate slowly.Governor Minimum/Maximum Stability Factor
The "Governor Minimum Stability Factor" functions to eliminate steady state speed error. The "Governor Minimum Stability Factor" is used by the Electronic Control Module (ECM) when the steady state speed error is less than 20 rpm.The "Governor Maximum Stability Factor" functions to eliminate steady state speed error. The "Governor Maximum Stability Factor" is used by the ECM when the steady state speed error is increasing and the engine speed error is greater than 20 rpm.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too high, the ECM will provide more fuel. The additional fuel will cause the engine speed to overshoot. The additional fuel will also cause the engine speed to oscillate.
If the "Governor Minimum Stability Factor" or the "Governor Maximum Stability Factor" is set too low, the engine will not achieve a steady state operation quickly.Tuning Procedure
Turn the Engine Control Switch (ECS) to the COOLDOWN/STOP position. Connect the Caterpillar Electronic Technician (ET). Enable the engine overspeed protection prior to the adjustment procedure. Adjusting governor gain parameters without engine overspeed protection can result in serious engine damage. Ensure that engine overspeed protection is ON. Engine overspeed is configured on the setup screen of "Service Monitoring System" in Cat ET.
Personal injury or death can result from engine overspeed.If the engine overspeeds, it can cause injury or parts damage. The engine should be equipped with a separate shutdown device, to protect against engine overspeed. Do not use for emergency shutdown.
Start the engine. Observe the control panel to ensure that the engine has reached the rated speed. The control panel will serve as the reference point for engine speed during this procedure.
Go to the configuration parameters screen in Cat ET.Note: A factory password is required for adjustment of the governor gain parameters. Once the password is entered, the values for the governor gain parameters can be adjusted. If a parameter value that is not a governor gain parameter is altered, a new password will be required. If the configuration parameters screen is stopped during the adjustment of a governor gain parameter, a new factory password will be required.Note: Any value may be returned to the factory default setting by typing a number that is greater than the valid range. For example, typing 40,000 will reset a value to the factory default.
Set up a field performance test. For example, the engine has poor response during specific load changes.
Perform the desired load change from step 4. Observe the response of the engine by viewing the engine speed on the control panel. Observe the engine response by looking at the frequency meter or by listening to the response of the engine.
Determine the setting to adjust. Refer to "Gain Explanations" and "Governor Minimum/Maximum Stability Factor".Note: Usually, the "Governor Gain Factor" should be lower than the "Governor Minimum Stability Factor" for optimum performance. The "Governor Maximum Stability Factor" is typically a smaller value than the "Governor Minimum Stability Factor" and "Governor Gain Factor".
Repeat steps 5,6, and 7 until a desired engine response can be met. Use large adjustments (ten percent of original gain) initially for a coarse adjustment to engine response. Use smaller adjustments (one percent of total gain) as the engine response is closer to the desired response.


Parts orifice JOHNSON:

0317473
 
0317473 ORIFICE, Idle
100ML79S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL72R, 135ESL73M, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 175TL78C, 200TL78R, 235TL78R, 55E77D, 55E78S, 70EL76D, 70ES74M, 70ES75B, 75ELR76D, 85ETLR78C, 85ML79R,
0320015
ORIFICE, Idle rstr. (#33)
0320015 ORIFICE, Idle rstr. (#33)
115TXL77S, 140ML77S, 150TL78S, 175TL78C, 200TL78R, 235TL78R, 70ES74M, 70ES75B, 85TXLR77S, BJ3REDS, BJ4BREDS, BJ4BREUC, BJ4RDHEDS, BJ5DREDS, BJ5DREUC, BJ6DRECR, BJ6DREDS, BJ6DREUC, BJ8REDS, CJ275TLCDC, CJ300TLCDC, J120TLARC, J125ESXERK, J125WTPLE, J13
0319831
 
0319831 ORIFICE PLUG
25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, BJ150ELECD, BJ150ELEUC, BJ175EXECD, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEUD,
0323003
ORIFICE, Idle, 85 HP
0323003 ORIFICE, Idle, 85 HP
100ML79S, 115EL77S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 85EL77S, 85ETLR78C, 85ML79R, 85TXLR77S, BJ115TLEDA, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, HJ88MSLE
0322936
ORIFICE,Idle,140 hp port
0322936 ORIFICE,Idle,140 hp port
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 85ETLR78C, 85ML79R, 85TXLR77S, J100MLCSC, J115MLCIH, J115MLCSA, J120TLCDC, J120TLCUR, J140MLCIH, J140MLCSA, J140TLCDC, J140TLCUA, J150ELAIS, J150ELANC, J150ELARA, J150ELATG, J155
0322907
 
0322907 ORIFICE PLUG 57D
50R79C, 55E79C, AM55RSLD, BJ150ELEDB, BJ175EXEDB, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BA
0328546
 
0328546 ORIFICE, High speed, #72D, 175
BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, J150CXSNF, J150ELAIS, J150ELANC, J150ELARA, J150ELATG, J175CXSNF, J175EXARC, J175EXATG, J175EXEIS, J175EXENC, J185ESERK, J200CXARC, J200CXECM, J200CXEOC, J200CXEUA, J
0327560
 
0327560 ORIFICE, High speed No. 75D, 140
J120TLARC, J125ESXERK, J130CXAOR, J140CXARC, J200CXECM, J225CXECS, J250CXECD
Back to top