0209364 JOHNSON OWNER'S MANUAL 75 TNT


0209364 OWNER'S MANUAL 75 TNT JOHNSON J70ELCIH, J75ERCIH OWNER
0209364 OWNER'S MANUAL 75 TNT JOHNSON
Rating:
23

Buy OWNER'S MANUAL 75 TNT 0209364 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 20936
 

Compatible models:

BRP JOHNSON entire parts catalog list:

J70ELCIH, J70ELCIM, J70TLCIM 1981
J75ERCIH, J75ERCIM, J75ERLCIH, J75ERLCIM, J75TELCIM, J75TRLCIH 1981

Information:


Table 1
Diagnostic Codes Table    
Description    Conditions which Generate this Code    System Response    
1501-3 Cylinder #1 Detonation Sensor : Voltage Above Normal     The Electronic Control Module (ECM) has detected a voltage on the signal line of the sensor that is greater than the trip point for more than ten seconds.     The code is logged.
The alarm output is activated.
The shutdown output is activated.
The engine is shut down.    
1501-4 Cylinder #1 Detonation Sensor : Voltage Below Normal  


Parts owner JOHNSON:

0209092
0209184
 
0209184 OWNER'S MANUAL 75 TNT
J70ELCIH, J75ERCIH
0390506
0391606
 
0391606 OWNER'S MANUAL 75 TNT
J70ELCIH, J75ERCIH
0391975
0391978
 
0391978 OWNER'S MANUAL 75 TNT
J70ELCIH, J75ERCIH
Back to top