0211691 PLATE, Frame, rear, 20 JOHNSON
J20CREIE, J20CREND, J20CRETS, J25REIE, J25REND, J25RETS, J30REIC, J30RENR, J30RETA, J35REIC, J35RENR, J35RETA
PLATE
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- ENGINE COVER - EVINRUDE » 0211691
J20CRETS, J20CRLETS, TJ20CRETS, TJ20CRLETS 1993
J25REIE, J25RLEIE, VJ25REIE 1991
J25REND, J25RLEND 1992
J25RETS, J25RLETS 1993
J30REIC, J30RLEIC 1991
J30RENR, J30RLENR 1992
J30RETA, J30RLETA 1993
J35REIC, J35RLEIC 1991
J35RENR, J35RLENR 1992
J35RETA, J35RLETA 1993
Information:
Air Compressors:
BHP = 1/4 × cu. ft. per minute at 100 psi Increase BHP 10% for 125 psiDecrease BHP 10% for 80 psiAMA HP for U.S.A. Tax Purposes:
Where: N = No. of Cylinders D = Piston Diameter in inchesBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline.
Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1/2 Sq. ft. surface area per HPWith 85°F flowing raw waterElectricity:
Generator Capacity Required: Motors:1 kW per nameplate HP (motor running cool or warm to touch)11/4 kW per nameplate HP (motor running hot to touch)Horsepower Requirements: 11/2 BHP per kW of load or Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 5.5 × BHPInrush Current (Code F motor)= 6.2 × Full load rated current1 kVa per HP at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow - 150°CFM per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-phase ratingGenerator Temperature Rise: Increase 1°C for each 330 feet above 3300 feetFuel Consumption
Gas Compressor:
BHP = 22 RcVSWhere: Rc = Stage Compression RatioV = Million cu. ft./dayS = Number of StagesHeat Rejection
% of Fuel Energy Consumed Jacket Water Prechambered engines BTU/min = 36 × BHPDirect injection engines BTU/min = 27 × BHP Hours Per:
Year = 8760 (365 Days)Week = 168 (7 Days)Month = 720 (30 Days)Oilfield Drilling:
Hoisting Mud Pumps Rotary Table On Site Power Requirements:
Based on 100,000 sq. ft. of office bldg., etc., and 40°N. latitudes Electric Requirements: 600 kW continuous load(air conditioning is absorption)Use three - 300 kW units (2 prime and 1 standby)Air Conditioning Compressor 400 tons prime loadUse two - 200 HP engines (No standby)Pumps:
Pipe Line BHP = Barrels per hour × psi × 0.00053 *Efficiency Refrigeration
One ton refrigeration = 200 BTU/Min. = 12,000 BTU/Hr.One boiler HP = 33,475 BTU/Hr.One ton compressor rating = One Engine HPAuxiliary air conditioning equipment requires 1/4 HP per ton of compressor ratingIce Plant: Complete power requires 4-5 HP per daily ton capacitySawmill:
11/2 BHP per inch of saw diameter at 500 RPM Increase or decrease in proportion to RPMSwing Cut-Off Saw Table Trimmer 71/2 to 10 BHPBlower Fan 12-foot sawdust 3 to 5 BHPPlaner Mill 2 to 4 BHP per 100 board feet per hour 24 to 30-inch planers 15 to 25 BHPEdgers Approximate fuel consumption: Softwood 1 gal. per 1000 board feetHardwood 1 gal. per 750 board feetPropellor Shaft Size Selection:
For intermediate shaft and tailshaft in marine installations Where: D = Diameter in inchesHP = HorsepowerS = Torsional stress in PSI (usually 5000)Shovels and Draglines:
Use manufacturer's recommendations. Torque: (4 cycle only) Torque Converters:
Peak output shaft horsepower: Normally 80% of input horsepower for either single or three-stage converterOutput shaft speed at peak output horsepower: Single-stage - 0.7 to 0.85 engine full load speedThree-stage - 0.5 to 0.6 engine full load speedTorque multiplication at or near stall: Single-stage - 2.2 to 3.4 times engine torqueThree-stage - 3.6 to 5.4 times engine torqueVentilation:
Natural 1/2 net square inch for each BHPBlown 1/3 net square inch for each BHPMetric Units
Air Compressors:
110 kW = 1 m3/min @ 850 kPa100 kW = 1 m3/min @ 675 kPa90 kW = 1 m3/min @ 550 kPaAMA Power for U.S.A. Tax Purposes:
Where: N = No. of CylindersD = Piston Diameter in millimetersBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline. Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1 m2 surface area per 16 kW with 30°C flowing raw waterElectricity:
Generator Capacity Required: Motors:11/3 kW per nameplate kW (motor running cool or warm to touch)12/3 kW per nameplate kW (motor running hot to touch)Engine Power Requirements: Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 41/8 × nameplate kWInrush Current (Code F motor) = 6.2 × full load rated current11/3 kVa per kW at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow = 41/4 m3 per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-Phase ratingGenerator Temperature Rise: Increase 1°C for each 100 meters above 1000 metersFuel Consumption
3*33 720 kJ/mGas Compressor:
kW = 777 Rc VSWhere : Rc = Stage Compression RatioV = Millions cubic meters per dayS = Number of Stages
BHP = 1/4 × cu. ft. per minute at 100 psi Increase BHP 10% for 125 psiDecrease BHP 10% for 80 psiAMA HP for U.S.A. Tax Purposes:
Where: N = No. of Cylinders D = Piston Diameter in inchesBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline.
Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1/2 Sq. ft. surface area per HPWith 85°F flowing raw waterElectricity:
Generator Capacity Required: Motors:1 kW per nameplate HP (motor running cool or warm to touch)11/4 kW per nameplate HP (motor running hot to touch)Horsepower Requirements: 11/2 BHP per kW of load or Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 5.5 × BHPInrush Current (Code F motor)= 6.2 × Full load rated current1 kVa per HP at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow - 150°CFM per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-phase ratingGenerator Temperature Rise: Increase 1°C for each 330 feet above 3300 feetFuel Consumption
Gas Compressor:
BHP = 22 RcVSWhere: Rc = Stage Compression RatioV = Million cu. ft./dayS = Number of StagesHeat Rejection
% of Fuel Energy Consumed Jacket Water Prechambered engines BTU/min = 36 × BHPDirect injection engines BTU/min = 27 × BHP Hours Per:
Year = 8760 (365 Days)Week = 168 (7 Days)Month = 720 (30 Days)Oilfield Drilling:
Hoisting Mud Pumps Rotary Table On Site Power Requirements:
Based on 100,000 sq. ft. of office bldg., etc., and 40°N. latitudes Electric Requirements: 600 kW continuous load(air conditioning is absorption)Use three - 300 kW units (2 prime and 1 standby)Air Conditioning Compressor 400 tons prime loadUse two - 200 HP engines (No standby)Pumps:
Pipe Line BHP = Barrels per hour × psi × 0.00053 *Efficiency Refrigeration
One ton refrigeration = 200 BTU/Min. = 12,000 BTU/Hr.One boiler HP = 33,475 BTU/Hr.One ton compressor rating = One Engine HPAuxiliary air conditioning equipment requires 1/4 HP per ton of compressor ratingIce Plant: Complete power requires 4-5 HP per daily ton capacitySawmill:
11/2 BHP per inch of saw diameter at 500 RPM Increase or decrease in proportion to RPMSwing Cut-Off Saw Table Trimmer 71/2 to 10 BHPBlower Fan 12-foot sawdust 3 to 5 BHPPlaner Mill 2 to 4 BHP per 100 board feet per hour 24 to 30-inch planers 15 to 25 BHPEdgers Approximate fuel consumption: Softwood 1 gal. per 1000 board feetHardwood 1 gal. per 750 board feetPropellor Shaft Size Selection:
For intermediate shaft and tailshaft in marine installations Where: D = Diameter in inchesHP = HorsepowerS = Torsional stress in PSI (usually 5000)Shovels and Draglines:
Use manufacturer's recommendations. Torque: (4 cycle only) Torque Converters:
Peak output shaft horsepower: Normally 80% of input horsepower for either single or three-stage converterOutput shaft speed at peak output horsepower: Single-stage - 0.7 to 0.85 engine full load speedThree-stage - 0.5 to 0.6 engine full load speedTorque multiplication at or near stall: Single-stage - 2.2 to 3.4 times engine torqueThree-stage - 3.6 to 5.4 times engine torqueVentilation:
Natural 1/2 net square inch for each BHPBlown 1/3 net square inch for each BHPMetric Units
Air Compressors:
110 kW = 1 m3/min @ 850 kPa100 kW = 1 m3/min @ 675 kPa90 kW = 1 m3/min @ 550 kPaAMA Power for U.S.A. Tax Purposes:
Where: N = No. of CylindersD = Piston Diameter in millimetersBrake Mean Effective Pressure:
Conveyors: 15 to 20° incline. Cooling:
Heat Exchanger Flow Rate Raw water to jacket water 1:1 to 2:1Submerged Pipe Cooling 1 m2 surface area per 16 kW with 30°C flowing raw waterElectricity:
Generator Capacity Required: Motors:11/3 kW per nameplate kW (motor running cool or warm to touch)12/3 kW per nameplate kW (motor running hot to touch)Engine Power Requirements: Electric Sets:
Motor Starting Requirements: Inrush kVa (Code F motor) = 41/8 × nameplate kWInrush Current (Code F motor) = 6.2 × full load rated current11/3 kVa per kW at full loadGenerator full load rated current capacity: Generator Cooling Requirements: Air Flow = 41/4 m3 per kW loss × efficiencyCircuit Breaker Trip Selection: 1.15 to 1.25 × full load generator amp ratingSingle Phase Rating of 3-Phase Generator: 60% of 3-Phase ratingGenerator Temperature Rise: Increase 1°C for each 100 meters above 1000 metersFuel Consumption
3*33 720 kJ/mGas Compressor:
kW = 777 Rc VSWhere : Rc = Stage Compression RatioV = Millions cubic meters per dayS = Number of Stages
Parts plate JOHNSON:
0324318
0324318 PLATE,Leaf
25E79R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEUD, BJ30EECS, BJ30EEDE, BJ30EEEC,
0328755
0328755 PLATE,Impeller housing
BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25ARECA, BJ25AREDC, BJ25AREUR, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ25PL3EEM, BJ25PL3SIE, BJ25PL3SSB, BJ30BAECS, BJ30BAEDE
0327944
0327944 PLATE,Throttle control
BJ10EEDD, BJ10FAEDC, BJ10FAEUR, BJ10RELEUS, BJ10RHLSDA, BJ10RHLSOR, BJ10RHLSRC, BJ10RHLSTS, BJ15EEDS, BJ15RELEUC, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25ARECA, BJ25AREDC, BJ25AREUR, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25PL3EEM, BJ25PL3SIE, BJ25PL3SSB, B
0211233
0211233 PLATE, Frame, front, 35
J20CRCEM, J20CREIE, J20CRESB, J25RCEM, J25REIE, J25RESB, J30RCED, J30REIC, J30RESS, J35RCED, J35REIC, J35RESS
0211222
0211222 PLATE, Frame, front, 20
J20CRCEM, J20CREIE, J20CRESB, J20ECEM, J20EEIE, J20EESB, J25ECEB, J25EEID, J25EESE, J25RCEM, J25REIE, J25RESB, J30ECED, J30EEIC, J30EESS, J30RCED, J30REIC, J30RESS, J35RCED, J35REIC, J35RESS, TJ30ELESS
0211231
0211231 PLATE, Frame, front, 30
J20CRCEM, J20CREIE, J20CRESB, J20ECEM, J20EEIE, J20EESB, J25ECEB, J25EEID, J25EESE, J25RCEM, J25REIE, J25RESB, J25TECEM, J25TEEIE, J25TEESB, J30ECED, J30EEIC, J30EESS, J30RCED, J30REIC, J30RESS, J30TECED, J30TEEIC, J30TEESS, J35RCED, J35REIC, J35RESS
0335788
0335788 PLATE, Frame, rear, 25
J20CREIE, J20EEIE, J25EEID, J25REIE, J25TEEIE, J30EEIC, J30REIC, J30TEEIC, J35REIC
0337618
0337618 PLATE, Frame, front
J20CREND, J20CRERC, J20CRETS, J25REND, J25RERC, J25RETS, J30RENR, J30RERM, J30RETA, J35RENR, J35RERM, J35RETA