0315583 JOHNSON PLATE, Impeller housing


0315583 PLATE, Impeller housing JOHNSON 55ES69A, 60ES70B, 60ES71C PLATE

Buy PLATE, Impeller housing 0315583 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$36.50
 

26-02-2024
5.6[2.52] Pounds
US: LEADERS RPM
Johnson/Evinrude/OMC New OEM PLATE 0315583, 315583
Johnson Evinrude OMC SKU: 0315583 || Sold Each || Please verify your own fitment
Number on catalog scheme: 91
 

Compatible models:

BRP JOHNSON entire parts catalog list:

55ES69A, 55ES69C, 55ESL69A, 55ESL69C 1969
60ES70B, 60ES70D, 60ESL70B, 60ESL70D 1970
60ES71C, 60ES71E, 60ESL71C, 60ESL71E 1971

Information:

7G7889 12V 60A (Delco-Remy Number 1117641)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 13.6 1.0VOutput (cold) ... 62A(1) Torque for the ground terminal nut ... 2.3 0.6 N m (21 5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)9G5235 Regulator (Delco-Remy Number 1116407) Inside Alternator
Voltage Setting ... No adjustmentPermissible voltage range ... 13 to 15V5N5692 24V 45A (Delco-Remy Number 1117642)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 27.5 1.0VOutput (cold) ... 45A(1) Torque for the ground terminal nut ... 2.3 0.6 N m (21 5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6353 Regulator (Delco-Remy Number 1984287) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30V3T6352 24V 35A (Delco-Remy Number 1117647)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2.5 lb in)(2) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(3) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)3T6353 Regulator (Delco-Remy Number 1984287) Inside Alternator
Voltage setting ... No adjustmentPermissible voltage range ... 26 to 30VDelco-Remy (25SI)
5S6698 12V 75A (Delco-Remy Number 1117242)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output (cold) ... 70A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 7.1 0.9 N m (64 8 lb in)7N284 Regulator (Delco-Remy Number 1892813) Inside Alternator
Voltage setting range ... 13 to 15VAdjust voltage setting to ... 14V There are two types of adjustment: One type of adjustment is made by removing a pipe plug and turning the adjusting screw one or two notches in a clockwise direction to increase the voltage setting or one or two notches in a counterclockwise direction to decrease the voltage setting. The second type of adjustment is similar except, remove the end cover to expose the potentiometer for adjustment.Then increase speed to get a maximum output of ... 75ADelco-Remy (30SI)
4N3986 24V 60A (Delco-Remy Number 1117734)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 27.5 1.0VOutput (cold) ... 60A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 6.8 8.0 N m (60 72 lb in)3T6354 Regulator (Delco-Remy Number 1116405) Inside Alternator
Voltage setting range ... 26 to 30VRated voltage ... 28V(A) Adjust the voltage with the four-position cap. Lo ... Low2 ... Medium Low3 ... Medium HighHi ... High4N3987 32V 60A (Delco-Remy Number 1117733)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 6500Output voltage ... 36.6 1.3VOutput (cold) ... 60A(1) Torque for the pulley nut ... 102 7 N m (76 5 lb ft)(2) Torque for the output terminal nut ... 6.8 8.0 N m (60 72 lb in)3T6354 Regulator (Delco-Remy Number 1116405) Inside Alternator
Voltage setting range ... 33 to 39VRated voltage ... 37.5V(A) Adjust the voltage with the four-position cap. Lo ... Low2 ... Medium Low3 ... Medium HighHi ... HighHi position is for 16 cell battery system (32V). For 15 cell battery system, pull out the four position cap and change to position 3 for 30V.Bosch
7N9720 24V 35A (Bosch Number 0-122-469-001)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 42A(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut B+ ... 17 to 22 N m (13 to 16 lb ft)(3) Torque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)9G7567 Regulator (Bosch Number 1-197-011-000) Under alternator cover. For use with the 7N9720 Alternator.
Voltage rating ... 28VPolarity ... Negative groundVoltage setting range ... 26.7 to 28.3VNippondenso
9G4574 24V 35A (Nippondenso Number 100211-0860)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 35A(1) Torque for the pulley nut ... 95 to 110 N m (70 to 80 lb ft)(2) Torque for the output terminal nut ... 22 to 37 N m (16 to 27 lb ft)(3) Torque for the ground terminal nut ... 3.4 to 5.4 N m (31 to 49 lb in)7T2798 Regulator (Nippondenso Number 126000-0380) - Inside Alternator
Voltage setting ... No AdjustmentPermissible voltage range ... 26.5 to 28.5VMotorola
6T1395 24V 35A (Motorola Number 8HC3022F)
Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.6 0.4VOutput (cold) ... 33A min.Torque for the pulley nut ... 53 to 67 N m (40 to 50


Parts plate JOHNSON:

0314768
0314703
0315593
 
0315593 PLATE, Upper applique, port
115ESL70D, 25R70C, 40E70A, 40ES70A, 60ES70B, 85ESL70B
0315594
 
0315594 PLATE, Upper applique, starboard
115ESL70D, 25R70C, 40E70A, 40ES70A, 60ES70B, 85ESL70B
0315597
 
0315597 PLATE, Flagstaff, port and starboard
25R70C, 40E70A, 40ES70A, 60ES70B
0315910
0315911
Back to top