0306392 PLUG,Core JOHNSON
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, RD-30A, RDS-30A, RK-30A, RX-16M, VX-14B
PLUG
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BRP JOHNSON entire parts catalog list:
33E69A, 33EL69A, 33R69A, 33RL69A 1969
33E70M, 33EL70M, 33R70M, 33RL70M 1970
33E70M, 33EL70M, 33R70M, 33RL70M 1970
40E69R, 40EL69R 1969
40E70A, 40EL70A 1970
40E71B, 40E71G, 40EL71B, 40EL71G, 40R71B, 40R71G, 40RL71B, 40RL71G 1971
40E72E, 40EL72E, 40R72E, 40RL72E 1972
40E73D, 40EL73D, 40R73D, 40RL73D 1973
40E74S, 40EL74S, 40R74S, 40RL74S 1974
40E75C, 40EL75C, 40R75C, 40RL75C 1975
40E76A, 40E76R, 40EL76A, 40EL76R, 40R76A, 40R76R, 40RL76A, 40RL76R 1976
40ES69R, 40ESL69R 1969
40ES70A, 40ESL70A 1970
40R69R, 40RL69R 1969
40R70A, 40RL70A 1970
RD-30A, RD-30D, RD-30S, RDL-30A, RDL-30D, RDL-30S 1968
RDS-30A, RDS-30C, RDS-30D, RDS-30S, RDSL-30A, RDSL-30C, RDSL-30D, RDSL-30S 1968
RK-30A, RK-30C, RK-30D, RKL-30A, RKL-30C, RKL-30D 1968
RX-16M, RX-16R, RXE-16M, RXE-16R, RXEL-16M, RXEL-16R, RXL-16M, RXL-16R 1968
VX-14B, VXH-14B, VXHL-14B, VXL-14B 1968
Information:
Table 1
Required Tools    
Tool     Part Number     Part Description     Qty    
A     138-7575     Link Brackets     2    
B     6V-6146     Load Leveler Gp     1    
189-0410 Shackle As     2    
C     1U-9200     Lever Puller Hoist     1    
D     138-7574     Link Bracket     2    
E     308-3470     Jack Stand Gp     2    
F     308-3471     Jack Stand Gp     2    
G     5P-1275     Lockwire (1)     2    
314-8478 Lockwire Tool     1    
H     155-0695     Thread Lock Compound     -    
J     213-9121     O-Ring Assembly Compound     -    
( 1 ) Cut the lockwire to a length 200.0 mm (7.87 inch). Start By:
Release hydraulic system pressure.
Remove the hood.
Remove bottom guards.
Remove the engine side guards.
Fully tilt the cab.
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the work tools have been lowered to the ground, and the oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
Refer to Operation and Maintenance Manual, "Hydraulic System Oil - Change" for the correct draining and filling procedures.
Refer to Operation and Maintenance Manual, "Cooling System Coolant (ELC) - Change" for the correct draining and filling procedures.
Refer to Operation and Maintenance Manual, "Engine Oil and Filter - Change" for the correct draining and filling procedures.
Refer to Operation and Maintenance Manual, "Power Train Oil - Change" for the correct draining and filling procedures.
Perform the Electrical Shutdown and Voltage Discharge procedure.
Illustration 1 g01827514
Remove tube (1) . Disconnect hose assembly (2) . Disconnect hoses (3) from the water pump.
Illustration 2 g01827534
Disconnect hose assembly (4) . Disconnect clips (5) . Disconnect harness assembly (6) .
Illustration 3 g01827537
Disconnect harness assemblies (8) . Disconnect clips (7) in order to reposition harness assemblies (8) . Remove hose (9) .
Illustration 4 g01827533
Disconnect clips (10) . Disconnect harness assemblies (11) . Disconnect hose assembly (12) and tube assembly (13) .
Parts plug JOHNSON:
0301732
0301732 PLUG,Oil hole
1R69C, 1R70R, 2R71A, 2R72M, 2R73B, 2R74E, 2R75D, 2R76S, 2R77C, 2R78R, 2R79A, 33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, 6R69M, 6R70B, 6R71E, 9R69S, 9R70A, 9R71R, 9
0304105
0304105 PLUG,Fuel passage
33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40ES69R, 40ES70A, 40R69R, 40R70A, FD-22A, RD-30A, RDS-30A, RK-30A, RX-16M
0307769
0307769 PLUG, Cable entrance
40R69R, 40R70A, AM55RSLD, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECOB, J40ECUD, J40WREES, J40WRLSIR, J40WRLSSC, J45RCCDS, J45RCCUC, J45RCE, J45RCEIA, J45RCENM, J45RCEOD, J45RCERE, J45RCESR, J45RCETB,
0307541
0307463
0305073
0305124
0305124 PLUG,Water passage
100ESL71A, 115ESL69E, 115ESL70D, 125ESL71C, 85ESL69E, 85ESL70B, 85ESL71A, V4A-20A, V4S-20A, V4T-14B, VX-14B
0306044