0329428 PLUG, Lower motor cover JOHNSON
J6RCDE, J6RESR, J8RCDE, J8RESR
PLUG
Price: query
Rating:
BRP JOHNSON entire parts catalog list:
J6RESR, J6RLESR, J6SLESR 1990
J8RCDE, J8RLCDE, J8SRLCDE 1986
J8RESR, J8RLESR, J8SRLESR 1990
Information:
Table 1
Diagnostic Codes Table
J1939 Code and Description Conditions which Generate this Code System Response
1352-3
Engine Cylinder #1 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1352-4
Engine Cylinder #1 Knock Level : Voltage Below Normal
1352-19
Engine Cylinder #1 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1353-3
Engine Cylinder #2 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1353-4
Engine Cylinder #2 Knock Level : Voltage Below Normal
1353-19
Engine Cylinder #2 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1354-3
Engine Cylinder #3 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1354-4
Engine Cylinder #3 Knock Level : Voltage Below Normal
1354-19
Engine Cylinder #3 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1355-3
Engine Cylinder #4 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1355-4
Engine Cylinder #4 Knock Level : Voltage Below Normal
1355-19
Engine Cylinder #4 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1356-3
Engne Cylinder #5 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1356-4
Engine Cylinder #5 Knock Level : Voltage Below Normal
1356-19
Engine Cylinder #5 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1357-3
Engine Cylinder #6 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1357-4
Engine Cylinder #6 Knock Level : Voltage Below Normal
1357-19
Engine Cylinder #6 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1358-3
Engine Cylinder #7 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1358-4
Engine Cylinder #7 Knock Level : Voltage Below Normal
1358-19
Engine Cylinder #7 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1359-3
Engine Cylinder #8 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1359-4
Engine Cylinder #8 Knock Level : Voltage Below Normal
1359-19
Engine Cylinder #8 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1360-3
Engine Cylinder #9 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1360-4
Engine Cylinder #9 Knock Level : Voltage Below Normal
1360-19
Engine Cylinder #9 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1361-3
Engine Cylinder #10 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1361-4
Engine Cylinder #10 Knock Level : Voltage Below Normal
1361-19
Engine Cylinder #10 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1362-3
Engine Cylinder #11 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1362-4
Engine Cylinder #11 Knock Level : Voltage Below Normal
1362-19
Engine Cylinder #11 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1363-3
Engine Cylinder #12 Knock Level : Voltage Above Normal The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1363-4
Engine Cylinder #12 Knock Level : Voltage Below Normal
1363-19
Engine Cylinder #12 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1364-3
Engine Cylinder #13 Knock Level : Voltage Above Normal
3516 only The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1364-4
Engine Cylinder #13 Knock Level : Voltage Below Normal
3516 only
1364-19
Engine Cylinder #13 Knock Level : Data Error
3516 only The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1365-3
Engine Cylinder #14 Knock Level : Voltage Above Normal
3516 only The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1365-4
Engine Cylinder #14 Knock Level : Voltage Below Normal
3516 only
1365-19
Engine Cylinder #14 Knock Level : Data Error
3516 only The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated.
1366-3
Engine Cylinder #15 Knock Level : Voltage Above Normal
3516 only The Integrated Sensing Module (ISM) detects signal voltage that is not in the acceptable range. The code is logged.
The alarm output is activated.
1366-4
Engine Cylinder #15 Knock Level : Voltage Below Normal
3516 only
1366-19
Engine Cylinder #15 Knock Level : Data Error The level of detonation has exceeded the trip point. The code is logged.
The alarm output is activated. &
Parts plug JOHNSON:
0307551
0307551 PLUG,Gearcase
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML
0318544
0318544 PLUG,Gearcase lower
100ML79S, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 23
0329429
0334076
0334076 PLUG, Lower engine cover
J100STLCEM, J100STLEIE, J100STLEND, J100STLESB, J100STLETS, J100WTLEIB, J100WTLENE, J100WTLESM, J100WTLETD, J100WTLZ, J10ECCD, J10ECES, J10EEIR, J10EENA, J10EESC, J110MLCEM, J115JLEIE, J115JLEND, J115JLETS, J115MLESB, J120TLAEM, J120TLAIE, J120TLAND,