5030606 JOHNSON PLUG, Oil venturi


5030606 PLUG, Oil venturi JOHNSON BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF PLUG
5030606 PLUG, Oil venturi JOHNSON
Rating:
23

Buy PLUG, Oil venturi 5030606 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$513.50
 

22-12-2021

-: -
Haimer 50.306.06 Weldon Tool Holder, 6 mm Diameter, ZG 200 SK 50
Precision AT3 Tolerance Shank || Balanced to G2.5 at 22,000 RPM || All functional surfaces precision ground
Number on catalog scheme: 3
 

BRP JOHNSON entire parts catalog list:

BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
J25PL4SOC, J25TEL4SOC 2005
J25PL4SRS 2004
J30PL4SDR 2006
J30PL4SOC, J30TEL4SOC 2005
J30PL4SRS 2004
J30PL4SUA 2007
J30TEL4SDR 2006
J30TEL4SUA 2007
J60PL4SNF 2002
J70FLTLECS 1998
J70PL4SNF 2002

Information:


Illustration 1 g00840097
SchematicTest Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J3/P3 machine connector, and all other connectors in the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets should be completely inserted and coupled. The harness and wiring should be free of corrosion, abrasion, and pinch points. All connections and grounds should be tight and free of corrosion.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Resistance through the Solenoid
Turn the keyswitch to the OFF/RESET position.
Disconnect the push/pull solenoid for the variable pitch fan.
Measure the resistance between J160:1 (Push Solenoid) and J160:2 (Digital Return).
Measure the resistance between J160:4 (Pull Solenoid) and J160:3 (Digital Return).Expected Result:Resistance should be 25 5 Ohms.Results:
OK - The push/pull solenoid for the variable pitch fan has the correct resistance. Proceed to Test Step 3.
Not OK - The push/pull solenoid for the variable pitch fan is faulty.Repair: Install a new push/pull solenoid for the variable pitch fan.Verify that the repair eliminates the problem.STOPTest Step 3. Check the Status of the Manual Purge Switch on ET
Connect ET to the service tool connector.
Turn the keyswitch to the ON position.
Observe the status for "Engine Fan Manual Purge Switch" on ET while you operate the switch.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switch should be "On" when the switch is depressed. The status should read "Off" when the switch is released.Results:
OK - The manual purge switch is working properly. Proceed to Test Step 5.
Not OK - The ECM does not recognize the input from the manual purge switch. Proceed to Test Step 4.Test Step 4. Check the Manual Purge Switch
Turn the keyswitch to the OFF/RESET position.
Disconnect the J161/P161 manual purge switch connector.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the released position.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the depressed position.Expected Result:There should be no continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the released position. There should be continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the depressed position.Results:
OK - There is no continuity when the switch is in the released position. There is continuity when the switch is in the depressed position. Proceed to Test Step 5.
Not OK - There is a problem with the manual purge switch.Repair: Replace the manual purge switch with a new switch.Verify that the repair eliminates the problem.STOPTest Step 5. Check for Shorts in the Harness for the Variable Pitch Fan
Illustration 2 g00840099
The P1 ECM connector
Disconnect the J1/P1 ECM connector.
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between P1:22 (Manual Purge Switch) and chassis ground.
Measure the resistance between P1:28 (Pull Solenoid) and chassis ground.
Measure the resistance between P1:34 (Push Solenoid) and chassis ground.
Measure the resistance between P1:22 (Manual Purge Switch) and P1:29 (Digital Return).
Measure the resistance between P1:28 (Pull Solenoid) and P1:29 (Digital Return).
Measure the resistance between P1:34 (Push Solenoid) and P1:29 (Digital Return).
Measure the resistance between P1:22 (Manual Purge Switch) and P1:28 (Pull Solenoid).
Measure the resistance between P1:22 (Manual Purge Switch) and P1:34 (Push Solenoid).
Measure the resistance between P1:28 (Pull Solenoid) and P1:34 (Push Solenoid).Expected Result:The resistance for each measurement should be greater than 20,000 Ohms.Results:
OK - There are no shorts in the harness. Proceed to Test Step 6.
Not OK - There is a short between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.STOPTest Step 6. Check for Open Circuits in the Harness for the Variable Pitch Fan
Illustration 3 g00840099
J1/P1 breakout
Turn the keyswitch to the OFF/RESET position and disconnect the J1/P1 ECM connector.
Use a suitable piece of wire to short P1:22 (Manual Purge Switch) and P1:29 (Digital Return).
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between J161:B (Manual Purge Switch) and J161:C (Digital Return).
Use a suitable piece of wire to short P1:28 (Pull Solenoid) and P1:29 (Digital Return).
Measure the resistance between P160:4 (Pull Solenoid) and P160:3 (Digital Return).
Use a suitable piece of wire to short P1:34 (Push Solenoid) and P1:29 (Digital Return).
Measure the resistance between P160:1 (Push Solenoid) and P160:2 (Digital Return).
Remove all shorts and reconnect all connectors.Expected Result:The resistance should be less than 10 Ohms.Results:
OK - The wiring harness for the variable pitch fan is operating correctly. The ECM is not sending the correct signal to the push/pull solenoid for the variable pitch fan.Repair: Verify your results. Replace the ECM. Refer to Troubleshooting, "Replacing the ECM" before replacing the ECM.Verify that the repair eliminates the problem.STOP
Not OK - There is an open circuit between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOP


Parts plug JOHNSON:

5030521
PLUG
5030521 PLUG
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25R4SDS, BJ25TE4SDS, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM
5030523
 
5030523 PLUG
J70FLTLECS
5030524
 
5030524 PLUG
J70FLTLECS
5030522
 
5030522 PLUG
BJ115L4SRC, BJ140CX4SRS, BJ140PL4SRS, BJ40PL4SRS, BJ50PL4SRS, BJ60PL4SOA, BJ60PL4SRR, BJ70PL4SOA, BJ70PL4SRR, BJ90PL4SRC, J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD,
5031252
 
5031252 *PLUG
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5032660
 
5032660 *PLUG
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC
5032682
 
5032682 PLUG, Water
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
5032378
 
5032378 *PLUG
J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA