0387526 JOHNSON PROPELLER 11X9 SST


0387526 PROPELLER 11X9 SST JOHNSON 25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, J25RCSA, J35ECIG, J35ECND, J35ECSM PROPELLER
0387526 PROPELLER 11X9 SST JOHNSON
Rating:
58

Buy PROPELLER 11X9 SST 0387526 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 63
 

BRP JOHNSON entire parts catalog list:

25E77S, 25EL77H, 25EL77S, 25R77H, 25R77S, 25RL77H, 25RL77S 1977
25E78C, 25EL78C, 25R78C, 25RL78C 1978
25E79R, 25EL79R, 25R79R, 25RL79R 1979
35E76G, 35E76S, 35EL76G, 35EL76S, 35R76G, 35R76S, 35RL76G, 35RL76S 1976
35E77C, 35E77H, 35EL77C, 35EL77H, 35R77C, 35R77H, 35RL77C, 35RL77H 1977
35E78R, 35EL78R, 35R78R, 35RL78R 1978
35E79A, 35EL79A, 35R79A, 35RL79A 1979
J25RCSA, J25RLCSA, J25TECSA, J25TELCSA 1980
J35ECIG, J35ELCIG, J35RCIG, J35RLCIG 1981
J35ECND, J35ELCND, J35RCND, J35RLCND, J35TELCNB 1982
J35ECSM, J35ELCSM, J35RCSM, J35RLCSM 1980

Information:

The following background information is related to this procedure:Electronically controlled wastegateThe engine has a turbocharger with an electronically controlled wastegate. Typically, the wastegate is a mechanical valve that is used in the turbocharger in order to regulate the intake manifold pressure to a set value.The control system for the electronically controlled wastegate precisely regulates the intake manifold pressure by using a wastegate regulator to control the wastegate.The required intake manifold pressure is calculated by the software that is contained in the ECM. The ECM uses the wastegate regulator to control the wastegate in order to provide the precise value of intake manifold pressure. The solenoid in the wastegate regulator is controlled by a PWM signal.Fuel metering valve for the high-pressure fuel pump:The high-pressure fuel pump is equipped with a fuel metering valve. The fuel metering valve precisely controls the amount of fuel that enters the high-pressure fuel pump.The amount of fuel that is required is calculated by the software that is contained in the ECM. The solenoid in the suction control valve is controlled by a PWM signal from the ECM.
Illustration 1 g03732763
Schematic diagram for the solenoid valves
Illustration 2 g02351359
View of the pin locations on the P2 connector for the solenoid valves
(4) Wastegate regulator return
(15) Fuel metering valve supply
(60) Fuel metering valve return
Illustration 3 g03086696
View of the pin locations on the P1 connector
(1) Battery (+)
(28) Main relay control
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Check the fuses.
B. Thoroughly inspect the P2/J2 and P1/J1 ECM connectors and thoroughly inspect the connectors for the solenoid valves. Refer to Troubleshooting, "Electrical Connector - Inspect" for details.
C. Thoroughly inspect the 62-pin connector . Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
D. Perform a 30 N (6.7 lb) pull test on each of the wires that are associated with the solenoid valves.
Damaged wire or connector
Result: A damaged wire or damaged connector was found. A fuse is blown.
Repair: Repair the damaged wire or the damaged connector. Replace any blown fuses
Use the electronic service tool to clear all logged diagnostic codes. Verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly connected and/or inserted and the harness is free of corrosion, of abrasion or of pinch points.
Proceed to Test Step 2.
2. Check for Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Turn the keyswitch to the ON position.
D. Monitor the electronic service tool for active diagnostic codes and/or logged diagnostic codes.
Diagnostic codes
Result: A 1076-5 diagnostic code is active or recently logged.
Proceed to Test Step 3.
Result: A 1188-5 diagnostic code is active or recently logged.
Proceed to Test Step 4.
Result: A 1076-6 or 1188-6 diagnostic code is active or recently logged.
Proceed to Test Step 9.
Result: A 1076-2 diagnostic code is active or recently logged
Repair: An intermittent fault exists in the circuit for the fuel metering valve.
For intermittent faults, refer to Troubleshooting, "Electrical Connectors - Inspect".
3. Check the Power Supply to the ECM
A. Check that pin P1:1 is receiving the correct voltage. Refer to Troubleshooting, "Electrical Power Supply - Test".
Note: The power supply for the fuel pump metering valve is supplied through P1:1.
Power supply
Result: The power supply to P1:1 is faulty.
Repair: Perform any necessary repairs. Refer to Troubleshooting, "Electrical Power Supply - Test".
Result: The power supply to P1:1 is OK.
Proceed to Test Step 4.
4. Create a Short Circuit in the Harness at the Solenoid
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the suspect solenoid.
C. Fabricate a jumper wire that is 150 mm (6 inch) long.
D. Install the wire between the two pins on the harness connector for the suspect solenoid in order to create a short circuit.
E. Turn the keyswitch to the ON position. Check for active diagnostic codes on the electronic service tool.
F. Remove the jumper wire from the connector for the solenoid valve.
Diagnostic codes
Result: An -6 diagnostic code is active when the jumper is installed.
Repair: Temporarily connect a replacement for the suspect valve to the harness.
Turn the keyswitch to the ON position. Use the electronic service tool in order to check for active diagnostic codes. Wait at least 30 seconds in order for the codes to be displayed.
If the fault is eliminated, reconnect the suspect valve. If the fault returns, permanently install the replacement valve. Refer to Disassembly and Assembly for the correct procedure.
Result: An XXXX-5 diagnostic code is still active with the jumper installed.
Proceed to Test Step 5.
5. Create a Short Circuit at t


Parts propeller JOHNSON:

0386418
PROPELLER SHAFT
0386418 PROPELLER SHAFT
25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, J25RCSA, J35ECIG, J35ECND, J35ECSM, J35ECTS
0387525
 
0387525 PROPELLER 10-1/2X11 SST
25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, J25RCSA, J35ECIG, J35ECND, J35ECSM
0386637
 
0386637 PROPELLER 10-1/2X11 STD
25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30EECS, BJ30EEDE, BJ30EEEC, BJ30EEUD, BJ30ELSIA, BJ30ELSSR, HJ20CREDA, HJ25FPO, HJ25FPV, HJ25RLED
0386317
 
0386317 PROPELLER 11X9
25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC,
0389393
 
0389393 PROPELLER,9-1/4 x 9 sst
25E79R, 35E79A, J25ECIB, J25ECNE, J25ECRS, J25ECTD, J25RCSA, J35ECSM
0389321
 
0389321 PROPELLER,9-1/4 x 12 sst
25E79R, 35E79A, D25RWA, HJ25FPO, HJ25FPV, J25ECIB, J25ECNE, J25ECRS, J25ECTD, J25RCSA, J25RSA, J25RSLS, J25RWCDC, J25RWCOS, J25RWCRD, J25RWCUR, J25RWEIM, J25RWENB, J25RWEOS, J25RWERD, J25RWESA, J25RWETE, J25RWK, J28ELCDS, J28ELCDS, J28ESLCCR, J28ESLC
0388866
 
0388866 PROPELLER 10 X 13 SST
25E79R, 35E79A, J25RCSA, J35ECIG, J35ECSM
0390731
 
0390731 PROPELLER 10 X 17 SST
25E79R, 35E79A, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ25EECE, BJ25EEDM, BJ25EEED, BJ25EEUB, BJ25ELSIC, BJ25ELSSS, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEUD, BJ30EECS, BJ30EEDE, BJ30EEEC,
Back to top