0586075 JOHNSON RECTIFIER & REGULATOR


0586075 RECTIFIER & REGULATOR JOHNSON BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ90ELEDR, BJ90ELEUA, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLECM, J100WPLEEC, J100WPLSIF, J100WPLSSR, J100WQLECS, J105WELEEN, J105WELSIF, J105WELSSC, J105WPLSTM, J115GLSDE, J115G RECTIFIER
0586075 RECTIFIER & REGULATOR JOHNSON
Rating:
89

Buy RECTIFIER & REGULATOR 0586075 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$61.08

09-12-2024

CN: Geiyuar
Outboard Motor Rectifier, Metal Regulator 0586075 Replacement for Evinrudes 4 Cyl 6 Cyl 90Hp to 175 hps
Phefop OE Number: The referencing OE number of this voltage rectifier regulator are 0586075, 193‑6048, 0586048, molded and designed depend on the original data. || Fitment: The outboard motor rectifier is a replacement for Johnson Evinrudes 4 Cyl 6 Cyl 90‑175 hps 35Amp, please check before ordering. || Voltage Regulation: Regulates and stabilizes voltage output, protecting sensitive electrical components from damage, ensuring a consistent and reliables power supply. || High Safety: Ensuring voltage stability in the circuit system and protecting the equipment from problems such as overload, overvoltage and overheating to extend the life of the equipment || Ideal Replacement: Direct replacement installation, meets or exceeds OEM standards for the replacement of old and damaged one on original vehicles.
$155.50

10-02-2025

CN: KUNOANZ-US
193-6048 0586075 0586048 18-5829 Rectifier Regulator for Johnson & Evinrude 90 100 105 115 150 175 HP 2-Stroke Outboard 90hp 100hp 105hp 115hp 150hp 175hp Sierra:18-5830 586048,586075 1996-2006
KUNOANZ [Tips] : We will show more detailed information about the product on the details page below to ensure that we can help you to buy the correct replacement part || [Note] : In order to prevent purchasing the wrong unsuitable part, which could result in wasted time, you need to determine suitability by using the information on the engine nameplate || [Adaptation] : Part of the For Johnson&Evinrude :90hp 100hp 105hp 115hp 150hp 175hp, (1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006) BE90 E90 E100 E105 SE105 BE115 E115 BE150 E150 SE150 BE175 E175 BJ90 J90 K100 K105 BJ115 J115 RJ115 EJ150 J150 RJ150 SJ150 BJ175 J175 RJ175, 2-Stroke Engine || [OEM#] : Replacing part numbers For Evinrude & Johnson : 0586048 , 0586075 , 586048 , 586075 ;CDI Electronics : 193-6048 ;Sierra : 18-5829 , 18-5830 ;Mallory : 9-17204 , 9-17208 ;Engineered Marine Products : EMP300-03585 || [Quality] : Original level of quality and durability
$60.19

19-08-2024

CN: chenchenhebaihuo
Outboard For Motor Voltage Rectifier Regulator 0586075 Replacement Johnson Evinrude 90-175 Hp High Safety Power Supply
BTCEOS [OE NUMBER]: The referencing OE number are 0586075, 193‑6048, 0586048, molded and designed based on original data. || [FITMENT]: It is a replacement for Johnson Evinrude 90-175 Hp 35Amp, ensuring proper fitment for your outboard motor. || [VOLTAGE REGULATION]: Regulates and stabilizes voltage output to protect sensitive electrical components and ensure a consistent power supply. || [HIGH SAFETY]: Ensures voltage stability, protects equipment from overload, overvoltage, and overheating for an extended equipment lifespan. || [IDEAL REPLACEMENT]: Direct replacement installation that meets or exceeds OEM standards, for replacing old and damaged rectifiers.
Number on catalog scheme: 46
 

BRP JOHNSON entire parts catalog list:

BJ115ELEDR, BJ115GLEDR, BJ115SXEDR, HJ115SLEDR, J115ELEDR, J115GLEDR, J115SLEDR, J115SXEDR, SJ115ELEDR 1996
BJ115ELEUA, BJ115ELEUC, BJ115GLEUA, BJ115GLEUC, BJ115SXEUA, BJ115SXEUC, HJ115SLEUA, HJ115SLEUC, J115ELEUA, J115ELEUC, J115GLEUA, J115GLEUC, J115SLEUA, J115SLEUC, J115SXEUA, J115SXEUC 1997
BJ115GLECM, BJ115SXECM, HJ115SLECM, J115ELECM, J115GLECM, J115JTLECS, J115SLECM, J115SXECM 1998
BJ115PLEEM, BJ115PXEEM, J115JPLEEC, J115PLEEM, J115PXEEM, J115SPLEES 1999
BJ115PLSIE, BJ115VXSIC, J115JPLSIA, J115PLSIE, J115VLSIC, J115VXSIC, RJ115PLSIE, RJ115VLSIC, RJ115VXSIC 2001
BJ115PLSSB, BJ115PXSSB, BJ115VXSSS, J115JPLSSR, J115PLSSB, J115PXSSB, J115SPLSSC, J115VLSSS, J115VXSSS, RJ115PLSSB, RJ115PXSSB, RJ115VLSSB, RJ115VXSSS 2000
BJ90ELEDR, BJ90SLEDR, J90ELEDR, J90SLEDR, SJ90ELEDR 1996
BJ90ELEUA, BJ90ELEUC, BJ90SLEUA, BJ90SLEUC, BJ90SXEUA, BJ90SXEUC, J90ELEUA, J90ELEUC, J90SLEUA, J90SLEUC 1997
BJ90PLEEB, BJ90PXEEB, J90PLEEB, J90SPLEES 1999
BJ90PLSID, BJ90VLSIC, BJ90VXSIC, J90PLSID, J90VLSIC, RJ90PLSID, RJ90VLSIC 2001
BJ90PLSSE, BJ90PXSSE, BJ90VXSSS, J90PLSSE, J90SPLSSC, J90VLSSE, RJ90PLSSE, RJ90VLSSS 2000
BJ90SLECM, BJ90SXECM, J90ELECM, J90SLECM 1998
J100WPLEEC, J100WPXEEC 1999
J100WPLSIF, J100WPXSIF 2001
J100WPLSSR, J100WPXSSR 2000
J100WQLECS, J100WQXECS 1998
J105WELEEN, J105WELEES, J105WPLEEN, J105WPLEES, J105WPXEEN, J105WPXEES 1999
J105WELSIF, J105WPLSIF, J105WPXSIF 2001
J105WELSSC, J105WPLSSC, J105WPXSSC 2000
J105WPLSTM 2003
J115GLSDE 2006
J115GLSOB 2004,2005
J115GLSRC 2004
J115GLSTA, J115PLSTS, J115PXSTS 2003
J115PLSDA 2006
J115PLSNF, J115PXSNF, J115VLSNF 2002
J115PLSOR 2004,2005
J115PLSRC 2004
J115PXSDA 2006
J115PXSOR 2004,2005
J115PXSRM 2004
J115WPLSOC 2004,2005
J115WPLSRS 2004
J90GLSDE 2006
J90GLSOB 2004,2005
J90GLSRM 2004
J90GLSTA, J90PLSTC 2003
J90PLSDM 2006
J90PLSNF, J90VLSNF 2002
J90PLSOA 2004,2005
J90PLSRR 2004
J90PXSDR 2006
J90PXSOC 2004,2005
J90PXSRS 2004
SJ105WELV, SJ105WEXV, SJ105WRPLV, SJ105WRPXV 1998
SJ105WELV, SJ105WEXV, SJ105WRPLV, SJ105WRPXV 1998

Information:


Illustration 1 g00614755
System Schematic For Fuel Control Relay On ETR Systems
Note: For 3408 and 3412 engines, the AFCR shall be connected to SR terminal 87 instead of fuel solenoid, and provided with F16.
Illustration 2 g00614757
System Schematic For Fuel Control Relay On ETS Systems
The GSC uses the fuel control relay (FCR) to activate the fuel solenoid (FS). The FCR is located within the relay module. The fuel solenoid is located in the fuel system of the engine. There are two types of fuel system solenoids: energized to run (ETR) and energized to shutdown (ETS).
For ETR systems, the GSC activates the FCR which energizes the fuel solenoid to run the engine.
For ETS systems, the GSC activates the FCR which energizes the fuel solenoid to shutdown the engine. Note: Whenever the GSC activates or attempts to activate the FCR, "K7" is shown on the lower display. When the FCR is not activated, "K7" is not shown. Also, setpoint P01 selects the fuel solenoid type: 0 = ETR or 1 = ETS. The GSC treats this diagnostic code as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.The possible cause of a CID 447 FMI 12 fault is:
An open or shorted coil of the FCR. The system response to this fault is:
For ETR systems with the FCR activated - If a CID 447 fault occurs while the engine is running, then a CID 566 (unexpected shutdown) fault is declared and shutdown mode is functioning (the engine stops).
For ETR systems with the FCR not activated - If a CID 447 fault occurs, then the engine can not start or run.
For ETS systems with the FCR activated - If a CID 447 fault occurs, then the engine is able to run and start but the fuel solenoid will not shutdown the engine.
For ETS systems with the FCR not activated - If a CID 447 fault occurs, then the engine is able to run and start but the fuel solenoid will not shutdown the engine. Note: On 3500 engines equipped with an electronic governor, the status of the FCR has no effect on starting or running the engine. The GSC treats a CID 447 fault as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed and the ECS switch is in any position except the OFF/RESET position. Clear the fault from the fault log after troubleshooting is complete. This troubleshooting procedure is for an active or inactive CID 447 fault.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 447 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 447 FMI 12 is showing as a active fault or an inactive fault. Results:
No - A CID 447 FMI 12 has not occurred (NOT active and NOT inactive). STOP.
Yes - A CID 447 FMI 12 is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module Replace".
Check the cable that attaches the relay module to the GSC. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK - Reassemble the relay module to the GSC. Proceed to 3.
NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.
Perform a functional check for the ASR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-15 of the relay module.
At the relay module, measure the resistance from RM-15 to RM-4. Resistance should be greater than 5000 ohms.
Turn the ECS to the START position. Make sure that "K7" is showing in the lower display.
At the relay module, measure the resistance from RM-15 to RM-4. Resistance should be less than 5 ohms. Expected Result: For 3c, the resistance should be greater than 5000 ohms. For 3e, the resistance should be less than 5 ohms.Results:
OK - It is likely that a temporary bad electrical connection existed and this troubleshooting procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK - Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts rectifier JOHNSON:

0585001
 
0585001 RECTIFIER & LEAD
BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ50BEEDS, BJ50DTLEDC, BJ50DTLEUR, BJ50EEER, BJ50ELSIF, BJ50ELSSA, BJ50ESECC, BJ50RLEUC, BJ60ELEDR, BJ60ELEUA, BJ60TLECM, BJ70ELECB, BJ70ELEDA, BJ70ELEUM, BJ70PLEEE, BJ70PLSIS, BJ70PLSSD,
Back to top