0340418 RETAINER, Upper mount JOHNSON
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ90ELEDR, BJ90ELEUA, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLECM, J100
RETAINER
Price: query
Rating:
Compatible models:
BJ115ELEDR
BJ115ELEUA
BJ115GLECM
BJ115PLEEM
BJ115PLSIE
BJ115PLSSB
BJ150ELECD
BJ150ELEDB
BJ150ELEUC
BJ175EXECD
BJ175EXEDB
BJ175EXEUC
BJ175PLEES
BJ175PLSIF
BJ175PLSSC
BJ90ELEDR
BJ90ELEUA
BJ90PLEEB
BJ90PLSID
BJ90PLSSE
BJ90SLECM
J100WPLEEC
J100WPLSIF
J100WPLSSR
J100WQLECS
J105WELEEN
J105WELSIF
J105WELSSC
J105WPLSTM
J105WRLEES
J105WRLSIF
J105WRLSSC
J115ELEOC
J115FSLECS
J115GLSDE
J115GLSOB
J115GLSRC
J115GLSTA
J115PLSDA
J115PLSNF
J115PLSOR
J115PLSRC
J115PXSDA
J115PXSOR
J115PXSRM
J115WPLSOC
J115WPLSRS
J150CXEES
J150CXSDE
J150CXSNF
J150CXSOB
J150CXSRM
J150CXSSC
J150CXSTA
J150ELARA
J150ELEOM
J150FCXECR
J150GLSDE
J150GLSOB
J150GLSRM
J150GLSTA
J150GLSTF
J150ICXEUC
J150JPLSIF
J150MLSOR
J150MLSRC
J150MLSTS
J150PLSDD
J150PLSOE
J150PLSRB
J150PLSTF
J150PXSDD
J150PXSOE
J150PXSRB
J150WPLEES
J150WPLSIF
J150WPLSSC
J150WTLEOR
J150WTLERC
J175CXSDE
J175CXSNF
J175CXSOB
J175CXSRM
J175CXSTA
J175EXARC
J175EXEOM
J175FCXECS
J175GLSDE
J175GLSOB
J175GLSRM
J175GLSTA
J175GLSTF
J175MXSOR
J175MXSRC
J175MXSTS
J175PLSDD
J175PLSOE
J175PLSRB
J175PLSTF
J175PXSDD
J175PXSOE
J175PXSRB
J90ELEOC
J90FSLECS
J90GLSDE
J90GLSOB
J90GLSRM
J90GLSTA
J90PLSDM
J90PLSNF
J90PLSOA
J90PLSRR
J90PXSDR
J90PXSOC
J90PXSRS
SJ105RWLH
SJ105RWLP
SJ105WELV
SJ150WTPLB
SJ150WTPLT
SJ150WTPLY
JOHNSON
BRP JOHNSON entire parts catalog list:
- CYLINDER & CRANKCASE » 0340418
BJ115GLECM, BJ115SXECM, HJ115SLECM, J115ELECM, J115GLECM, J115JTLECS, J115SLECM, J115SXECM 1998
BJ115PLEEM, BJ115PXEEM, J115JPLEEC, J115PLEEM, J115PXEEM, J115SPLEES 1999
BJ115PLSIE, BJ115VXSIC, J115JPLSIA, J115PLSIE, J115VLSIC, J115VXSIC, RJ115PLSIE, RJ115VLSIC, RJ115VXSIC 2001
BJ115PLSSB, BJ115PXSSB, BJ115VXSSS, J115JPLSSR, J115PLSSB, J115PXSSB, J115SPLSSC, J115VLSSS, J115VXSSS, RJ115PLSSB, RJ115PXSSB, RJ115VLSSB, RJ115VXSSS 2000
BJ150ELECD, BJ150EXECD, BJ150GLECD, BJ150NXECD, J150ELECD, J150EXECD, J150GLECD, J150JLECD, J150NXECD, J150SLECD 1998
BJ150ELEDB, BJ150EXEDB, BJ150GLEDB, BJ150NXEDB, J150ELEDB, J150EXEDB, J150GLEDB, J150JLEDB, J150NXEDB, J150SLEDB, SJ150ELEDB 1996
BJ150ELEUC, BJ150ELEUE, BJ150EXEUC, BJ150EXEUE, BJ150GLEUC, BJ150GLEUE, BJ150NXEUC, BJ150NXEUE, J150ELEUC, J150ELEUE, J150EXEUC, J150EXEUE, J150GLEUC, J150GLEUE, J150JLEUC, J150JLEUE, J150NXEUC, J150NXEUE, J150SLEUC, J150SLEUE 1997
BJ175EXECD, BJ175GLECD, BJ175NXECD, J175EXECD, J175GLECD, J175NXECD, J175SLECD 1998
BJ175EXEDB, BJ175GLEDB, BJ175NXEDB, J175EXEDB, J175GLEDB, J175NXEDB, J175SLEDB 1996
BJ175EXEUC, BJ175EXEUE, BJ175GLEUC, BJ175GLEUE, BJ175NXEUC, BJ175NXEUE, J175EXEUC, J175EXEUE, J175GLEUC, J175GLEUE, J175NXEUC, J175NXEUE, J175SLEUC, J175SLEUE 1997
BJ175PLEES, BJ175PXEES, J175CXEES, J175PLEES, J175PXEES, J175SPLEES 1999
BJ175PLSIF, BJ175VXSIF, J175PLSIF, J175VCXSIF, J175VLSIF, J175VXSIF, RJ175CXSIF, RJ175PLSIF, RJ175VXSIF 2001
BJ175PLSSC, BJ175PXSSC, BJ175VXSSS, J175CXSSS, J175PLSSC, J175PXSSC, J175SPLSSC, J175VCXSSS, J175VLSSS, J175VXSSS, RJ175CXSSS, RJ175PLSSC, RJ175VXSSS 2000
BJ90ELEDR, BJ90SLEDR, J90ELEDR, J90SLEDR, SJ90ELEDR 1996
BJ90ELEUA, BJ90ELEUC, BJ90SLEUA, BJ90SLEUC, BJ90SXEUA, BJ90SXEUC, J90ELEUA, J90ELEUC, J90SLEUA, J90SLEUC 1997
BJ90PLEEB, BJ90PXEEB, J90PLEEB, J90SPLEES 1999
BJ90PLSID, BJ90VLSIC, BJ90VXSIC, J90PLSID, J90VLSIC, RJ90PLSID, RJ90VLSIC 2001
BJ90PLSSE, BJ90PXSSE, BJ90VXSSS, J90PLSSE, J90SPLSSC, J90VLSSE, RJ90PLSSE, RJ90VLSSS 2000
BJ90SLECM, BJ90SXECM, J90ELECM, J90SLECM 1998
J100WPLEEC, J100WPXEEC 1999
J100WPLSIF, J100WPXSIF 2001
J100WPLSSR, J100WPXSSR 2000
J100WQLECS, J100WQXECS 1998
J105WELEEN, J105WELEES, J105WPLEEN, J105WPLEES, J105WPXEEN, J105WPXEES 1999
J105WELSIF, J105WPLSIF, J105WPXSIF 2001
J105WELSSC, J105WPLSSC, J105WPXSSC 2000
J105WPLSTM 2003
J105WRLEES, J105WRYEES 1999
J105WRLSIF, J105WRYSIF 2001
J105WRLSSC, J105WRYSSC 2000
J115ELEOC, J115GLEOC, J115SLEOC, J115SXEOC 1995
J115FSLECS, J115FSXECS, J115FTLECS 1998
J115GLSDE 2006
J115GLSOB 2004,2005
J115GLSRC 2004
J115GLSTA, J115PLSTS, J115PXSTS 2003
J115PLSDA 2006
J115PLSNF, J115PXSNF, J115VLSNF 2002
J115PLSOR 2004,2005
J115PLSRC 2004
J115PXSDA 2006
J115PXSOR 2004,2005
J115PXSRM 2004
J115WPLSOC 2004,2005
J115WPLSRS 2004
J150CXEES, J150JPLEES, J150PLEES, J150PXEES, J150SPLEES 1999
J150CXSDE 2006
J150CXSNF, J150PLSNF, J150PXSNF, J150VLSNF 2002
J150CXSOB 2004,2005
J150CXSRM 2004
J150CXSSC, J150JPLSSC, J150MXSSD, J150PLSSC, J150PXSSC, J150SPLSSC, J150VCSSS, J150VLSSS, J150VXSSS, RJ150CXSSC, RJ150PLSSC, RJ150PXSSC, RJ150VCSSS, RJ150VLSSS, RJ150VXSSS 2000
J150CXSTA 2003
J150ELARA, J150ELARV, J150ELERA, J150ELERV, J150EXARC, J150EXARV, J150EXERA, J150EXERV, J150GLERA, J150GLERV, J150JLERA, J150JLERV, J150NXARC, J150NXARV, J150NXERA, J150NXERV 1994
J150ELEOM, J150EXEOM, J150GLEOM, J150JLEOM, J150NXEOM, J150SLEOM, VJ150HLEOS 1995
J150FCXECR, J150FSLECR, J150FSXECR, J150ILECR 1998
J150GLSDE 2006
J150GLSOB 2004,2005
J150GLSRM 2004
J150GLSTA, J150PLSTM, J150PXSTM 2003
J150GLSTF 2003
J150ICXEUC, J150ILEUC, J150IXEUC, J150PLEUC 1997
J150JPLSIF, J150PLSIF, J150VCXSIF, J150VLSIF, J150VXSIF, RJ150PLSIF, RJ150VCSIF, RJ150VLSIF, RJ150VXSIF 2001
J150MLSOR, J150MXSOR 2004,2005
J150MLSRC, J150MXSRC 2004
J150MLSTS, J150MXSTS 2003
J150PLSDD 2006
J150PLSOE 2004,2005
J150PLSRB 2004
J150PLSTF 2003
J150PXSDD 2006
J150PXSOE 2004,2005
J150PXSRB 2004
J150WPLEES 1999
J150WPLSIF 2001
J150WPLSSC 2000
J150WTLEOR, J150WTXEOR 1995
J150WTLERC, J150WTLERV, J150WTXERC, J150WTXERV 1994
J175CXSDE 2006
J175CXSNF, J175PLSNF, J175PXSNF, J175VLSNF 2002
J175CXSOB 2004,2005
J175CXSRM 2004
J175CXSTA 2003
J175EXARC, J175EXARV, J175EXERA, J175EXERV, J175GLERA, J175NXARC, J175NXARV, J175NXERA, J175NXERV, J175SLERA 1994
J175EXEOM, J175GLEOM, J175NXEOM, J175SLEOM 1995
J175FCXECS, J175FSLECS, J175FSXECS, J175FTLECS 1998
J175GLSDE 2006
J175GLSOB 2004,2005
J175GLSRM 2004
J175GLSTA, J175PLSTM, J175PXSTM 2003
J175GLSTF 2003
J175MXSOR 2004,2005
J175MXSRC 2004
J175MXSTS 2003
J175PLSDD 2006
J175PLSOE 2004,2005
J175PLSRB 2004
J175PLSTF 2003
J175PXSDD 2006
J175PXSOE 2004,2005
J175PXSRB 2004
J90ELEOC, J90EXEOC, J90SLEOC 1995
J90FSLECS, J90FTLECS 1998
J90GLSDE 2006
J90GLSOB 2004,2005
J90GLSRM 2004
J90GLSTA, J90PLSTC 2003
J90PLSDM 2006
J90PLSNF, J90VLSNF 2002
J90PLSOA 2004,2005
J90PLSRR 2004
J90PXSDR 2006
J90PXSOC 2004,2005
J90PXSRS 2004
Information:
Troubleshooting the electronic ride/fan control system requires additional information from the machine Service Manual. The Electrical System Schematic and the Operation & Maintenance Manual are required support material.As a guide, a typical schematic for the ride/fan control system is at the end of this manual. For a complete schematic, see the Electrical System Schematic in the machine Service Manual.When the troubleshooting procedure instructs to REPAIR THE HARNESS, use the Electrical System Schematic in the machine Service Manual to trace the circuit. Perform continuity checks at connectors to locate harness failures. At component connectors, always check the ground circuit. Less than 5 ohms of resistance is required between the connector ground contacts and frame ground. Excessive ground resistance, greater than 5 ohms, can cause incorrect diagnosing of problems.During troubleshooting, inspect all component and harness connections before any component is replaced. If these connections are not clean and tight they can cause electrical problems, either permanent or intermittent (come and go). Make sure the connections are tight before other tests are made.Failure of an electrical component can cause or be caused by the failure of one or more other components. Always attempt to find and correct the cause of electrical system failure before replacing a component.
Caterpillar Digital MultimeterUse the 6V7070 Digital Multimeter or equivalent for making continuity checks, resistance measurements or voltage measurements. The optional 8T3224 Needle Tip Group for the 6V7070, is useful during troubleshooting. For instruction on use of the 6V7070, see Special Instruction SEHS7734. Continuity testers (such as 8T0500), or voltage testers (such as 5P7277) are not recommended for use on present-day Caterpillar electrical circuits, except for harness tests.The service connector provides access to the service and clear inputs. Connector contact 1 is the service input and contact 2 is the clear input. The service connector is located near the control. For a more exact service connector location and connector requirements, see the Electrical System Schematic in the machine Service Manual.Diagnostic Summary
Various diagnostic functions require the grounding and/or opening of the service and clear contacts at the service connector. During troubleshooting, it is necessary for the service person to make the proper electrical connections between the contacts of the service connector. These electrical connections may be made with two jumpers. Also see the topic Service Box in the Testing And Adjusting section. The same diagnostic information is shown on the computerized monitoring system (CMS). Troubleshooting of ride/fan control system faults can be done through CMS. When using CMS for troubleshooting, all faults associated with the ride/fan control have a MID of 73. For more information, see service manual SENR5247 "Computerized Monitoring System (CMS) With VFD Circular Gauges".Service Box
Service BoxA service box is helpful for the service person to make the proper electrical connections at the service connector during troubleshooting. A service box and wiring diagram is shown in the Service Box illustration. Two connectors are wired in parallel so that the service box is usable on the different types of machine harnesses. To fabricate the service box, the required components are:(1) Clear switch: one 8D2676 Switch.(2) Scroll switch: one 8D2676 Switch.(3) Mode select switch: one 7N8009 Switch.(4) Sure-Seal® connector: one 7N8205 Plug, two 7N7779 Sockets, two 7N7780 Pins.(5) DT® connector: one 3E3373 Plug, four 8T8730 Sockets.(6) Enclosure: locally obtained.(7) Eighteen or sixteen gauge wire: locally obtained.(8) Grommet: locally obtained.Actuating the mode switch scrolls through the two display modes. Actuating the scroll switch scrolls the display with the control in service mode. Actuating the clear switch clears the fault being continuously shown (on hold) when in service mode. instead of having to make a service box, the 9U6665 Service Tool is available. The service tool works similar to the service box.Changing Modes
Ride/Fan Control Display
(1) Readout. (2) Fault present indicator (red). (3) Service mode indicator (yellow). (4) Power indicator (green).The ride/fan control has two display modes. The different modes are identified by the mode number which is shown on readout (1). The display modes are: * Mode 0 - Normal Mode* Mode 1 - Service ModeProcedure
1. Turn key start switch ON. Wait for the Self Test to finish; approximately two seconds.2. At the same time, ground the service and clear contacts of the service connector. This causes the mode numbers to scroll on readout (1). Each time "-0-." is shown, the scrolling stops. The service and clear contacts must be opened from ground, then closed to ground, to scroll the modes again.3. When the desired mode number is shown on readout (1), remove ground from (open) the service and clear contacts.Detected Faults
Initial Troubleshooting Procedure
Ride/Fan Control Display
(1) Readout. (2) Fault present indicator (red). (3) Service mode indicator (yellow). (4) Power indicator (green).When the control detects a fault, the corresponding CID and FMI are shown on readout (1) of the display. Service mode (mode 1) allows for troubleshooting and clearing of each detected fault. For detailed information, see the topic Service Mode (Mode 1) in the Systems Operation section.Use the following procedure for troubleshooting a detected fault. When a fault is detected, the readout will show the fault.1. Enter service mode (mode 1).2. The CID and FMI for the first fault are shown on readout (1) and the fault is on-hold at this time. The display shows "---.", when no fault has occurred.3. To see all detected faults, scroll the faults. To do so, ground the service contact of the service connector.4. Place the desired fault on-hold (stop the scrolling). To do so, remove ground from the service contact of the service connector when the desired fault is shown.5. Observe fault present indicator (2):* If fault present indicator (2) is ON, the fault shown is currently present.* If fault present indicator (2) is OFF, the fault shown is not present at this time. The fault has occurred and then went away, sometime in the past (intermittent).6. To troubleshoot the fault, go to the procedure with that CID and FMI. A general method to locate intermittent faults is to wiggle the related wiring while a helper watches the status of fault present
Caterpillar Digital MultimeterUse the 6V7070 Digital Multimeter or equivalent for making continuity checks, resistance measurements or voltage measurements. The optional 8T3224 Needle Tip Group for the 6V7070, is useful during troubleshooting. For instruction on use of the 6V7070, see Special Instruction SEHS7734. Continuity testers (such as 8T0500), or voltage testers (such as 5P7277) are not recommended for use on present-day Caterpillar electrical circuits, except for harness tests.The service connector provides access to the service and clear inputs. Connector contact 1 is the service input and contact 2 is the clear input. The service connector is located near the control. For a more exact service connector location and connector requirements, see the Electrical System Schematic in the machine Service Manual.Diagnostic Summary
Various diagnostic functions require the grounding and/or opening of the service and clear contacts at the service connector. During troubleshooting, it is necessary for the service person to make the proper electrical connections between the contacts of the service connector. These electrical connections may be made with two jumpers. Also see the topic Service Box in the Testing And Adjusting section. The same diagnostic information is shown on the computerized monitoring system (CMS). Troubleshooting of ride/fan control system faults can be done through CMS. When using CMS for troubleshooting, all faults associated with the ride/fan control have a MID of 73. For more information, see service manual SENR5247 "Computerized Monitoring System (CMS) With VFD Circular Gauges".Service Box
Service BoxA service box is helpful for the service person to make the proper electrical connections at the service connector during troubleshooting. A service box and wiring diagram is shown in the Service Box illustration. Two connectors are wired in parallel so that the service box is usable on the different types of machine harnesses. To fabricate the service box, the required components are:(1) Clear switch: one 8D2676 Switch.(2) Scroll switch: one 8D2676 Switch.(3) Mode select switch: one 7N8009 Switch.(4) Sure-Seal® connector: one 7N8205 Plug, two 7N7779 Sockets, two 7N7780 Pins.(5) DT® connector: one 3E3373 Plug, four 8T8730 Sockets.(6) Enclosure: locally obtained.(7) Eighteen or sixteen gauge wire: locally obtained.(8) Grommet: locally obtained.Actuating the mode switch scrolls through the two display modes. Actuating the scroll switch scrolls the display with the control in service mode. Actuating the clear switch clears the fault being continuously shown (on hold) when in service mode. instead of having to make a service box, the 9U6665 Service Tool is available. The service tool works similar to the service box.Changing Modes
Ride/Fan Control Display
(1) Readout. (2) Fault present indicator (red). (3) Service mode indicator (yellow). (4) Power indicator (green).The ride/fan control has two display modes. The different modes are identified by the mode number which is shown on readout (1). The display modes are: * Mode 0 - Normal Mode* Mode 1 - Service ModeProcedure
1. Turn key start switch ON. Wait for the Self Test to finish; approximately two seconds.2. At the same time, ground the service and clear contacts of the service connector. This causes the mode numbers to scroll on readout (1). Each time "-0-." is shown, the scrolling stops. The service and clear contacts must be opened from ground, then closed to ground, to scroll the modes again.3. When the desired mode number is shown on readout (1), remove ground from (open) the service and clear contacts.Detected Faults
Initial Troubleshooting Procedure
Ride/Fan Control Display
(1) Readout. (2) Fault present indicator (red). (3) Service mode indicator (yellow). (4) Power indicator (green).When the control detects a fault, the corresponding CID and FMI are shown on readout (1) of the display. Service mode (mode 1) allows for troubleshooting and clearing of each detected fault. For detailed information, see the topic Service Mode (Mode 1) in the Systems Operation section.Use the following procedure for troubleshooting a detected fault. When a fault is detected, the readout will show the fault.1. Enter service mode (mode 1).2. The CID and FMI for the first fault are shown on readout (1) and the fault is on-hold at this time. The display shows "---.", when no fault has occurred.3. To see all detected faults, scroll the faults. To do so, ground the service contact of the service connector.4. Place the desired fault on-hold (stop the scrolling). To do so, remove ground from the service contact of the service connector when the desired fault is shown.5. Observe fault present indicator (2):* If fault present indicator (2) is ON, the fault shown is currently present.* If fault present indicator (2) is OFF, the fault shown is not present at this time. The fault has occurred and then went away, sometime in the past (intermittent).6. To troubleshoot the fault, go to the procedure with that CID and FMI. A general method to locate intermittent faults is to wiggle the related wiring while a helper watches the status of fault present
Parts retainer JOHNSON:
0307861
0307861 RETAINER, Disc valve spring
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78
0307857
0307857 RETAINER, Valve
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78
0318165
0318165 RETAINER, Link to lever and handle
10E74G, 15E74G, 40E73D, 40E74S, 40E75C, 40E76A, 50ES73R, 50ES74M, 50ES75B, AM55RSLD, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSI
0387041
0387041 RETAINER & NEEDLE SET
100ML79S, 115ML79R, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ML79R, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130
0912233
0912233 RETAINER, Pivot shaft seal
BJ115PLSIE, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC
0513787
0513787 RETAINER, Limit switch
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF
0335814
0335814 RETAINER, Trail lock spring
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF
0340201
0340201 RETAINER, Fitting
BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ135PLSIF, BJ150ELECD, BJ150ELEUC, BJ175EXECD, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR