0395243 JOHNSON RETAINER & LINK ASSEMBLY


0395243 RETAINER & LINK ASSEMBLY JOHNSON J10ECCD, J10ECDB, J10ECES, J10ECOM, J10ECUE, J10EEIR, J10EENA, J10EESC, J15ECCS, J15ECDE, J15ECEC, J15ECOB, J15ECUD, J15EEIA, J15EENM, J15EESR, VJ14RCCS, VJ14RCCS, VJ14RCEC, VJ14RCEC RETAINER
0395243 RETAINER & LINK ASSEMBLY JOHNSON
Rating:
8

Buy RETAINER & LINK ASSEMBLY 0395243 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$36.99
 

12-09-2017
1.00[0.45] pounds
OMC: OMC
0389205 0391618 0395243 Retainer and Link Assembly Evinrude Johnson 9.9 15 hp 1979 1980
OMC||0389205||1979-80||9.9-15
Number on catalog scheme: 4
 

BRP JOHNSON entire parts catalog list:

J10ECCD, J10ELCCD, J10RCCD, J10RLCCD, J10SELCCD 1988
J10ECDB, J10ELCDB, J10RCDB, J10RLCDB, J10SELCDB 1986
J10ECES, J10ELCES, J10RCES, J10RLCES, J10SELCES, TJ10ELCES, TJ10RLCES 1989
J10ECOM, J10ELCOM, J10RCOM, J10RLCOM, J10SELCOM 1985
J10ECUE, J10ELCUE, J10RCUE, J10RLCUE, J10SELCUE 1987
J10EEIR, J10ELEIR, J10REIR, J10RELEIR, J10RLEIR, J10SELEIR, TJ10RELEIR 1991
J10EENA, J10ELENA, J10RELENA, J10RENA, J10RLENA, J10SELENA, TJ10RELENA 1992
J10EESC, J10ELESC, J10RELESC, J10RESC, J10RLESC, J10SELESC, TJ10ELESC, TJ10RELESC, TJ10RLESC 1990
J15ECCS, J15ELCCS, J15RCCS, J15RLCCS 1988
J15ECDE, J15ELCDE, J15RCDE, J15RLCDE 1986
J15ECEC, J15ELCEC, J15RCEC, J15RLCEC, TJ15RLCEC 1989
J15ECOB, J15ELCOB, J15RCOB, J15RLCOB 1985
J15ECUD, J15ELCUD, J15RCUD, J15RLCUD 1987
J15EEIA, J15ELEIA, J15REIA, J15RELEIA, J15RLEIA 1991
J15EENM, J15ELENM, J15RELENM, J15RENM, J15RLENM 1992
J15EESR, J15ELESR, J15RELESR, J15RESR, J15RLESR 1990
VJ14RCCS 1988
VJ14RCCS 1988
VJ14RCEC 1989
VJ14RCEC 1989

Information:


Table 1
Diagnostic Codes Table
J1939 Code and Description Conditions which Generate this Code System Response
632-5 Engine Fuel Shutoff Valve #1 : Current Below Normal The Electronic Control Module (ECM) detects a low current in the circuit for the GSOV for 2 seconds.
The output driver must be off for 5 seconds in order for this code to become active. The code is logged.
The amber warning lamp is illuminated.
The service tool displays "Error Indicator" on the status screen for this parameter.
632-6 Engine Fuel Shutoff Valve #1 : Current Above Normal While the output driver is on for 5 seconds, the ECM detected a high current in the circuit for the GSOV for one second. The code is logged.
The amber warning lamp is illuminated.
The service tool displays "Error Indicator" on the status screen for this parameter.
The output driver automatically resets and the output driver continues to try to activate the circuit component.
632-7 Engine Fuel Shutoff Valve #1 : Not Responding Properly The Engine Control Switch (ECS) is placed in the STOP position. The ECM has shut off the fuel to the engine, but the engine rpm remains above the crank terminate speed. The engine speed exceeded the crank terminate speed for a period that exceeds the "Engine Speed Drop Time". The code is logged.
The red stop lamp is illuminated.
The power to the GSOV remains in the de-energized state and the ECM removes ignition power from the engine. The ECM contains the logic and the outputs for control of starting the engine and stopping the engine. Some of the logic for starting the engine and for stopping the engine is customer programmable. The logic responds to inputs from the following components: engine control, emergency stop switch, remote start switch, data link and other inputs.The ECM outputs a signal in order to control the solenoid for the GSOV. To enable gas flow to the engine, the GSOV must be energized.The most likely cause of a diagnostic code is a poor electrical connection or a problem in a wiring harness. The next likely cause may be a problem with the solenoid. The least likely cause is a problem with the ECM.When the 632-7 Engine Fuel Shutoff Valve #1 : Failure occurs, the ECM assumes that the GSOV did not close. The ECM terminates the ignition. If the GSOV does not respond to the ECM command, unburned gas will remain in the air inlet and exhaust system.Note: Ensure that the unburned gas is purged from the exhaust before restarting the engine. Failure to purge the unburned gas from the engine may result in an explosion in the exhaust piping.The following information describes the systems operation when the GSOV is controlled by the ECM:The ECM sends an output signal to the solenoid for the GSOV that controls the operation of the GSOV. This output is energize-to-run. During the crank cycle, when the engine speed exceeds 50 rpm, the ECM provides a voltage of +Battery to the output for the GSOV. The solenoid becomes energized. As the valve opens, fuel begins to flow to the engine. The ECM removes the voltage from this output in order to stop the engine. The solenoid for the GSOV becomes de-energized. The fuel flow to the engine is stopped.
Illustration 1 g02402157
Schematic of the circuit for the GSOV
Note: Due to certain regulations for this application, the harness for the GSOV contains an unused shield circuit.Test Step 1. Inspect the Electrical Connectors and the Wiring
Remove the electrical power from the engine.
Illustration 2 g02402236
Location of the connectors at the ECM control box (top engine view)
(1) Engine harness connector (for non-incendive electrical devices)
(2) J2/P2 ECM connectors for the GSOV
Illustration 3 g02402319
Location of the components that are for control of the GSOV (typical location)
(3) Solenoid for the GSOV
(4) Gas shutoff valve
Thoroughly inspect connectors (1) and (2). Also, inspect the connectors for solenoid (3). Refer to Testing and Adjusting, "Electrical Connectors - Inspect" for details.
Illustration 4 g02402333
Terminal locations at the P2 ECM connector that are associated with the GSOV
(P21-5) Gas shutoff valve
(P2-52) Return
Illustration 5 g01415822
Terminal locations at the connector for the GSOV
(Terminal A) Gas shutoff valve
(Terminal B) Return
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit for the GSOV.
Check the hex head bolt for each of the ECM connectors for the proper torque. Refer to Testing and Adjusting, "Electrical Connectors - Inspect" for the correct torque values.
Check the wiring harnesses for abrasion, for corrosion and for pinch points. Expected Result:All connectors, pins, and sockets are coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and wiring appear to be OK. Proceed to Test Step 2.
Not OK - There is a problem in the wiring harness.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are coupled. Verify that the problem is resolved.STOPTest Step 2. Check for Active Diagnostic Codes
Ensure that the electrical power has been removed from the engine.
Connect Cat ET to the service tool connector. Refer to Troubleshooting, "Electronic Service Tools".
Restore the electrical power to the engine. Set the engine control to STOP. Note: The 632-5 Engine Fuel Shutoff Valve #1 : Current Below Normal can only be detected when the output for the start command is off. The output is normally off when the engine control is set to STOP and the engine speed is zero rpm.
Monitor


Parts retainer JOHNSON:

0307861
 
0307861 RETAINER, Disc valve spring
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78
0307857
 
0307857 RETAINER, Valve
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78
0315232
 
0315232 RETAINER, Needle valve
100ESL71A, 10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 115ESL69E, 115ESL70D, 125ESL71C, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69
0316487
 
0316487 RETAINER, Dist. lead
100ESL71A, 100ESL72R, 115ESL70D, 125ESL71C, 125ESL72R, 85ESL70B, 85ESL71A, 85ESL72R, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ20SEECB, BJ20SEEDA, BJ20SEEUM, BJ20SRECB, B
0321077
 
0321077 RETAINER,Fuse holder
100ML79S, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 50R79C, 55E78S, 55E79C, 70EL79R, 75ELR79R, 85ETLR78C, 85ML79R, BJ250CXECB, BJ250CXEDA, BJ
0322549
 
0322549 RETAINER,4 terminal
100ML79S, 10E77A, 10E78M, 10EL79B, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL79C, 15E77M, 15E78B, 15E79E, 175TL79R, 200TL79A, 235TL70A, 25E77S, 25E78C, 25E79R, 35E77C, 35E78R, 35E79A, 4R77B, 4R78E, 4R79D, 50R79C, 55E78S, 55E79C, 6R77M, 6R78B, 6R7
0511618
 
0511618 RETAINER, Connector
100ML79S, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 70EL79R, 75ELR79R, 85ETLR78C, 85ML79R, CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM, J100MLCSC, J100STLCCA, J100STLCEM, J100WMLCOC, J100WMLCRS, J10
0323654
 
0323654 RETAINER, Starter spring
10EL79B, 15E79E, J10ECCD, J10ECDB, J10ECES, J10ECOM, J10ECSE, J10ECUE, J10EEIR, J10EENA, J10EESC, J10ELCID, J10ELCNS, J10ELCRA, J10ELCTC, J15ECCS, J15ECDE, J15ECEC, J15ECIS, J15ECNC, J15ECOB, J15ECRM, J15ECSD, J15ECTR, J15ECUD, J15EEIA, J15EENM, J15E
Back to top