0984468 RUBBER MOUNT ASSY., Upper JOHNSON
J250CXARC, J250CXATF, J250CXEIE, J250CXEND, J250CXEOR, J275CXCCA, J300CXCCA, J300CXCEM, J300CXEIE, J300CXEND, J300CXEOR, J300CXERC, J300CXESB, J300CXETF
RUBBER
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- MIDSECTION » 0984468
J250CXEIE, J250TXEIE 1991
J250CXEND, J250CZEND, J250TXEND, J250TZEND 1992
J250CXEOR, J250CZEOR, J250TXEOR, J250TZEOR 1995
J275CXCCA, J275PLCCA, J275PXCCA 1988
J300CXCCA, J300PLCCA, J300PXCCA 1988
J300CXCEM, J300PLCEM, J300PXCEM 1989
J300CXEIE, J300PLEIE, J300PXEIE 1991
J300CXEND, J300PLEND, J300PXEND 1992
J300CXEOR, J300PLEOR, J300PXEOR 1995
J300CXERC, J300PLERC, J300PXERC 1994
J300CXESB, J300PLESB, J300PXESB 1990
J300CXETF, J300CXETS, J300PLETF, J300PLETS, J300PXETF, J300PXETS 1993
Information:
The aftertreatment identification module communicates with the engine ECM to ensure that the correct Integrated Clean Emissions Module (IGCEM) is installed.If the total operating hours of the engine are greater than 100, the aftertreatment identification module will cease to send the signal. The diagnostic codes that are listed in Table 1 will be disabled.
Illustration 1 g06142837
Schematic for the aftertreatment identification module
Illustration 2 g02174636
View of the pin locations on the 31-pin connector and the 40-pin connector for the aftertreatment identification module
Illustration 3 g02013237
View of the pin locations on the P2 connector for the aftertreatment identification module
(18) Aftertreatment identification module signal
(36) Aftertreatment identification module return
(45) CEM 5 VDC supply
Illustration 4 g02084579
Typical example of the connector for the aftertreatment identification module
(1) 5 VDC Supply
(3) Signal
(6) GroundComplete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Diagnostic Codes
A. Establish communication between the electronic service tool and the Dosing Control Unit (DCU) . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Turn the keyswitch to the ON position.
C. Look for "-2", "-8", or "-14" active or logged codes.
Diagnostic code
Result: A 5576-2 (3468-2) or 5576-14 (3468-14) diagnostic code is active.
Proceed to Test Step 9.
Result: A 5576-8 (3468-8) diagnostic code is active.
Proceed to Test Step 2.
2. Inspect Electrical Connectors and Wiring
A. Inspect the P2/J2 connector. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
B. Inspect the 31-pin connector and the 40-pin connector. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Inspect the connector for the aftertreatment identification module. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
D. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the aftertreatment identification module.
E. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
F. Check the harness for abrasion and pinch points from the aftertreatment identification module back to the ECM.
Connectors and wiring
Result: There is a fault with the harness or the connectors.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all the seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair has eliminated the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 3.
3. Measure the Voltage to the Aftertreatment Identification Module
A. Turn the keyswitch to the OFF position.
B. Disconnect the aftertreatment identification module from the harness.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the harness connector for the aftertreatment identification module from terminal 1 to terminal 6.
4.84 to 5.16 VDC.
Result: The supply voltage is out of the nominal range.
Proceed to Test Step 4.
Result: The supply voltage is correct.
Proceed to Test Step 6.
4. Measure the Voltage to the 40-Pin Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the 40-pin connector.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the 40-pin connector on the harness between the engine and the CEM from pin 1 to pin 28.
4.84 to 5.16 VDC
Result: The voltage is within the expected range. The fault is in the harness.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: The voltage is out of the expected range.
Reconnect the 40-pin connector. Proceed to Test Step 5.
5. Measure the Voltage to the 31-Pin Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the 31-pin connector.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the 31-pin connector on the engine harness from pin 1 to pin 28.
4.84 to 5.16 VDC
Result: The voltage is within the expected range. The fault is in the harness between the 31-pin connector and the 40-pin connector.
Repair: Repair the faulty wiring or r
Illustration 1 g06142837
Schematic for the aftertreatment identification module
Illustration 2 g02174636
View of the pin locations on the 31-pin connector and the 40-pin connector for the aftertreatment identification module
Illustration 3 g02013237
View of the pin locations on the P2 connector for the aftertreatment identification module
(18) Aftertreatment identification module signal
(36) Aftertreatment identification module return
(45) CEM 5 VDC supply
Illustration 4 g02084579
Typical example of the connector for the aftertreatment identification module
(1) 5 VDC Supply
(3) Signal
(6) GroundComplete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Diagnostic Codes
A. Establish communication between the electronic service tool and the Dosing Control Unit (DCU) . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Turn the keyswitch to the ON position.
C. Look for "-2", "-8", or "-14" active or logged codes.
Diagnostic code
Result: A 5576-2 (3468-2) or 5576-14 (3468-14) diagnostic code is active.
Proceed to Test Step 9.
Result: A 5576-8 (3468-8) diagnostic code is active.
Proceed to Test Step 2.
2. Inspect Electrical Connectors and Wiring
A. Inspect the P2/J2 connector. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
B. Inspect the 31-pin connector and the 40-pin connector. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
C. Inspect the connector for the aftertreatment identification module. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
D. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the aftertreatment identification module.
E. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
F. Check the harness for abrasion and pinch points from the aftertreatment identification module back to the ECM.
Connectors and wiring
Result: There is a fault with the harness or the connectors.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all the seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair has eliminated the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 3.
3. Measure the Voltage to the Aftertreatment Identification Module
A. Turn the keyswitch to the OFF position.
B. Disconnect the aftertreatment identification module from the harness.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the harness connector for the aftertreatment identification module from terminal 1 to terminal 6.
4.84 to 5.16 VDC.
Result: The supply voltage is out of the nominal range.
Proceed to Test Step 4.
Result: The supply voltage is correct.
Proceed to Test Step 6.
4. Measure the Voltage to the 40-Pin Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the 40-pin connector.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the 40-pin connector on the harness between the engine and the CEM from pin 1 to pin 28.
4.84 to 5.16 VDC
Result: The voltage is within the expected range. The fault is in the harness.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to verify that the repair eliminates the fault.
Result: The voltage is out of the expected range.
Reconnect the 40-pin connector. Proceed to Test Step 5.
5. Measure the Voltage to the 31-Pin Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the 31-pin connector.
C. Turn the keyswitch to the ON position.
D. Measure the voltage at the 31-pin connector on the engine harness from pin 1 to pin 28.
4.84 to 5.16 VDC
Result: The voltage is within the expected range. The fault is in the harness between the 31-pin connector and the 40-pin connector.
Repair: Repair the faulty wiring or r
Parts rubber JOHNSON:
0391774
0391774 RUBBER MOUNT, Lower, hi perf.
CJ300TLCOS, J100STLCCA, J100STLCEM, J100STLESB, J110MLCCA, J110MLCDC, J110MLCEM, J110MLCUR, J115MLCIH, J115MLCNB, J115MLCOS, J115MLCRD, J115MLCTE, J115MLESB, J140MLCIH, J140MLCNB, J140MLCTE, J140TLCRD, J150CXCCA, J150CXCEM, J150CXESB, J150GTLCUR, J15
0395539
0395539 RUBBER MOUNT ASSY., Upper
BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, J120TLAEM, J120TLAIE, J120TLAND, J120TLARC, J120TLASB, J120TLATF, J120TLCCA, J120TLCDC, J120TLCOS, J120TLCUR, J125ESXENR, J125ESXERK, J125ESXE
0394701
0394701 RUBBER MOUNT, Lower
CJ275TLCDC, CJ275TLCOS, J275CLCUR, J275CXCCA, J300CLCUR, J300CXCCA, J300CXCEM, J300CXESB
0432017
0432017 RUBBER MOUNT ASSY., Upper
BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, J185ESERK, J185ESXETA, J200CXARC, J200CXATF, J200CXECM, J200CXEOC, J200CXEUA, J200WPXEEN, J200WPXSIF, J200WPXSSC, J225CXARC, J225CXATF, J225CXECS, J225CXEDE, J225CXEO
0434632
0434632 RUBBER MOUNT, Lower
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC
0434629
0434629 RUBBER MOUNT, Lower, High Perf. green, 175STL
BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, J150CXEES, J150CXEIE, J150CXSDE, J150CXSNF, J150CXSOB, J15
0434633
0434633 RUBBER MOUNT, Lower
J250CXARC, J250CXATF, J250CXEIE, J250CXEND, J250CXEOR, J300CXEIE, J300CXEND, J300CXEOR, J300CXERC, J300CXETF