0130538 SCREW,Throttle control cover JOHNSON
33E69A, 33E69A, 33E70M, 33E70M, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40R69R, 40R70A, RD-30A, RX-16M
SCREW
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- LOWER UNIT GROUP » 0130538
33E70M, 33EL70M, 33R70M, 33RL70M 1970
33E70M, 33EL70M, 33R70M, 33RL70M 1970
40E71B, 40E71G, 40EL71B, 40EL71G, 40R71B, 40R71G, 40RL71B, 40RL71G 1971
40E72E, 40EL72E, 40R72E, 40RL72E 1972
40E73D, 40EL73D, 40R73D, 40RL73D 1973
40E74S, 40EL74S, 40R74S, 40RL74S 1974
40E75C, 40EL75C, 40R75C, 40RL75C 1975
40E76A, 40E76R, 40EL76A, 40EL76R, 40R76A, 40R76R, 40RL76A, 40RL76R 1976
40R69R, 40RL69R 1969
40R70A, 40RL70A 1970
RD-30A, RD-30D, RD-30S, RDL-30A, RDL-30D, RDL-30S 1968
RX-16M, RX-16R, RXE-16M, RXE-16R, RXEL-16M, RXEL-16R, RXL-16M, RXL-16R 1968
Information:
Table 1
Diagnostic Trouble Codes for the CAN Data Link Circuit
J1939 Code CDL Code Code Description Comments
639-9 247-9 J1939 Network #1 : Abnormal Update Rate Another controller has incorrectly stopped transmitting a J1939 speed request (TSC1) or another controller has incorrectly started transmitting a J1939 speed request.
The ECM will log the diagnostic code.
The engine will not start.
1231-9 2348-9 J1939 Network #2 : Abnormal Update Rate An OEM unit has incorrectly stopped transmitting data or the soot sensor has incorrectly started transmitting a data request.
The ECM will log the diagnostic code.
The engine will not start.
1235-9 5856-9 J1939 Network #3 : Abnormal Update Rate The Pump, Electronics, and Tank Unit (PETU), the soot sensor, or a NOx sensor has incorrectly stopped or started transmitting a data request.
The ECM will log the diagnostic code. The following background information is related to this procedure:The CAN data links are also known as J1939 data links. A data link is an industry standard for sending data between different devices in the same application.High-speed data is transferred via the data links. The data links cannot be accurately tested without complicated equipment. The data links require a resistance of 60 Ohms between the two wires to transmit the data correctly. This resistance is made up of two 120 Ohm resistors. The two resistors are known as "Terminating Resistors". The terminating resistors should be at opposite ends of a data link circuit. If this resistance is not present, then the data will be intermittent or unreadable.Note: The wiring for a J1939 data link is a shielded twisted-pair cable. If the wiring is damaged, the replacement type must be shielded twisted-pair cable.-9 Detected Problems:ECM 1 is unable to communicate on the data link.
ECM 1 cannot communicate with other ECM's on the data link, but can communicate with the service tool. This situation indicates a problem with the data link wiring.ECM 1 is unable to communicate with ECM 2 on the data link.
ECM 1 cannot communicate with ECM 2, indicating a problem with the data link wiring, power or ground circuit, or ECM 2.
Illustration 1 g06208024
Typical example of the schematic for the CAN A data link
Illustration 2 g03810547
Typical example of the schematic for the CAN B data link
Illustration 3 g06208032
Typical example of the schematic for the CAN C data link
Illustration 4 g03132596
Typical view of the pin locations on the P1 connector
(13) CAN B+
(17) CAN C+
(18) CAN C-
(21) CAN B-
(25) CAN A+
(26) CAN A-Complete the procedure in the order in which the steps are listed.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Associated Diagnostic Trouble Codes
A. Establish communication between the electronic service tool and the ECM. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Troubleshoot any associated diagnostic codes that are present before continuing with this procedure.
Associated Codes
Result: Another diagnostic trouble code is not active or logged.
Proceed to Test Step 2.
Result: Another code is active or logged.
Repair: Troubleshoot the other codes before continuing with this procedure.
Refer to Troubleshooting, "Diagnostic Trouble Codes" to troubleshoot the other diagnostic code.
2. Use the "System Communication Status" to Determine the Communication Issue
A. In the electronic service tool, click the "Diagnostics" tab on the tool bar.
B. Select the "System Communication Status" option from the drop-down list.
Note: The Aftertreatment #1 Intake NOx Level Sensor is displayed as Aftertreatment #1 Information #1 in some versions of software.
Component Identified
Result: A -9 or -2 code is active.
Repair: Refer to the above -9 detected problems for more information.
Proceed to Test Step 3.
3. Use the System Communication Status to Determine the Cause
A. Determine if both ECM 1 and ECM 2 are present in the "ECMs" column (1) within the "System Communication Status" screen.
Note: The Aftertreatment #1 Intake NOx Level Sensor is displayed as Aftertreatment #1 Information #1 in some versions of software.
Component Identified
Result: ECM 1 and ECM 2 are both present.
Record the devices identified as ECM 1 and ECM 2 in column 1.
Proceed to Test Step 4.
Result: Only ECM 1 is present.
Record the device identified as ECM 1 in column 1.
Proceed to Test Step 5.
4. Check the Resistance of the Data link
A. Turn the keyswitch to the OFF position.
B. Measure the resistance of the datalink between ECM 2 datalink (+) wire and the datalink (-) wire on the wiring harness connector of ECM 2. Refer to the appropriate wiring diagram.
60+/-10 Ohms
Result: The resistance is less than 50 Ohms.
There are more than two terminating resistors installed in the wiring harness or a short circuit has been detected.
Repair: Repair or replace parts as necessary.
Proceed to Test Step 7.
Result: The resistance is 60 10 Ohms.
The terminating resistors are OK.
Proceed to Test Step 5.
Result: The resistance is 120 10 Ohms.
There is a problem with a terminating resistor.
Repair: Check the resistance on each terminating resistor. Replace the failed terminating resistor.
Proceed to Test Step 7.
Result: The resistance is greater than 130 Ohms.
There is a problem with both terminating resistors or an open circuit has been detected.
Repair: Determine the cause of the problem. Repair the problem, when possible. Replace parts, if necessary. Verify that the problem is resolved.
Proceed to Test Step 7.
5. Check the Power and Ground to ECM 2
A. Turn the keyswitch to the ON position.
B. Measure the voltage between the battery (+) and battery (-) terminals on the wiring harness connector of ECM 2. Refer to the appropriate wiring diagram.
Battery Voltage Result: The voltage is not equal to battery volta
Parts screw JOHNSON:
0308742
0308742 SCREW,Thermostat cap
100ESL71A, 100ESL72R, 100ML79S, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL7
0301858
0301858 SCREW
20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 33E70M, 35E76G, 35E77C, 35E78R, 35E79A, 40E69R, 40E70A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40
0303247
0303247 SCREW
115ESL69E, 33E69A, 33E69A, 33E70M, 33E70M, 40E69R, 40E70A, 40E71B, 40E72E, 40R69R, 40R70A, 85ESL69E, FD-22A, RD-30A, RDS-30A, RX-16M
0309942
0309942 SCREW,Mount to housing
20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 33E70M, 35E76G, 35E77C, 35E78R, 35E79A, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, BJ20SEECB,
0311367
0311367 SCREW
33E69A, 33E69A, 33E70M, 33E70M, 40E71B, 40E72E, 40E73D, 40E74S, 40E75C, 40E76A, 40R69R, 40R70A, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, RD-30A, RX-16M
0305009
0305009 SCREW,Clamp