0310096 SCREW,Anchor plate JOHNSON
100ESL71A, 100ESL72R, 100ML79S, 115ESL70D, 115ML79R, 125ESL71C, 125ESL72R, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 50ES71S, 50ES72C, 50R79C, 55E79C, 60ES70B, 60ES71C, 65ES72S, 70EL79R, 75ELR79R, 85ESL70B, 85ESL71A, 85ESL72R, 85ML79R, 9R69S,
SCREW
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BRP JOHNSON entire parts catalog list:
- REMOTE CONTROL » 0310096
100ML79S, 100TLR79S, 100TXLR79S 1979
115ESL70D 1970
115ML79R, 115TL79R, 115TXL79R 1979
125ESL71C 1971
125ESL72R 1972
140ML79R, 140TL79R, 140TXL79R 1979
150TL79C, 150TXL79C 1979
175TL79R, 175TXL79R 1979
200TL79A, 200TXL79A 1979
235TL70A, 235TXL79A 1979
50ES71S, 50ESL71S 1971
50ES72C, 50ESL72C, 50R72C, 50RL72C 1972
50R79C, 50RL79C 1979
55E79C, 55EL79C 1979
60ES70B, 60ES70D, 60ESL70B, 60ESL70D 1970
60ES71C, 60ES71E, 60ESL71C, 60ESL71E 1971
65ES72S, 65ESL72S 1972
70EL79R 1979
75ELR79R, 75ER79R 1979
85ESL70B, 85ESL70D 1970
85ESL71A, 85ESL71H 1971
85ESL72R 1972
85ML79R, 85TL79R, 85TXL79R 1979
9R69S, 9RL69S 1969
9R70A, 9R70C, 9RL70A, 9RL70C 1970
9R71R, 9RL71R 1971
9R72M, 9RL72M 1972
9R73B, 9RL73B 1973
MQ-14D, MQ-14E, MQL-14D, MQL-14E 1968
Information:
Water
Distilled or deionized water is recommended for use in cooling systems. DO NOT use hard, tap water or salt softened tap water in engine cooling systems. If Distilled or deionized water is NOT available, use water that meets the Minimum Acceptable requirements listed in the following chart.
Water that does not meet the Minimum Acceptable limits will reduce engine service life when used in cooling systems.
If you are not sure of your water's contents, contact your Caterpillar dealer, your local water department, agricultural agent, or an independent laboratory to analyze the water.Additives
Additives must be included in all coolant mixtures. Additives help prevent the formation of rust, scale and mineral deposits. Additives protect metals from corrosion, prevent liner cavitation, and contain anti-foaming agents. Additives deplete during engine operation and need to be replenished. This is done through the addition of supplemental coolant additives (SCAs, with conventional coolants) or Extender (with Caterpillar Long Life Coolant/Antifreeze).Nitrites or nitrite and molybdate additives protect the cylinder liner from cavitation corrosion. Nitrites deplete, creating the need for SCAs or Extender. SCAs and Extender also contain other inhibitors that deplete from cooling systems.Under-concentration of additives does not provide the protection required for cooling systems. Over-concentration can cause additives to drop out of solution, deposit inside the cooling system, or form a gel in the radiator. Deposits can be in the form of sludge and scale which accumulate on hot engine surfaces, reducing cooling system effectiveness, or causing water pump leaks.To maintain conventional cooling system protection, it is necessary to monitor SCA concentration. Incorrect SCA concentration requires action to return proper additive levels to the cooling system.Glycol
Engine coolant glycol is normally one of two varieties, ethylene or propylene. Glycol raises the boiling point of water to help prevent boil-over, provides freeze protection, helps prevent water pump cavitation, and reduces cylinder liner pitting.
For ambient temperatures requiring lower freeze protection (higher than 50 percent glycol), use ethylene glycol. DO NOT use propylene glycol.
Proper anti-freeze/boil protection requires the proper ratio of glycol and Acceptable Water. Use the following charts to determine glycol concentrations to mix with Acceptable Water. Check the coolant solution periodically to ensure adequate anti-freeze/boil protection. Use the 1U-7298 Coolant Tester (°C) or use the 1U-7297 Coolant Tester (°F). The Testers give immediate, accurate readings and can be used with ethylene or propylene glycol. For more detailed specifications, refer to: Know Your Cooling System, SEBD0518, and Coolant and Your Engine, SEBD0970, or contact your Caterpillar dealer.Caterpillar Coolant Recommendations
* Preferred- Caterpillar Long Life Coolant/Antifreeze (LLCA).Conventional Antifreeze/Coolant
* Recommended- Caterpillar Diesel Engine Antifreeze/Coolant (DEAC).* Acceptable- Any low silicate coolant that meets Truck Maintenance Council (TMC) Recommended Practice (RP) 329, TMC RP330, or ASTM D4985 requirements when used with SCAs.* Permitted-A mixture of Acceptable Water and SCA, where freeze protection is not necessary.* Unacceptable- ANY high silicate coolant that is classified as meeting ASTM D3306.
Most commercial engine coolant/antifreezes are formulated for gasoline engine applications and have high silicate content. High silicates provide conditions favoring cylinder liner cavitation and corrosion. Caterpillar DOES NOT recommend these antifreezes.
Due to individual engine applications, engine cooling system maintenance practices may need periodic re-evaluation.
Never operate without thermostats in the cooling system. Thermostats maintain the engine coolant at the proper operating temperature. Cooling system problems can arise without thermostats.
Never add coolant water to an overheated engine- engine damage can result. Allow the engine to cool first. Do not add coolant water too quickly. Filling the cooling system at over 19 L (5 US gal) per minute can create air pockets in the cooling system.
When filling or adding to the coolant to the system, premix the coolant solution prior to pouring it into the cooling system. Pure undiluted glycol will freeze at -23°C (-10°F). Use a mixture in a range which will provide protection to the lowest expected outside (ambient) temperature and provide the required boil-over protection.Caterpillar Long Life Coolant/Antifreeze (LLCA)
Caterpillar's Long Life Coolant/Antifreeze (LLCA) anti-corrosion package is totally different from the conventional antifreezes that have been in use. Caterpillar LLCA is an ethylene glycol based coolant/antifreeze containing organic corrosion inhibitors and anti-foam agents with fewer nitrites than conventional coolants.LLCA was specifically designed for cooling systems in diesel and natural gas engines. LLCA may also be used in automotive applications.LLCA extends coolant life to 6,000 service hours or four years, whichever comes first. The only maintenance required for cooling systems filled with LLCA is one addition of Caterpillar Extender.Major LLCA advantages:* twice the coolant life.* considerably less maintenance.* improved corrosion protection.* better aluminum protection.* better liner protection.* fewer additives (chemicals) and no chemical drop out.* longer radiator life.* increased water pump seal life.LLCA is available premixed 50/50 with deionized water, or in concentrate, in the following quantities. A 50/50 LLCA/water solution provides freeze protection to -37°C (-34°F) and anti-boil protection to 108°C (226°F). DO NOT use LLCA at reduced concentrations (less than 50 percent), since the additives would be reduced along with the antifreeze. LLCA concentrate is available to lower the freeze point for arctic conditions. LLCA concentration can be increased to 60 percent for -52°C (-62°F) freeze protection.Extender
LLCA Extender is a liquid that is poured into the cooling system halfway through the LLCA service life.The cooling system should be treated with Extender at the 3,000 service
Distilled or deionized water is recommended for use in cooling systems. DO NOT use hard, tap water or salt softened tap water in engine cooling systems. If Distilled or deionized water is NOT available, use water that meets the Minimum Acceptable requirements listed in the following chart.
Water that does not meet the Minimum Acceptable limits will reduce engine service life when used in cooling systems.
If you are not sure of your water's contents, contact your Caterpillar dealer, your local water department, agricultural agent, or an independent laboratory to analyze the water.Additives
Additives must be included in all coolant mixtures. Additives help prevent the formation of rust, scale and mineral deposits. Additives protect metals from corrosion, prevent liner cavitation, and contain anti-foaming agents. Additives deplete during engine operation and need to be replenished. This is done through the addition of supplemental coolant additives (SCAs, with conventional coolants) or Extender (with Caterpillar Long Life Coolant/Antifreeze).Nitrites or nitrite and molybdate additives protect the cylinder liner from cavitation corrosion. Nitrites deplete, creating the need for SCAs or Extender. SCAs and Extender also contain other inhibitors that deplete from cooling systems.Under-concentration of additives does not provide the protection required for cooling systems. Over-concentration can cause additives to drop out of solution, deposit inside the cooling system, or form a gel in the radiator. Deposits can be in the form of sludge and scale which accumulate on hot engine surfaces, reducing cooling system effectiveness, or causing water pump leaks.To maintain conventional cooling system protection, it is necessary to monitor SCA concentration. Incorrect SCA concentration requires action to return proper additive levels to the cooling system.Glycol
Engine coolant glycol is normally one of two varieties, ethylene or propylene. Glycol raises the boiling point of water to help prevent boil-over, provides freeze protection, helps prevent water pump cavitation, and reduces cylinder liner pitting.
For ambient temperatures requiring lower freeze protection (higher than 50 percent glycol), use ethylene glycol. DO NOT use propylene glycol.
Proper anti-freeze/boil protection requires the proper ratio of glycol and Acceptable Water. Use the following charts to determine glycol concentrations to mix with Acceptable Water. Check the coolant solution periodically to ensure adequate anti-freeze/boil protection. Use the 1U-7298 Coolant Tester (°C) or use the 1U-7297 Coolant Tester (°F). The Testers give immediate, accurate readings and can be used with ethylene or propylene glycol. For more detailed specifications, refer to: Know Your Cooling System, SEBD0518, and Coolant and Your Engine, SEBD0970, or contact your Caterpillar dealer.Caterpillar Coolant Recommendations
* Preferred- Caterpillar Long Life Coolant/Antifreeze (LLCA).Conventional Antifreeze/Coolant
* Recommended- Caterpillar Diesel Engine Antifreeze/Coolant (DEAC).* Acceptable- Any low silicate coolant that meets Truck Maintenance Council (TMC) Recommended Practice (RP) 329, TMC RP330, or ASTM D4985 requirements when used with SCAs.* Permitted-A mixture of Acceptable Water and SCA, where freeze protection is not necessary.* Unacceptable- ANY high silicate coolant that is classified as meeting ASTM D3306.
Most commercial engine coolant/antifreezes are formulated for gasoline engine applications and have high silicate content. High silicates provide conditions favoring cylinder liner cavitation and corrosion. Caterpillar DOES NOT recommend these antifreezes.
Due to individual engine applications, engine cooling system maintenance practices may need periodic re-evaluation.
Never operate without thermostats in the cooling system. Thermostats maintain the engine coolant at the proper operating temperature. Cooling system problems can arise without thermostats.
Never add coolant water to an overheated engine- engine damage can result. Allow the engine to cool first. Do not add coolant water too quickly. Filling the cooling system at over 19 L (5 US gal) per minute can create air pockets in the cooling system.
When filling or adding to the coolant to the system, premix the coolant solution prior to pouring it into the cooling system. Pure undiluted glycol will freeze at -23°C (-10°F). Use a mixture in a range which will provide protection to the lowest expected outside (ambient) temperature and provide the required boil-over protection.Caterpillar Long Life Coolant/Antifreeze (LLCA)
Caterpillar's Long Life Coolant/Antifreeze (LLCA) anti-corrosion package is totally different from the conventional antifreezes that have been in use. Caterpillar LLCA is an ethylene glycol based coolant/antifreeze containing organic corrosion inhibitors and anti-foam agents with fewer nitrites than conventional coolants.LLCA was specifically designed for cooling systems in diesel and natural gas engines. LLCA may also be used in automotive applications.LLCA extends coolant life to 6,000 service hours or four years, whichever comes first. The only maintenance required for cooling systems filled with LLCA is one addition of Caterpillar Extender.Major LLCA advantages:* twice the coolant life.* considerably less maintenance.* improved corrosion protection.* better aluminum protection.* better liner protection.* fewer additives (chemicals) and no chemical drop out.* longer radiator life.* increased water pump seal life.LLCA is available premixed 50/50 with deionized water, or in concentrate, in the following quantities. A 50/50 LLCA/water solution provides freeze protection to -37°C (-34°F) and anti-boil protection to 108°C (226°F). DO NOT use LLCA at reduced concentrations (less than 50 percent), since the additives would be reduced along with the antifreeze. LLCA concentrate is available to lower the freeze point for arctic conditions. LLCA concentration can be increased to 60 percent for -52°C (-62°F) freeze protection.Extender
LLCA Extender is a liquid that is poured into the cooling system halfway through the LLCA service life.The cooling system should be treated with Extender at the 3,000 service
Parts screw JOHNSON:
0310302
0310302 SCREW,Pump halves
115ESL69E, 115ESL70D, 25E77S, 25E78C, 25E79R, 33E69A, 33E69A, 33E70M, 33E70M, 35E77C, 35E78R, 35E79A, 40E69R, 40E70A, 40ES69R, 40ES70A, 40R69R, 40R70A, 6R69M, 6R70B, 85ESL69E, 85ESL70B, 9R69S, 9R70A, CD-25A, J25ECIB, J25ECNE, J25ECTD, J25RCSA, J25RSA
0307151
0307151 SCREW
100ML79S, 115EL77S, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 50ES73R, 50ES7
0309720
0309720 SCREW, Cam follwer
20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 35E76G, 35E77C, 35E78R, 35E79A, 9R69S, 9R70A, 9R71R, 9R72M, 9R73B, J25ECIB, J25ECNE, J25ECTD, J25RCSA, J25RSA, J25RSLS, J3
0310053
0312139
0311752
0307175
0307175 SCREW,Switch mounting
100ESL71A, 100ESL72R, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 150TL78S, 15E77M, 15E78B, 15E79E, 175TL77
0551705