0314880 SEAL,Impeller housing plate JOHNSON
115EL77S, 85EL76D, 85EL77S
SEAL
Price: query
Rating:
BRP JOHNSON entire parts catalog list:
Information:
Illustration 1 g00835551
Typical schematicTest Step 1. Check for an Open Circuit in the OFF/RESET position.
If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the Generator Terminal box.
Disconnect the harness connector from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Turn the ECS to the OFF/RESET position.
At the GSC+ harness connector, measure the resistance from contact "39" to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "39" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - All resistance measurements are correct. Proceed to test step 2.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete.STOPTest Step 2. Check for an Open Circuit in the AUTO position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "40" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 3.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 3. Check for an Open Circuit in the MAN/START position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "33" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 4.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 4. Check for an Open Circuit in the COOLDOWN/STOP position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Parts seal JOHNSON:
0315403
0315403 SEAL, Valve housing
100ESL71A, 100ESL72R, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 85EL77S, 85ESL69E, 85ESL70B, 85ESL71A, 85ESL72R, 85ESL73M, 85ESL74B, 85ESL75E
0314964
0314964 SEAL, Cyl. to crankcase
100ESL71A, 100ESL72R, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 85EL76D, 85EL77S, 85ESL69E, 85ESL70B, 85ESL71A, 85ESL72R, 85ESL73M
0318451
0318451 SEAL, Upper
115ESL73M, 115ESL74B, 115ESL75E, 135ESL73M, 135ESL74B, 135ESL75E, 200TL76S, 85EL76D, 85ESL73M, 85ESL74B, 85ESL75E
0319244
0319244 SEAL RING, One stripe
100ML79S, 115EL77S, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85EL76D, 85EL7
0319197
0319197 SEAL RING, Three stripes
100ML79S, 115EL77S, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85EL76D, 85EL7
0319250
0319250 SEAL RING, Two stripes
100ML79S, 115EL77S, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85EL76D, 85EL7
0321668
0321668 SEAL
100ML79S, 115EL77S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 40E76A, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, 70EL76D, 7
0322575
0322575 SEAL,Upper
100ML79S, 115EL77S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85EL77S, 85ETLR78C, 85ML79R, 85TXLR77S, CJ275TLCDC, CJ275TLCOS, CJ30