0341280 SEAL, Driveshaft JOHNSON
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115TLEDA, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ200CXEDR, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, BJ90ELEDR, BJ90ELEUA, BJ90SLECM, HJ88MSLEDC, H
SEAL
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
18-8300 Oil Seal Compatible with Johnson Evinrude OMC 0341280 341280 878966
PARTSDEPOT 18-8300 Oil Seal Compatible with Johnson Evinrude OMC 0341280 341280 878966 || Bin Location 3-132 || Manufacturer Part Number 341280 replacement || Compatible with Johnson Evinrude OMC
PARTSDEPOT 18-8300 Oil Seal Compatible with Johnson Evinrude OMC 0341280 341280 878966 || Bin Location 3-132 || Manufacturer Part Number 341280 replacement || Compatible with Johnson Evinrude OMC
$21.95
20-03-2022
1.0[0.45] Pounds
-: -
Johnson Evinrude OMC New OEM Driveshaft Seal, 0341280
SKU: 0341280 || Sold Each || Please verify your own fitment || Superseded From: 0769163
SKU: 0341280 || Sold Each || Please verify your own fitment || Superseded From: 0769163
Compatible models:
BJ115ELEDR
BJ115ELEUA
BJ115GLECM
BJ115TLEDA
BJ130TLECE
BJ130TLEDM
BJ130TLEUB
BJ150ELECD
BJ150ELEDB
BJ150ELEUC
BJ175EXECD
BJ175EXEDB
BJ175EXEUC
BJ200CXEDR
BJ250CXECB
BJ250CXEDA
BJ250CXEUM
BJ90ELEDR
BJ90ELEUA
BJ90SLECM
HJ88MSLEDC
J100WQLECS
J100WTLEDR
J100WTLEOC
J100WTLEUA
J112TSLEDR
J112TSLEOC
J115ELEOC
J115FSLECS
J115JKLEOC
J115JLEOR
J115TSLECM
J115TSLEUA
J125WTPLE
J130CXAOR
J150ELEOM
J150FCXECR
J150ICXEUC
J150WTLEOR
J175EXEOM
J175FCXECS
J200CXECM
J200CXEOC
J200CXEUA
J225CXECS
J225CXEDE
J225CXEOB
J225CXEUD
J250CXECD
J250CXEOR
J300CXEOR
J85TTLEOR
J88MSLEOS
J88TSLEDR
J88TSLEOC
J90ELEOC
J90FSLECS
J90TSLECM
J90TSLEUA
SJ100WMPLM
SJ100WMPLZ
SJ105RWLP
SJ125RWYJ
SJ125RWYN
SJ125RWYV
SJ125WTPLJ
SJ125WTPLN
SJ125WTPLV
SJ150WTPLB
SJ150WTPLT
SJ200WTPLA
SJ200WTPLS
JOHNSON
BRP JOHNSON entire parts catalog list:
BJ115ELEUA, BJ115ELEUC, BJ115GLEUA, BJ115GLEUC, BJ115SXEUA, BJ115SXEUC, HJ115SLEUA, HJ115SLEUC, J115ELEUA, J115ELEUC, J115GLEUA, J115GLEUC, J115SLEUA, J115SLEUC, J115SXEUA, J115SXEUC 1997
BJ115GLECM, BJ115SXECM, HJ115SLECM, J115ELECM, J115GLECM, J115JTLECS, J115SLECM, J115SXECM 1998
BJ115TLEDA, HJ115TXADA, J115JLEDA, J115TLEDA, J115TXADA 1996
BJ130TLECE, HJ130TXACB, J130TLECE, J130TXACB 1998
BJ130TLEDM, HJ130CXADA, HJ130TXADA, J130TLEDM, J130TXADA, SJ130CXADA, SJ130TLEDM, SJ130TXADA 1996
BJ130TLEUB, HJ130CXAUM, HJ130TXAUM, J130TLEUB, J130TXAUM 1997
BJ150ELECD, BJ150EXECD, BJ150GLECD, BJ150NXECD, J150ELECD, J150EXECD, J150GLECD, J150JLECD, J150NXECD, J150SLECD 1998
- GEARCASE -- STANDARD ROTATION -- GL MODELS
- GEARCASE -- COUNTER-ROTATION
- GEARCASE-STD ROTATION-20" 150SL, EL, 175SL & ALL 25" MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE - STD. ROTATION - 20" 150SL, EL, 175SL & ALL 25
- GEARCASE - STANDARD ROTATION - GL MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE-STANDARD ROTATION - 20" 150SL, EL, 175SL & ALL 25
- GEARCASE - STANDARD ROTATION - GL MODELS
- GEARCASE -- COUNTER-ROTATION
- GEARCASE-STD ROTATION-20" 150SL, EL, 175SL & ALL 25" MODELS
- GEARCASE -- STANDARD ROTATION -- GL MODELS
- GEARCASE - STANDARD ROTATION - GL MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE - STD. ROTATION - 20" 150SL, EL, 175SL & ALL 25
- GEARCASE - COUNTER-ROTATION
- GEARCASE-STANDARD ROTATION - 20" 150SL, EL, 175SL & ALL 25
- GEARCASE - STANDARD ROTATION - GL MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
BJ250CXEDA, BJ250TXEDA 1996
BJ250CXEUM, BJ250TXEUM 1997
BJ90ELEDR, BJ90SLEDR, J90ELEDR, J90SLEDR, SJ90ELEDR 1996
BJ90ELEUA, BJ90ELEUC, BJ90SLEUA, BJ90SLEUC, BJ90SXEUA, BJ90SXEUC, J90ELEUA, J90ELEUC, J90SLEUA, J90SLEUC 1997
BJ90SLECM, BJ90SXECM, J90ELECM, J90SLECM 1998
BJ90TLEDA, HJ88MSLEDC, HJ90MLEDA, HJ90TXADA, J88MSLEDC, J90TLEDA 1996
HJ88MSLEDC, J88MSLEDC 1996
J100WQLECS, J100WQXECS 1998
J100WTLEDR, J100WTXEDR 1996
J100WTLEOC, J100WTXEOC 1995
J100WTLEUA, J100WTXEUA 1997
J112TSLEDR, J112TSXEDR, XJ112TSLEDR, XJ112TSXEDR 1996
J112TSLEDR, J112TSXEDR, XJ112TSLEDR, XJ112TSXEDR 1996
J112TSLEOC, J112TSXEOC, XJ112TSLEOC, XJ112TSXEOC 1995
J112TSLEOC, J112TSXEOC, XJ112TSLEOC, XJ112TSXEOC 1995
J115ELEOC, J115GLEOC, J115SLEOC, J115SXEOC 1995
J115FSLECS, J115FSXECS, J115FTLECS 1998
J115JKLEOC 1995
J115JLEOR, J115MLEOR, J115TLEOR, J115TXAOR 1995
J115TSLECM, J115TSXECM, XJ115HLECM, XJ115HXECM 1998
J115TSLEUA, J115TSXEUA, XJ115HLEUA, XJ115HXEUA 1997
J125WTPLE 1995
J130CXAOR, J130TLEOA, J130TXAOR 1995
J150ELEOM, J150EXEOM, J150GLEOM, J150JLEOM, J150NXEOM, J150SLEOM, VJ150HLEOS 1995
- GEARCASE - COUNTER ROTATION
- GEARCASE - STANDARD ROTATION-20" 150SL,175SL -ALL 25" MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE -- COUNTER-ROTATION -- FCX MODELS
- GEARCASE -- STANDARD ROTATION -- IL & FTL MODELS
- GEARCASE -- STANDARD ROTATION -- FSL & FSX MODELS
- GEARCASE -- STANDARD ROTATION -- IL MODELS
- GEARCASE -- COUNTER-ROTATION -- ICX MODELS
- GEARCASE -- STANDARD ROTATION -- PL & IX MODELS
J175EXEOM, J175GLEOM, J175NXEOM, J175SLEOM 1995
- GEARCASE - COUNTER ROTATION
- GEARCASE - STANDARD ROTATION-20" 150SL,175SL -ALL 25" MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE -- STANDARD ROTATION -- IL & FTL MODELS
- GEARCASE -- STANDARD ROTATION -- FSL & FSX MODELS
- GEARCASE -- COUNTER-ROTATION -- FCX MODELS
- GEARCASE -- COUNTER-ROTATION -- CX, CZ, NX MODELS
- GEARCASE - STANDARD ROTATION - PX, PZ, TL, TX, TZ, QX MODELS
- GEARCASE -- STANDARD ROTATION -- GL, SL, & STL MODELS
- GEARCASE - COUNTER ROTATION
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE -- COUNTER-ROTATION -- CX, CZ, NX MODELS
- GEARCASE - STANDARD ROTATION - PX, PZ, TL, TX, TZ, QX MODELS
- GEARCASE -- STANDARD ROTATION -- GL, SL, & STL MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE - COUNTER-ROTATION
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE - COUNTER ROTATION
- GEARCASE - COUNTER-ROTATION
- GEARCASE - STANDARD ROTATION - 25 IN. & 30 IN. MODELS
- GEARCASE - STANDARD ROTATION - 20 IN. MODELS
- GEARCASE -- COUNTER-ROTATION -- CX, CZ, NX MODELS
- GEARCASE - STANDARD ROTATION - PX, PZ, TL, TX, TZ, QX MODELS
- GEARCASE -- STANDARD ROTATION -- GL, SL, & STL MODELS
J300CXEOR, J300PLEOR, J300PXEOR 1995
J85TTLEOR 1995
J88MSLEOS, J90JLEOR, J90MLEOR, J90TLEOR 1995
J88MSLEOS 1995
J88TSLEDR, XJ88TSLEDR 1996
J88TSLEDR, XJ88TSLEDR 1996
Information:
The release of hydraulic pressure in an hydraulic circuit is required before service is performed to that hydraulic circuit. Release the pressure in the following hydraulic circuits before any hydraulic lines are disconnected from that hydraulic circuit or hydraulic components are removed.
Boom hydraulic circuit
Stick hydraulic circuit
Bucket hydraulic circuit
Swing hydraulic circuit
Travel hydraulic circuit
Attachment hydraulic circuits (if equipped)
Pilot hydraulic circuit
Return hydraulic circuitRelease Of Hydraulic Pressure From A Single Hydraulic Circuit
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the attachments have been lowered, oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Perform the following Steps in order to release the hydraulic pressure from a single hydraulic circuit of the main hydraulic system.
Position the machine on level ground.
Illustration 1 g00666865
Fully retract the stick cylinder rod. Adjust the position of the bucket so that the bucket is parallel to the ground. Lower the boom until the bucket is flat on the ground. Refer to Illustration 1.
Shut off the engine.
Turn the engine start switch to the ON position without starting the engine.
Place the hydraulic activation control lever in the UNLOCKED position.
Move only the joysticks or the pedals of the hydraulic circuit that requires service to the FULL STROKE positions. This will release the high pressure only in that single hydraulic circuit. This will also release any pressure that might be present in the pilot hydraulic circuit.Note: If the desired hydraulic circuit that requires service requires the activation of a switch for operation, activate the necessary switches for the operation of the hydraulic circuit.
Place the hydraulic activation control lever in the LOCKED position.
Turn the engine start switch to the OFF position.
Slowly loosen the filler cap on the hydraulic tank and release the pressure from the hydraulic tank. Leave the filler cap loose for a minimum of 45 seconds. This will release the pressure that may be present in the return hydraulic circuit.
Tighten the filler cap on the hydraulic tank.
The pressure in the single hydraulic circuit that requires service is now released and lines and components can be disconnected or removed from that hydraulic circuit.Release Of Hydraulic Pressure From Multiple Hydraulic Circuits
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the attachments have been lowered, oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Perform the following Steps in order to release the hydraulic pressure from multiple hydraulic circuits of the main hydraulic system.
Position the machine on level ground.
Illustration 2 g00666865
Fully retract the stick cylinder rod. Adjust the position of the bucket so that the bucket is parallel to the ground. Lower the boom until the bucket is flat on the ground. Refer to Illustration 2.
Shut off the engine.
Turn the engine start switch to the ON position without starting the engine.
Place the hydraulic activation control lever in the UNLOCKED position.
Move only the joysticks or the pedals of the hydraulic circuit that requires service to the FULL STROKE positions. This will release the high pressure only in that hydraulic circuit. This will also release any pressure that might be present in the pilot hydraulic circuit.Note: If the hydraulic circuit that requires service requires the activation of a switch for operation, activate the necessary switches for the operation of the hydraulic circuit.
Place the hydraulic activation control lever in the LOCKED position.
Start the engine.
Place the hydraulic activation control lever in the UNLOCKED position. Do not move any joysticks or pedals from the NEUTRAL position during this step. Do not activate any switches during this Step.
Return the hydraulic activation control lever to the LOCKED position.
Shut off the engine.
Repeat Steps 4 through 11 for each additional hydraulic circuit that requires service.
After releasing the hydraulic pressure in each of the desired hydraulic circuits, place the hydraulic activation control lever in the LOCKED position.
Turn the engine start switch to the OFF position.
Slowly loosen the filler cap on the hydraulic tank and release the pressure. Leave the filler cap loose for a minimum of 45 seconds. This will release the pressure that may be present in the return hydraulic circuit.
Tighten the filler cap on the hydraulic tank.
The pressure in the multiple hydraulic circuits that require service is now released and lines and compone
Boom hydraulic circuit
Stick hydraulic circuit
Bucket hydraulic circuit
Swing hydraulic circuit
Travel hydraulic circuit
Attachment hydraulic circuits (if equipped)
Pilot hydraulic circuit
Return hydraulic circuitRelease Of Hydraulic Pressure From A Single Hydraulic Circuit
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the attachments have been lowered, oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Perform the following Steps in order to release the hydraulic pressure from a single hydraulic circuit of the main hydraulic system.
Position the machine on level ground.
Illustration 1 g00666865
Fully retract the stick cylinder rod. Adjust the position of the bucket so that the bucket is parallel to the ground. Lower the boom until the bucket is flat on the ground. Refer to Illustration 1.
Shut off the engine.
Turn the engine start switch to the ON position without starting the engine.
Place the hydraulic activation control lever in the UNLOCKED position.
Move only the joysticks or the pedals of the hydraulic circuit that requires service to the FULL STROKE positions. This will release the high pressure only in that single hydraulic circuit. This will also release any pressure that might be present in the pilot hydraulic circuit.Note: If the desired hydraulic circuit that requires service requires the activation of a switch for operation, activate the necessary switches for the operation of the hydraulic circuit.
Place the hydraulic activation control lever in the LOCKED position.
Turn the engine start switch to the OFF position.
Slowly loosen the filler cap on the hydraulic tank and release the pressure from the hydraulic tank. Leave the filler cap loose for a minimum of 45 seconds. This will release the pressure that may be present in the return hydraulic circuit.
Tighten the filler cap on the hydraulic tank.
The pressure in the single hydraulic circuit that requires service is now released and lines and components can be disconnected or removed from that hydraulic circuit.Release Of Hydraulic Pressure From Multiple Hydraulic Circuits
Personal injury can result from hydraulic oil pressure and hot oil.Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system.Make sure all of the attachments have been lowered, oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Perform the following Steps in order to release the hydraulic pressure from multiple hydraulic circuits of the main hydraulic system.
Position the machine on level ground.
Illustration 2 g00666865
Fully retract the stick cylinder rod. Adjust the position of the bucket so that the bucket is parallel to the ground. Lower the boom until the bucket is flat on the ground. Refer to Illustration 2.
Shut off the engine.
Turn the engine start switch to the ON position without starting the engine.
Place the hydraulic activation control lever in the UNLOCKED position.
Move only the joysticks or the pedals of the hydraulic circuit that requires service to the FULL STROKE positions. This will release the high pressure only in that hydraulic circuit. This will also release any pressure that might be present in the pilot hydraulic circuit.Note: If the hydraulic circuit that requires service requires the activation of a switch for operation, activate the necessary switches for the operation of the hydraulic circuit.
Place the hydraulic activation control lever in the LOCKED position.
Start the engine.
Place the hydraulic activation control lever in the UNLOCKED position. Do not move any joysticks or pedals from the NEUTRAL position during this step. Do not activate any switches during this Step.
Return the hydraulic activation control lever to the LOCKED position.
Shut off the engine.
Repeat Steps 4 through 11 for each additional hydraulic circuit that requires service.
After releasing the hydraulic pressure in each of the desired hydraulic circuits, place the hydraulic activation control lever in the LOCKED position.
Turn the engine start switch to the OFF position.
Slowly loosen the filler cap on the hydraulic tank and release the pressure. Leave the filler cap loose for a minimum of 45 seconds. This will release the pressure that may be present in the return hydraulic circuit.
Tighten the filler cap on the hydraulic tank.
The pressure in the multiple hydraulic circuits that require service is now released and lines and compone
Parts seal JOHNSON:
0332585
0332585 SEAL
BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, CJ275TLCDC, CJ300TLCDC, D100WTLM, HJ88MSLEDC,
0333740
0333740 SEAL, Adapter to cover
BJ250CXECB, BJ250CXEDA, BJ250CXEUM, J250CXARC, J250CXATF, J250CXEIE, J250CXEND, J250CXEOR, J275CXCCA, J300CXCCA, J300CXCEM, J300CXEIE, J300CXEND, J300CXEOR, J300CXERC, J300CXESB, J300CXETF
0335655
0335655 SEAL, VRO conn.
BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, HJ55WMLM, HJ55WMLZ, J105WPLSTM, J112TSLEDR, J112TSLEDR, J112TSLEOC, J112TSLEOC, J112TSLERS, J112TSLERS, J115GLSDE, J115GLSOB, J115GLSRC, J115GLSTA, J115PLSDA, J115PLSOR, J115PLSRC, J115PXSDA, J115PXSOR, J115PXSRM, J1
0336914
0336914 SEAL ASSY.
BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLECM, HJ88MSLEDC, HJ88MSLEDC, J100STLEIE, J1
0335236
0335236 SEAL, Vapor sep. to bracket
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ90ELEDR, BJ90ELEUA, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLECM, J100
0339620
0339620 SEAL, Upper
BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, HJ88MSLEDC, HJ88MSLEDC, J100STLERC, J100STLETS
0339581
0339581 SEAL, Silencer to carb.
BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225PLSIF, BJ250CXECB, BJ250CXEDA, BJ250CXEUM, J120TLARC, J125ESXERK, J125WTPLE, J130CXAOR, J140CXARC, J1
0343613
0343613 SEAL, Carburetor body
BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ150ELECD, BJ150ELEUC, BJ175EXECD, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ90ELEUA, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLECM, J100WPLEEC, J100WPLSIF, J100WPLSSR, J100WQLECS, J10