5005469 JOHNSON Service Manual


5005469 Service Manual JOHNSON J40PL4STC, J50PL4STC Service
5005469 Service Manual JOHNSON
Rating:
99

Buy Service Manual 5005469 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$174.95
 

03-07-2021

-: -
Qty 1 AFE 5005469 DELTECH Direct Replacement GR 10 COALESCING Element
OEM Equivalent GR 10 COALESCING ELEMENT || Direct Replacement For DELTECH 5005469 || Fit, Form and Function Guarantee || Quantity 1
$198.13
 

03-07-2021

-: -
5005469 Deltech Replacement Filter Element, OEM Equivalent.
Aftermarket replacement for Deltech part number 5005469. || Guaranteed to meet or exceed specifications of OEM brand filter. || For industrial compressed air systems
Number on catalog scheme:
 

Compatible models:

BRP JOHNSON entire parts catalog list:

J40PL4STC 2003
J50PL4STC 2003

Information:


Illustration 1 g00854866
Note: The wire insulation should be in accordance with applicable local codes.Note: Both contacts for low oil pressure at low speed and low oil pressure at high speed can be wired in parallel in order to control a single oil pump.
Table 1
System    Relay    Normally Open    Normally Closed    Common    
Oil     OPLARX1     454A     454B     454C    
Oil     OPLARX2     453A     453B     453C    
Fuel     FPLARX     440A     440B     440C    
Jacket Water     JWPARX     441A     441B     441C    
Aftercooler / Oil Cooler     AWPLARX     442A     442B     442C    
Sea water     SWPLARX     443A     443B     443C     The manual start push button can be used to manually start the standby pump for the given system. Push the stop button in order to stop a standby pump that is running. When the lamp that indicates normal conditions is on, the pump will remain off. However, if the lamp that indicates normal conditions is off the standby pump will restart when you release the stop button.The lamp that indicates a normal condition will be illuminated, whenever the pressure in the monitored system is normal.Whenever the standby pump is running, the lamp that indicates that the standby pump is running will illuminate. The standby pump can be operated by the set of contacts for auto start in the standby pump panel, or the push button for manual start. The push button that is used for manual starting is found on the control panel for the standby pump.
Table 2
Lamp that indicates that the standby pump is running    Lamp that is indicating normal conditions    Indication    
On     Off     The standby pump is running. The standby pump was initiated by the standby pump panel.    
On     On     The standby pump is running. The standby pump was initiated manually.    
Off     On     Normal    
Off     Off     There is an abnormal indication. Troubleshoot lamps, wiring, and circuit operation.    Note: An extra set of normally open contacts from each of the motor starters of the standby pumps should be wired in parallel. In order to indicate that the standby pump is running, connect an indicator to these contactors. A spare input (alarm) can be used in the engine control panel. Refer to the Systems Operation, RENR2493, "3606,3608,3612 and 3616 Engines Engine Control Panel" for more information. In the marine monitoring system II, you can use a spare digital input in order to connect the contacts that are normally open. Refer to the Systems Operation, RENR2490, "Marine Monitoring System II for 3600 Engines" for more information. Power Wiring for the Starter of the Standby Pump
The power wiring for the starter of the standby pump is not shown. The motor starter needs to be compatible with the supply voltage that is used for the motor. The motor starter should also be compatible with the size of the motor that is used.Note: The wiring should be done in accordance with any local codes.