0333140 JOHNSON SHIELD, Starter spring


0333140 SHIELD, Starter spring JOHNSON J20CRCDC, J20CRCUR, J25ECDR, J25ECUA, J25RWCDC, J25RWCUR, J30ECDM, J30ECUB, J35RCDM, J35RCUB SHIELD
0333140 SHIELD, Starter spring JOHNSON
Rating:
18

Buy SHIELD, Starter spring 0333140 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 23
 

BRP JOHNSON entire parts catalog list:

J20CRCDC, J20CRLCDC, J20ECDC, J20ELCDC, J20TECDC 1986
J20CRCUR, J20CRLCUR, J20ECUR, J20ELCUR 1987
J25ECDR, J25ELCDR, J25RCDC, J25RDC, J25RLCDC, J25TECDC, J25TELCDC 1986
J25ECUA, J25ELCUA, J25RCUR, J25RLCUR, J25TECUR, J25TELCUR 1987
J25RWCDC, J25RWLCDC 1986
J25RWCUR, J25RWLCUR 1987
J30ECDM, J30ELCDM, J30RCDM, J30RLCDM, J30TECDM, J30TELCDM 1986
J30ECUB, J30ELCUB, J30RCUB, J30RLCUB, J30TECUB, J30TELCUB 1987
J35RCDM, J35RLCDM 1986
J35RCUB, J35RLCUB 1987

Information:


Illustration 1 g03346206
Schematic diagram of the ARD air pump relay circuit
Illustration 2 g03346217
View of the pin location on the P1 connector for the ARD air pump relay
(54) ARD air pump relay Test Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF position.
Check the fuses.
Check the harness for abrasion and pinch points from the relay back to the ECM and from the relay back to the battery.
Check the harness for abrasions and pinch points from the ARD air pump back to the relay.
Thoroughly inspect the relay and the connector for the relay.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the ARD air pump relay. Results:
All connectors, pins, and sockets are correctly coupled and/or inserted. The harness and connectors are free of corrosion, abrasion, and pinch points. The fuses are OK. - Proceed to Test Step 2.
There is a fault with the harness and connectors - Repair: Perform the following repair:Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all of the seals are correctly in place and ensure that the connectors are correctly connected. Replace any blown fuses.STOPTest Step 2. Override the ARD Air Pump Relay
Turn the keyswitch to the OFF position.
Connect the electronic service tool to the diagnostic connector.
Turn the keyswitch to the ON position.
Use the electronic service tool to activate the "ARD Air System Relay Override". Note: The "ARD Air System Relay


Parts shield JOHNSON:

0330831
 
0330831 SHIELD, Starter spring
BJ20SRECB, BJ20SREDA, BJ20SREUM, BJ25BAECM, BJ25BAEDR, BJ25BAEUA, BJ30BAECS, BJ30BAEDE, BJ30BAEEC, BJ30BAEUD, D25RWA, HJ20CREDA, HJ25FPO, HJ25FPV, HJ25RLEDA, HJ30REDE, J20CRCCA, J20CRCDC, J20CRCEM, J20CRCOS, J20CRCUR, J20CREIE, J20CREND, J20CREOR, J2
Back to top