5032983 SHIM (20X34X0.8mm) JOHNSON
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
SHIM
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- GEARS » 5032983
J10EL4SOR, J10R4SOA, J10RL4SOA, J10TBL4SOB, J10TE4SOA, J10TEL4SOA 2005
J10EL4SRC 2004
J10R4SDM 2006
J10R4SNF, J10RL4SNF, J10TE4SNF, J10TEL4SNF 2002
J10R4SR, J10RL4SR, J10TBL4SR, J10TE4SR, J10TEL4SR 2004
J10R4STC, J10RBL4STS, J10REL4STS, J10RL4STC, J10TBL4STC, J10TE4STC, J10TEL4STC 2003
J10R4SUB, J10RL4SUB 2007
J10RL4SDM 2006
J10TBL4SDE 2006
J10TBL4SUD, J10TE4SUB, J10TEL4SUB 2007
J10TE4SDM, J10TEL4SDM 2006
J15EL4SDC 2006
J15EL4SOS, J15R4SOA, J15RL4SOA, J15TE4SOA, J15TEL4SOA 2005
J15EL4SUR 2007
J15R4SDM 2006
J15R4SNF, J15RL4SNF, J15TE4SNF, J15TEL4SNF 2002
J15R4SR, J15TE4SR, J15TEL4SR 2004
J15R4STC, J15RL4STC, J15TE4STC, J15TEL4STC 2003
J15R4SUB, J15RL4SUB 2007
J15RL4SDM 2006
J15RL4SR 2004
J15TE4SDM, J15TEL4SDM 2006
J15TE4SUB, J15TEL4SUB 2007
Information:
Table 1
Programmable Parameters for the Electronic Ignition System    
Parameter    
"SPEED TIMING MAP"    
"DET SENSORS"    
"ENGINE TYPE"    
"LOAD TIMING MAP"    
"COMPRESSION RATIO"    
"DES ENG TIMING"    The parameters are explained below."SPEED TIMING MAP"
The selection for this parameter is based on the maximum operating speed of the engine. The map provides ignition timing that is adjusted for the engine speed. The map enhances the engine's performance at different speeds. Table 2 lists the six programmable values and the corresponding engine rpm. The default value is 01.
Table 2
Speed Timing Maps    
Value     Selection    
00     No map    
01     1200 rpm    
02     1100 rpm    
03     1000 rpm    
04     1400 rpm    
05     1500 rpm    
06     1800 rpm    The speed timing maps retard the ignition timing by six degrees for a 300 rpm reduction in engine speed. For example, if the number 01 map is selected, the desired timing can be retarded by one degree at 1150 rpm, two degrees at 1100 rpm, etc. The full six degrees of retardation is achieved at 900 rpm."DET SENSORS"
This parameter is the number of detonation sensors on the engine. If the value is programmed to zero, the protection from detonation is disabled."ENGINE TYPE"
This parameter is the engine model. The parameter must be programmed for the electronic ignition system to operate properly. The type of engine determines the firing order and the angle of the engine's banks. The type can be programmed 3408 or 3412.At start-up, the control module verifies that the configuration of the ignition transformers is correct. This confirms correct programming of the type. If this parameter is not programmed correctly, the engine will not start and a diagnostic code will be generated."LOAD TIMING MAP"
This parameter has a selection of two maps that are sensitive to the engine load. The parameter can also be disabled. Table 3 lists the three programmable values and the corresponding selection. The default value is 02.
Table 3
Load Timing Maps    
Value     Selection    
00     No map    
01     "Vacuum Advance Load Sensitive Timing"    
02     "Vacuum Retard Load Sensitive Timing"    "Vacuum Advance Load Sensitive Timing" - The engine timing is advanced by six degrees when the manifold vacuum reaches an absolute pressure of 50 kPa (7 psi)."Vacuum Retard Load Sensitive Timing" - The engine timing is retarded by six degrees when the manifold vacuum reaches an absolute pressure of 50 kPa (7 psi).The timing is retarded back to zero degrees of advance when the manifold vacuum reaches an absolute pressure of 100 kPa (15 psi).When the manifold vacuum is greater than an absolute pressure of 100 kPa (15 psi), the timing is not changed by either map."COMPRESSION RATIO"
This parameter corresponds to the compression ratio of the engine's pistons."DES ENG TIMING"
This parameter determines the desired timing at rated speed. The actual timing may vary due to the timing maps that are programmed, detonation, or operation with propane.The range for the desired timing is 9.0 to 40.0 degrees BTC.If the propane input switch is active, the range for the desired timing is 5.0 to 40.0 degrees BTC.Other Functions of the Electronic Ignition System
In addition to the programmable parameters, the EIS control module is used for the following functions:
Monitoring the components and the operation of the electronic ignition system
Timing calibration
Parts shim JOHNSON:
5032968
5032968 SHIM (20X34X1.2mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032967
5032967 SHIM (20X34X1.1mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032984
5032984 SHIM (20X34X0.9mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032982
5032982 SHIM (20X34X0.7mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032969
5032969 SHIM (20X34X1.3mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032985
5032985 SHIM (20X34X1.0mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032986
5032986 SHIM (25X34X0.7mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032988
5032988 SHIM (25X34X0.9mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD