5030885 STOP, Lower mount JOHNSON
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
STOP
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$44.24
28-11-2020
4.40924524[1.80] Pounds
-: -
Connected Essentials Fully Tailored Car Mats, Premium, Set of 4, Black with Grey Trim, 5030885
Complete set of 4 tailored car mats (2 front & 2 rear) - designed & manufactured for VW Passat Saloon and Estate 2015-Onwards || Suitable for all models of VW Passat including saloon and estate manufactured between 2015-Onwards || Manufactured in the UK from Premium automotive carpet, hand trimmed in premium grey banding - for extra strength & durability || Driver's mat with heel pad to provide double thickness - reduce wear and protect footwear || Supplied with 4 clips (fixings) to secure in place
Complete set of 4 tailored car mats (2 front & 2 rear) - designed & manufactured for VW Passat Saloon and Estate 2015-Onwards || Suitable for all models of VW Passat including saloon and estate manufactured between 2015-Onwards || Manufactured in the UK from Premium automotive carpet, hand trimmed in premium grey banding - for extra strength & durability || Driver's mat with heel pad to provide double thickness - reduce wear and protect footwear || Supplied with 4 clips (fixings) to secure in place
Compatible models:
BJ115L4SDA
BJ115L4SRC
BJ115L4STS
BJ140CX4DR
BJ140CX4SRS
BJ140L4SDR
BJ140PL4SRS
BJ60PL4SDM
BJ60PL4SOA
BJ60PL4SRR
BJ60PL4STC
BJ70PL4SDM
BJ70PL4SOA
BJ70PL4SRR
BJ70PL4STC
BJ90PL4SDA
BJ90PL4SRC
BJ90PL4STS
J115PL4SOR
J140CX4SOR
J140CX4STS
J140PL4SOR
J140PL4STS
J140PX4SOR
J60PL4SNF
J70FLTLECS
J70PL4SNF
J90PL4SOR
JOHNSON
BRP JOHNSON entire parts catalog list:
- EXHAUST HOUSING » 5030885
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140CX4STS 2003
J140PL4SOR 2005
J140PL4STS, J140PX4STS 2003
J140PX4SOR 2005
J60PL4SNF 2002
J70FLTLECS 1998
J70PL4SNF 2002
J90PL4SOR, J90PX4SOR 2005
Information:
Illustration 1 g00479965
System Schematic For Starting Motor Relay (SMR)The GSC+ uses the starting motor relay (SMR) to activate the starting motor magnetic switches ("SMMS1" and "SMMS2") and the battery charger. The SMR is located within the relay module. "SMMS1" and "SMMS2" are located on the subpanel within the control panel.Note: Whenever the GSC+ activates the SMR, "K4" is shown on the lower display. "K4" is also shown on the lower display when the GSC+ attempts to activate the crank terminate relay. When the SMR is not activated, "K4" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the SMR.The following response is the system response to this fault while the SMR is activated:
If a CID 444 occurs, then the engine stops cranking.The following response is the system response to this fault while the SMR is not activated:
If a CID 444 occurs, then the engine cannot crank or the engine cannot start. If the engine is already running, then the engine continues to run.The GSC+ treats a CID 444 as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 444 FMI 12 is showing.
If the diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 444 FMI 12 is showing as a active fault or an inactive fault. Results:
OK: A CID 444 FMI 12 has not occurred. The fault is NOT active and the fault is NOT inactive. STOP.
NOT OK: A CID 444 FMI 12is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module - Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK: Reassemble the relay module to the GSC+. Proceed to 3.
NOT OK: Replace the connector clamp if the clamp is missing. If the cable is damaged, replace the GSC+. STOP.
Perform a functional check for the SMR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-18 of the relay module.
Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-18 to RM-6. Resistance should be greater than 5000 ohms.
Prepare to measure the resistance from RM-18 to RM-6 of the relay module.
Turn the ECS to the START position. Quickly measure the resistance before the starting motor relay deactivates because of the crank time. Resistance should be less than 5 ohms.Expected Result: For 3.d, the resistance should be greater than 5000 ohms. For 3.f, the resistance should be less than 5 ohms.Results:
OK: There was probably a poor electrical connection and performing this procedure corrected the poor connection. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.
Parts stop JOHNSON:
5030911
5030886
5030886 STOP, Upper thrust
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC, J70FLTLECS
5030714
5030714 STOP, Oil pump
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030746
5030746 STOP, Thermostat, upper
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030747
5030747 STOP, Thermostat, lower
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5031593
5031593 STOP, REMOTE CABLE
BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ70PL4SDM, BJ70PL4SOA, J200CX4SOC, J200CX4SRS, J200PX4SOC, J200PX4SRS, J225CX4SOC, J225CX4SRS, J225PX4SOC
5032925
5032925 STOP, Upper thrust
BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70PL4SNF
5033567
5033567 STOP, PROPELLER BUSHING
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140PL4SOR, J140PX4SOR, J90PL4SOR