5036733 JOHNSON STOP, Upper thrust


5036733 STOP, Upper thrust JOHNSON BJ60PL4SDM, BJ70PL4SDM STOP
5036733 STOP, Upper thrust JOHNSON
Rating:
78

Buy STOP, Upper thrust 5036733 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 8
 

Compatible models:

BRP JOHNSON entire parts catalog list:

BJ60PL4SDM, J60PL4SDM 2006
BJ70PL4SDM, J70PL4SDM 2006

Information:


Table 1
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60
"J1939 Body Controller"
"J1939 Cab Controller"
"J1939 Instrument Cluster"    "Transmission Neutral Switch"
The ECM receives a signal from the transmission when the transmission is in neutral. The signal from the transmission can be broadcast over the J1939 data link or the signal can be sent directly to the ECM at terminal J1/P1:62. If a transmission neutral switch is not utilized, this parameter must be programmed to "None".
Table 2
Default     Alternative    
None     "J1/P1:62"
"J1939"    "Transmission Neutral Start Interlock"
The neutral start interlock programmable setting enables the engine ECM to listen for the crank enable or crank disable message from the transmission. The engine ECM must also control the starter relay allowing the engine to start. The neutral start interlock is used with the engine running output parameter. The engine running output parameter must be set to J1/P1: 29, 30 or 31 to enable the starter. To enable the starter, the ECM provides a path to ground.
Table 3
Default     Alternative    
Disabled     Enabled    "Ignore Brake/Clutch Switch"
This input is used for applications that require the mobile use of the vehicle with a set PTO engine set rpm that does not require the brake or the clutch to disengage the engine PTO operation.
Table 4
Default     Alternative    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60    "Torque Limit Switch"
This input limits the engine torque to a programmable value. The "Torque Limit Switch" parameter cannot be programmed if the "PTO Configuration" is programmed to "Off". If the "PTO Configuration" is programmed to "Off", the ECM will ignore the "Torque Limit Switch".
Table 5
Default     Alternative    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60    "PTO On/Off Switch"
This input allows the operator to disable the PTO.
Table 6
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60
"J1939 Body Controller"
"J1939 Cab Controller"
"J1939 Instrument Cluster"    "Remote PTO Set Switch"
This input is used when the "PTO Configuration" is programmed to "Remote Switches" or to "Remote Throttle" and the "PTO On/Off" switch is in the ON position.
Table 7
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60
"J1939 Body Controller"
"J1939 Cab Controller"
"J1939 Instrument Cluster"    "Remote PTO Resume Switch"
This input resumes PTO operation. This input is available when the "PTO Configuration" is programmed to "Remote Switches" or to "Remote Throttle" and the "PTO On/Off" switch is in the ON position.
Table 8
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60
"J1939 Body Controller"
"J1939 Cab Controller"
"J1939 Instrument Cluster"    "PTO Engine RPM Set Speed Input A"
This input is used to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches" or to "Remote Throttle" and the "PTO Engine RPM Speed Input A" parameter must be programmed to a valid speed.
Table 9
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60
"J1939 Body Controller"
"J1939 Cab Controller"
"J1939 Instrument Cluster"    "PTO Engine RPM Set Speed Input B"
This input is used to control engine speed during PTO operation. The "PTO Configuration" parameter must be programmed to "Cab Switches", to "Remote Switches" or to "Remote Throttle" and the "PTO Engine RPM Speed Input B" parameter must be programmed to a valid speed.
Table 10
Default    Alternatives    
Not Programmed     J1/P1:6, 7, 22, 23, 35, 40, 44, 45, 46, 47, 56, 58, 59, 60


Parts stop JOHNSON:

5030885
 
5030885 STOP, Lower mount
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
5030714
 
5030714 STOP, Oil pump
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030746
 
5030746 STOP, Thermostat, upper
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030747
 
5030747 STOP, Thermostat, lower
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5031593
 
5031593 STOP, REMOTE CABLE
BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ70PL4SDM, BJ70PL4SOA, J200CX4SOC, J200CX4SRS, J200PX4SOC, J200PX4SRS, J225CX4SOC, J225CX4SRS, J225PX4SOC
Back to top