0320297 JOHNSON SWIVEL BRACKET, Std.


0320297 SWIVEL BRACKET, Std. JOHNSON 50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECOB, J40ECRM, J40ECUD, J50BECCS, J50BECDE, J50BECIC, J50BECNR, J50BECOB, J50BECRM, J50BECTA, J50BECUD, J50ECSR, J55RCIM, J55RLCSA, J60ECIA, J60ECNM, J60ECS SWIVEL
0320297 SWIVEL BRACKET, Std. JOHNSON
Rating:
8

Buy SWIVEL BRACKET, Std. 0320297 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$138.95
 

08-09-2017
16.00[7.20] pounds
Evinrude: Evinrude
0320297 Johnson Evinrude Swivel Bracket (Std) Outboard 40-60hp
Evinrude||0320297, 320297||Used, no corrosion, freshwater part||1975-1988||40-60hp
Number on catalog scheme: 1
 

BRP JOHNSON entire parts catalog list:

50ES75B, 50ESL75B 1975
50R79C, 50RL79C 1979
55E76E, 55EL76E 1976
55E77D, 55EL77D 1977
55E78S, 55EL78S 1978
55E79C, 55EL79C 1979
J35AELCDE, J35ARLCDE 1986
J35AELCUD, J35ARLCUD 1987
J40AELCCS, J40ARLCCS, J40ATLCCS, J40ECCS, J40ELCCS, J40RCCS, J40RLCCS, J40TECCS, J40TELCCS, J40TLCCS, J40TTLCCS 1988
J40ECDE, J40ELCDE, J40RCDE, J40RLCDE, J40TECDE, J40TELCDE, J40TLCDE 1986
J40ECOB, J40ELCOB, J40RCOB, J40RLCOB, J40TECOB, J40TELCOB 1985
J40ECRM, J40ELCRM, J40RCRM, J40RLCRM, J40TECRM, J40TELCRM 1984
J40ECUD, J40ELCUD, J40RCUD, J40RLCUD, J40TECUD, J40TLCUD 1987
J50BECCS, J50BELCCS, J50TELCCS, J50TLCCS 1988
J50BECDE, J50BELCDE, J50TELCDE, J50TLCDE 1986
J50BECIC, J50BELCIC 1981
J50BECNR, J50BELCNR 1982
J50BECOB, J50BELCOB, J50TELCOB, J50TLCOB 1985
J50BECRM, J50BELCRM, J50TELCRM, J50TLCRM 1984
J50BECTA, J50BELCTA, J50TELCTA 1983
J50BECUD, J50BELCUD, J50TELCUD, J50TLCUD 1987
J50ECSR, J50ELCSR 1980
J55RCIM, J55RLCIM 1981
J55RLCSA 1980
J60ECIA, J60ECIH, J60ELCIA, J60ELCIH, J60TLCIA, J60TLCIH 1981
J60ECNM, J60ELCNM, J60TLCNM 1982
J60ECSR, J60ELCSR 1980
J60ECTB, J60ELCTB, J60TLCTB 1983
J60ELCOD, J60TLCOD 1985
J60ELCRE, J60TLCRE 1984

Information:


Table 1
Diagnostic Trouble Codes for the Ground Level Shutdown Switch
J1939 Code CDL Code Code Description Comments
- 266-3 Crank Without Injection Input voltage above normal The Electronic Control Module (ECM) detects the following condition:
Both contacts from the ground level shutdown switch are in the open state.
- 266-4 Crank Without Injection Input voltage below normal The Electronic Control Module (ECM) detects the following conditions:
Both contacts from the ground level shutdown switch are in the closed state.
- 267-3 Remote Shutdown Input voltage above normal The Electronic Control Module (ECM) detects the following condition:
Both contacts from the ground level shutdown switch are in the open state.
- 267-4 Remote Shutdown Input voltage below normal The Electronic Control Module (ECM) detects the following conditions:
Both contacts from the ground level shutdown switch are in the closed state. The ground level shutdown switch allows the engine to be shut down from ground level. When the switch is moved to the STOP position, the engine shuts down. The ECM remains powered. The ground level shutdown switch must be in the RUN position and the power to the ECM must be cycled before the engine can restart.
Illustration 1 g03849401
Schematic for the ground level shutdown switch
Not all connectors are shown. Refer to the Electrical Schematic for the application.
Illustration 2 g03558776
Pin locations on the P1 connector for the ground level shutdown switch.
(35) Ground level shutdown switch return
(45) Ground level shutdown switch (N/O)
(46) Ground level shutdown switch (N/C)
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the terminal connections on the P1 ECM connector and the switch connector.
Refer to Troubleshooting, "Electrical Connectors - Inspect".
B. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the ground level shutdown switch connector..
C. Check the screw for the ECM connector for the correct torque of 5 N m (44 lb in).
D. Check the harness for corrosion, abrasion, and pinch points from the solenoids to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair any faulty connectors or replace the wiring harness. Ensure that all of the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check for Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Place the ground level shutdown switch in the RUN position.
D. Turn the keyswitch to the ON position. Wait at least 20 seconds for activation of the diagnostic codes.
E. Verify if any of the diagnostic codes that are listed in Table 1 are active.
F. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: No diagnostic codes are active or logged.
Repair: The switch is operating normally. There may be an intermittent fault in the wiring harness or in a connector. Check the wiring harness and the connectors for an intermittent electrical fault. Refer to Troubleshooting, "Electrical Connector - Inspect".
Result: A 266-3 or 267-3 diagnostic is active.
Proceed to Test Step 3.
Result: A 266-4 or 267-4 diagnostic is active.
Proceed to Test Step 5.
3. Create a Short Circuit at the Shutdown Switch Connector
A. Turn the keyswitch to the OFF position.
B. Fabricate a jumper wire. Install the jumper wire between terminal 1 and terminal 2 on the harness connector for the shutdown switch.
C. Turn the keyswitch to the ON position.
D. Use the electronic service tool to check for an active 266-3 or 267-3 diagnostic code.
E. Turn the keyswitch to the OFF position. Remove the jumper wire.
Diagnostic code
Result: The 266-3 or 267-3 diagnostic code is no longer active with the jumper installed.
Repair: Install a replacement ground level shutdown switch.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The 266-3 or 267-3 diagnostic code is still active with the jumper installed.
Proceed to Test Step 4.
4. Check the (N/C) Wiring for an Open Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch. Disconnect the P1 connector from the ECM.
C. Use a multimeter to measure the resistance between terminal 1 on the shutdown switch harness connector and P1:46.
Less than 5 Ohms
Result: The measured resistance is greater than 5 Ohms.
The fault is in the wiring between the ground level shutdown switch and the P1 ECM connector.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The measured resistance is less than 5 Ohms.
Contact the Dealer Solutions Network (DSN).
5. Create an Open Circuit at the Shutdown Switch Harness Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch.
C. Turn the keyswitch to the ON position.
D. Use the electronic service tool to check for an active 266-3 or 267-3 diagnostic code.
Diagnostic code
Result: A 266-3 or 267-3 diagnostic code is active with the switch disconnected.
Repair: Install a replacement ground level shutdown switch.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: There are no active 266 or 267 diagnostic codes with the switch disconnected.
Proceed to Test Step 6.
6. Check the (N/O) Wiring for a Short Circuit
A. Turn the keyswitch to the OFF position.
B. Disconnect the harness connector for the ground level shutdown switch. Disconnect the P1 connector from the ECM.
C. Use a multimeter to check the resistance between P1:45 and all other terminals on the P1 connector.
Greater than 1 k Ohm
Result: At least one of the resistance measurements is less than 1 k Ohm.
There is a short in the wiring between the ground level shutdown switch and the P1 connector.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the


Parts swivel JOHNSON:

0315571
 
0315571 SWIVEL PLATE
50ES71S, 50ES72C, 50ES73R, 50ES74M, 50R79C, 55E79C, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECEC, J40ECUD, J40EEIA, J40EESR, J40RSLR, J40RWCDB, J40RWCOM, J40RWCRA, J45RCCDS, J45RCE, J45RCEIA, J45RCESR, J50BECCS, J50BECDE, J50BECEC, J50BECUD, J50
0318230
 
0318230 SWIVEL BRACKET,Std
50ES73R, 50R79C, 55E79C, AM55RSLD, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECOB, J40ECRM, J40ECUD, J40WREES, J40WRLSIR, J40WRLSSC, J45RCCDS, J45RCCUC, J45RCE, J45RCEIA, J45RCENM, J45RCEOD, J45RCERE, J4
0318229
 
0318229 SWIVEL BRACKET,Long
50ES73R, 50R79C, 55E79C, AM55RSLD, HJ45RCLEDS, HJ45RCLEUC, HJ55RSLC, HJ55RSLW, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECOB, J40ECRM, J40ECUD, J40WREES, J40WRLSIR, J40WRLSSC, J45RCCDS, J45RCCUC, J45RCE, J45RCEIA, J45RCENM, J45RCEOD, J45RCERE, J4
0320296
 
0320296 SWIVEL BRACKET, Long
50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, J50ECSR, J55RLCSA, J60ECSR
0326195
 
0326195 SWIVEL BRACKET, Long
HJ55WMLM, HJ55WMLZ, J35AELCDE, J35AELCUD, J40AELCCS, J40ECDE, J40ECOB, J40ECRM, J40ECUD, J45RCE, J45RCEIA, J45RCENM, J45RCESR, J48ESLCCC, J48ESLCCC, J48ESLCUS, J48ESLCUS, J50BECCS, J50BECDE, J50BECIC, J50BECNR, J50BECOB, J50BECRM, J50BECTA, J50BECUD,
Back to top