0437884 JOHNSON TERMINAL BLOCK COVER


0437884 TERMINAL BLOCK COVER JOHNSON BJ50DTLEDC, BJ50DTLEUR, BJ60ELEDR, BJ60ELEUA, BJ60TLECM, BJ70ELECB, BJ70ELEDA, BJ70ELEUM, J50DTLECA, J50TTLECA, J50TTLEDC, J50TTLEUR, J60TTLECM, J60TTLEDR, J60TTLEUA, J65WELEES, J65WELSIR, J65WELSSC, SJ65WMLD, SJ65WMLM, SJ65WMLZ2 TERMINAL
0437884 TERMINAL BLOCK COVER JOHNSON
Rating:
58

Buy TERMINAL BLOCK COVER 0437884 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 3
 

BRP JOHNSON entire parts catalog list:

BJ50DTLEDC, J50DTLEDC, J50ELED 1996
BJ50DTLEUR, J50DTLEUR, J50ELEUR 1997
BJ60ELEDR, BJ60TLEDR, J60ELEDR, J60TLEDR, SJ60TLEDR 1996
BJ60ELEUA, BJ60TLEUA, J60ELEUA, J60TLEUA 1997
BJ60TLECM, J60TLECM 1998
BJ70ELECB, BJ70TLECB, J70TLECB 1998
BJ70ELEDA, BJ70TLEDA, HJ70TXEDA, J70TLEDA, SJ70TLEDA 1996
BJ70ELEUM, BJ70TLEUM, HJ70TXEUM, J70TLEUM 1997
J50DTLECA 1998
J50TTLECA 1998
J50TTLEDC 1996
J50TTLEUR 1997
J60TTLECM 1998
J60TTLEDR 1996
J60TTLEUA 1997
J65WELEES 1999
J65WELSIR 2001
J65WELSSC 2000
SJ65WMLD, SJ65WMYD 1998
SJ65WMLM, SJ65WMYM 1996
SJ65WMLZ2, SJ65WMYZ2 1997

Information:


Illustration 1 g00291249
Typical example
Note: All water temperature regulators do not have air vent valves (1). 119-3075 Water Temperature Regulator 126-5869 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 83 °C (172 ° to 181 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.75 mm (0.345 inch) 115-4223 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 102-8392 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 107-7568 Water Temperature Regulator 7E-5254 Water Temperature Regulator 119-3075 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 93 °C (199 °F)Begin to open temperature of the water temperature regulator. ... 79 ° to 82 °C (174 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 108-7045 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 93.9 °C (201.0 °F)Begin to open temperature of the water temperature regulator. ... 81.1 ° to 83.9 °C (178 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 7C-2190 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch) 7E-1420 Water Temperature Regulator 9Y-3088 Water Temperature Regulator 9Y-3365 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 94.4 °C (202 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.1 mm (0.32 inch) 1W-8801 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 1W-8802 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.72 0.25 mm (1.170 0.010 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch)
Illustration 2 g00589065
Typical example
4W-4011 Water Temperature Regulator 120-9453 Water Temperature Regulator 6I-4954 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 89 °C (192 °F)Begin to open temperature of the water temperature regulator. ... 75 ° to 78 °C (167 ° 172 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch) 4W-4794 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 92 °C (198 °F)Begin to open temperature of the water temperature regulator. ... 81 ° to 84 °C (178 ° to 183 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch)


Parts terminal JOHNSON:

0204053
TERMINAL, Ring
0204053 TERMINAL, Ring
100ESL71A, 100ESL72R, 100ML79S, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL7
0309433
 
0309433 TERMINAL
100ML79S, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL78C, 175TL79R, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 55ES69A, 85ETLR78C, 85ML79R, BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM
0310523
 
0310523 TERMINAL
10E74G, 10E75C, 10E76G, 115TXL77S, 140ML77S, 15E74G, 15E75C, 15E76A, 20R73A, 25E73A, 25E74M, 35E76G, 40E73D, 40E74S, 40E75C, 40E76A, 55ES69A, 85TXLR77S, BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, D100WTLM, J100STLCCA, J100STLCEM, J100STLEIE, J100STLEND, J100S
0510780
 
0510780 TERMINAL
100ESL71A, 100ESL72R, 100ML79S, 10E74G, 10E77A, 10E78M, 10EL79B, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150
0510818
 
0510818 TERMINAL
100ML79S, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 23
0513851
TERMINAL, Socket
0513851 TERMINAL, Socket
BJ10EEDD, BJ10RELEUS, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSSB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ15EEDS, BJ15RELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSSC, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ
0513667
TERMINAL
0513667 TERMINAL
BJ10FDLECM, BJ10FDLEDR, BJ10FDLEUA, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ15FAEDR, BJ15FAEUA,
0513666
 
0513666 TERMINAL
BJ10FDLECM, BJ10FDLEDR, BJ10FDLEUA, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ15FAEDR, BJ15FAEUA,
Back to top