Information:

Changing the Settings of the Monitoring System
Use the following procedure to change settings of the parameters:
Select the "Service/Monitoring System" screen on Cat ET.
Highlight the desired parameter. Then click the "Change" button in the lower left corner of the screen.The "Change Monitor System" screen will appear.
Change the "State" of the parameter.
Set the "Trip Point" and the "Delay Time" according to the "Allowed Values" that are displayed in the lower half of the screen.
Click the "OK" button.If a password is required, the "Enter Passwords" screen will appear. Enter the correct passwords and then click the "OK" button.Note: If a factory password is required, the "Enter Factory Passwords" screen will appear. Refer to Troubleshooting, "Factory Passwords" for information that is related to obtaining factory passwords.The new settings will be effective immediately.Default Settings of the Monitoring System
Examples of the default settings for the parameters are listed in Table 1. The values may have changed. Use the Cat ET to determine the programming for your engine. Many of the items can be reprogrammed in order to accommodate the requirements of individual sites.
Table 1
Default Settings of the Programmable Monitoring System    
Parameter    System Response    State    Security Level
Password    Trip Point    Range    Delay in Seconds    Range of the Delay in Seconds    
E004 Engine Overspeed Shutdown     Shutdown     On     Factory     1750 rpm     1200 to 2160 rpm     0     0    
E015 High Engine Coolant Temperature Derate     Derate     Off     Customer     111 °C     80 to 129 °C     20     1 to 60    
E016 High Engine Coolant Temperature Shutdown     Shutdown     On     113 °C
E017High Engine Coolant Temperature Warning     Warning     On     109 °C
E019 High Engine Oil Temperature Shutdown     Shutdown     On     Factory     104 °C     85 to 104 °C    
E020 High Engine Oil Temperature Warning     Warning     On     Customer     102 °C     80 to 102 °C    
E025 High Inlet Air Temperature Derate (Low Engine Load)     Derate     Off     Customer     100 °C     32 to 100 °C    
E025 High Inlet Air Temperature Derate (High Engine Load)    
E026 High Inlet Air Temperature Shutdown (Low Engine Load)     Shutdown     On     70 °C
E026 High Inlet Air Temperature Shutdown (High Engine Load)     80 °C
E027 High Inlet Air Temperature Warning (Low Engine Load)     Warning     69 °C 32 to 85 °C
E027 High Inlet Air Temperature Warning (High Engine Load)     32 to 100 °C
E038 Low Engine Coolant Temperature Warning     5 °C 5 to 80 °C
E042 Low System Voltage Shutdown     Shutdown     On     Read Only     18 VDC     18 to 24 VDC     10     1 to 60    
E043 Low System Voltage Warning     Warning     20 VDC 20
E050 High System Voltage Warning     34 VDC 18 to 34 VDC
E053 Low Fuel Pressure Warning     Customer 105 kPa 100 to 135 kPa     10    
E096 High Fuel Pressure     135 kPa
E127 Engine Oil Filter Diff Pressure Low Warning     On Customer     35 kPa     7 to 80 kPa     10     1 to 60    
E128 Engine Oil Filter Diff Pressure Low Shutdown     Shutdown Factory     7 kPa    
E129 Engine Oil Filter Diff Pressure High Warning     Warning Customer     103 kPa     80 to 138 kPa    
E130 Engine Oil Filter Diff Pressure High Shutdown     Shutdown Factory     138 kPa    
E135 Low Jacket Water Pressure Shutdown     This item cannot be programmed.
E337 High Engine Oil to Engine Coolant Diff Temp     Warning     On     Customer     14 °C     0 to 20 °C     20     1 to 60    
Shutdown On     Factory     20 °C    Separate timers are used in the ECM for each response that is associated with a parameter. If a trip point is reached, the timer for that event is started.For example, the warning for "High Engine Coolant Temperature E017(1)" can be set to 95 °C with a five second delay. The timer starts counting if the coolant temperature reaches 95 °C. If the temperature is not reduced to less than 95 °C within 5 seconds, the event becomes active and the event is logged.