5035604 TUBE, WATER 15" JOHNSON
J10EL4SOR, J10EL4SRC, J10R4SR, J15EL4SOS, J15R4SR, J15RL4SR
TUBE
Price: query
Rating:
BRP JOHNSON entire parts catalog list:
- WATER PUMP » 5035604
J10R4SR, J10RL4SR, J10TBL4SR, J10TE4SR, J10TEL4SR 2004
J15EL4SOS, J15R4SOA, J15RL4SOA, J15TE4SOA, J15TEL4SOA 2005
J15R4SR, J15TE4SR, J15TEL4SR 2004
J15RL4SR 2004
Information:
Required Service Tools
Table 1
Required Service Tools
Part Number Description
7X-1710 Multimeter Probe
237-5130 Digital Multimeter (HEAVY-DUTY)
or
257-9140 Digital Multimeter
or
146-4080 Digital Multimeter Gp (RS232)
or
349-4204 Digital Multimeter Gp Two short jumper wires are needed to check the continuity of some wiring harness circuits by shorting two adjacent terminals together in a connector. A long extension wire may also be needed to check the continuity of some wiring harness circuits.Optional Service Tools
Table 2 lists the optional service tools that can be used when the engine is serviced.
Table 2
Part Number Description
198-4240
or
1U-5470 Digital Pressure Indicator
Engine Pressure Group
4C-4911(1) Battery Load Tester
6V-9130(2) Temperature Adapter (MULTIMETER)
349-4199 AC/DC Current Probe
(1) Refer to Special Instructions, SEHS9249, "Use of 4C-4911 Battery Load Tester for 6, 8, and 12 V Lead Acid Batteries" and Special Instructions, SEHS7633, "Battery Test Procedure".
(2) Refer to Special Instructions, SEHS8382, "Use of the 6V-9130 Temperature Adapter Group".Cat® Electronic Technician (ET)
Cat ET can display the following information:
Status of all pressure sensors and temperature sensors
Programmable parameter settings
Active diagnostic codes and logged diagnostic codes
Logged events
HistogramsCat ET can also be used to perform the following functions:
Diagnostic tests
Calibrations
Programming of flash file
Parameter programming
Copy configuration function for Electronic Control Module (ECM) replacement
Data logging
Graphs (real time)Table 3 lists the service tools that are required in order to use Cat ET.
Table 3
Service Tools for the Use of Cat ET
Part Number Description
N/A Required
IBM compatible PC with
266 MHz Pentium processor
64 MB of RAM
400 MB of available hard drive space
CD-ROM drive
VGA monitor or display (800 x 600)
Microsoft® Windows 2000, XP, ME,
NT 4.0 (Service Pack 4), 98, or 95
RS232 port with 16550AF UART
N/A Recommended
IBM compatible PC with
450 MHz Pentium III processor
128 MB of RAM
1 GB of available hard drive space
40X speed CD-ROM drive or
8X speed DVD drive
Super VGA monitor or display (800 x 600)
Microsoft® Windows 2000, XP, ME,
NT 4.0 (Service Pack 6), or 98
RS232 port with 16550AF UART
JERD2124 Single Use Program License
JERD2128 Data Subscription (Truck and Commercial Engine)
JERD2129 Data Subscription for All Engines and Machines
317-7484(1) Communication Adapter ("CAT ET" TO ECM INTERFACE)
327-0375(2) Adapter Cable As
(1) The 7X-1700 Communication Adapter Gp may also be used.
(2) The 327-0375 Adapter Cable As is required to connect to the USB port on computers that are not equipped with an RS232 serial port.Note: More information on the use of Cat ET and the PC requirements is in the documentation that accompanies the Cat ET software.Connecting Cat ET and the Communication Adapter Gp
Illustration 1 g01121866
(1) Personal Computer (PC)
(2) 196-0055 Adapter Cable As
(3) 275-5121 Communication Adapter Gp
(4) 332-7381 Adapter Cable As Note: Items (2), (3), and (4) are part of the 317-7484 Communication Adapter Gp.Use the following procedure in order to connect Cat ET and the Communication Adapter II.
Remove the electrical power from the ECM.
Connect cable (2) between the "COMPUTER" end of communication adapter (3) and the RS232 serial port of PC (1). Note: The 327-0375 Adapter Cable As is required to connect to the USB port on computers that are not equipped with an RS232 serial port.
Connect cable (4) between the "DATA LINK" end of communication adapter (3) and the service tool connector.
Restore the electrical power to the ECM. If Cat ET and the communication adapter do not communicate with the ECM, refer to the diagnostic procedure Troubleshooting, "Electronic Service Tool Does Not Communicate".
Table 1
Required Service Tools
Part Number Description
7X-1710 Multimeter Probe
237-5130 Digital Multimeter (HEAVY-DUTY)
or
257-9140 Digital Multimeter
or
146-4080 Digital Multimeter Gp (RS232)
or
349-4204 Digital Multimeter Gp Two short jumper wires are needed to check the continuity of some wiring harness circuits by shorting two adjacent terminals together in a connector. A long extension wire may also be needed to check the continuity of some wiring harness circuits.Optional Service Tools
Table 2 lists the optional service tools that can be used when the engine is serviced.
Table 2
Part Number Description
198-4240
or
1U-5470 Digital Pressure Indicator
Engine Pressure Group
4C-4911(1) Battery Load Tester
6V-9130(2) Temperature Adapter (MULTIMETER)
349-4199 AC/DC Current Probe
(1) Refer to Special Instructions, SEHS9249, "Use of 4C-4911 Battery Load Tester for 6, 8, and 12 V Lead Acid Batteries" and Special Instructions, SEHS7633, "Battery Test Procedure".
(2) Refer to Special Instructions, SEHS8382, "Use of the 6V-9130 Temperature Adapter Group".Cat® Electronic Technician (ET)
Cat ET can display the following information:
Status of all pressure sensors and temperature sensors
Programmable parameter settings
Active diagnostic codes and logged diagnostic codes
Logged events
HistogramsCat ET can also be used to perform the following functions:
Diagnostic tests
Calibrations
Programming of flash file
Parameter programming
Copy configuration function for Electronic Control Module (ECM) replacement
Data logging
Graphs (real time)Table 3 lists the service tools that are required in order to use Cat ET.
Table 3
Service Tools for the Use of Cat ET
Part Number Description
N/A Required
IBM compatible PC with
266 MHz Pentium processor
64 MB of RAM
400 MB of available hard drive space
CD-ROM drive
VGA monitor or display (800 x 600)
Microsoft® Windows 2000, XP, ME,
NT 4.0 (Service Pack 4), 98, or 95
RS232 port with 16550AF UART
N/A Recommended
IBM compatible PC with
450 MHz Pentium III processor
128 MB of RAM
1 GB of available hard drive space
40X speed CD-ROM drive or
8X speed DVD drive
Super VGA monitor or display (800 x 600)
Microsoft® Windows 2000, XP, ME,
NT 4.0 (Service Pack 6), or 98
RS232 port with 16550AF UART
JERD2124 Single Use Program License
JERD2128 Data Subscription (Truck and Commercial Engine)
JERD2129 Data Subscription for All Engines and Machines
317-7484(1) Communication Adapter ("CAT ET" TO ECM INTERFACE)
327-0375(2) Adapter Cable As
(1) The 7X-1700 Communication Adapter Gp may also be used.
(2) The 327-0375 Adapter Cable As is required to connect to the USB port on computers that are not equipped with an RS232 serial port.Note: More information on the use of Cat ET and the PC requirements is in the documentation that accompanies the Cat ET software.Connecting Cat ET and the Communication Adapter Gp
Illustration 1 g01121866
(1) Personal Computer (PC)
(2) 196-0055 Adapter Cable As
(3) 275-5121 Communication Adapter Gp
(4) 332-7381 Adapter Cable As Note: Items (2), (3), and (4) are part of the 317-7484 Communication Adapter Gp.Use the following procedure in order to connect Cat ET and the Communication Adapter II.
Remove the electrical power from the ECM.
Connect cable (2) between the "COMPUTER" end of communication adapter (3) and the RS232 serial port of PC (1). Note: The 327-0375 Adapter Cable As is required to connect to the USB port on computers that are not equipped with an RS232 serial port.
Connect cable (4) between the "DATA LINK" end of communication adapter (3) and the service tool connector.
Restore the electrical power to the ECM. If Cat ET and the communication adapter do not communicate with the ECM, refer to the diagnostic procedure Troubleshooting, "Electronic Service Tool Does Not Communicate".
Parts tube JOHNSON:
5033150
5033150 TUBE, CDI LEAD
J10EL4SRC, J10R4SNF, J10R4SR, J10R4STC, J15R4SNF, J15R4SR, J15R4STC, J15RL4SR
5033151
5033151 TUBE, SWITCH LEAD
J10EL4SRC, J10R4SNF, J10R4SR, J10R4STC, J15R4SNF, J15R4SR, J15R4STC, J15RL4SR, J4R4SOR, J4R4SRC, J4R4STS, J5R4SRC, J5R4STS
5033220
5033220 TUBE, THROTTLE CABLE
J10EL4SRC, J10R4SNF, J10R4SR, J10R4STC, J15R4SNF, J15R4SR, J15R4STC, J15RL4SR
5033118
5033118 TUBE, WATER 15"
J10BL4SUM, J10EL4SDA, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SDM, J15TE4SUB
5033117
5033117 TUBE, WATER 20"
J10BL4SUM, J10EL4SDA, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SDM, J15TE4SUB
5033116
5033116 TUBE, WATER INLET
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5035605
5036274
5036274 *TUBE, SW LEAD
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10R4SDM, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SUB, J15RL4SDM, J15TE4SDM, J15TE4SUB