0511050 TUBING JOHNSON
100ESL72R, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115TXL77S, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 150TL78S, 175TL77S, 175TL78C, 200TL76S, 200TL77C, 200TL78R, 235TL78R, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 55E76E, 55E77D, 65ES72S,
TUBING
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
100ESL72R
115EL77S
115ESL73M
115ESL74B
115ESL75E
115TXL77S
125ESL72R
135ESL73M
135ESL74B
135ESL75E
140ML77S
150TL78S
175TL77S
175TL78C
200TL76S
200TL77C
200TL78R
235TL78R
50ES72C
50ES73R
50ES74M
50ES75B
55E76E
55E77D
65ES72S
65ES73R
70EL76D
70EL77S
70EL78C
70ES74M
70ES75B
75ELR76D
75ELR77S
75ELR78C
75ESLR75B
85EL76D
85EL77S
85ESL73M
85ESL74B
85ESL75E
85TXLR77S
JOHNSON
BRP JOHNSON entire parts catalog list:
- IGNITION SYSTEM » 0511050
115ESL73M 1973
115ESL74B, 115ETL74B 1974
115ESL75E, 115ETL75E 1975
115TXL77S 1977
125ESL72R 1972
135ESL73M 1973
135ESL74B, 135ETL74B 1974
135ESL75E, 135ETL75E 1975
140ML77S, 140TL77S, 140TXL77S 1977
150TL78S, 150TXL78S 1978
175TL77S, 175TXL77S 1977
175TL78C, 175TX78C 1978
200TL76S, 200TXL76S 1976
200TL77C, 200TXL77C 1977
200TL78R, 200TX78R 1978
235TL78R, 235TX78R 1978
50ES72C, 50ESL72C, 50R72C, 50RL72C 1972
50ES73R, 50ESL73R, 50R73R, 50RL73R 1973
50ES74M, 50ESL74M 1974
50ES75B, 50ESL75B 1975
55E76E, 55EL76E 1976
55E77D, 55EL77D 1977
65ES72S, 65ESL72S 1972
65ES73R, 65ESL73R 1973
70EL76D 1976
70EL77S 1977
70EL78C 1978
70ES74M, 70ESL74M, 70ESLR74M 1974
70ES75B, 70ES75E, 70ESL75B, 70ESL75E 1975
75ELR76D, 75ER76D 1976
75ELR77S, 75ER77S 1977
75ELR78C, 75ER78C 1978
75ESLR75B, 75ESR75B 1975
85EL76D, 85EL76G, 85ETLR76D, 85ETLR76G 1976
85EL77S, 85ETLR77S 1977
85ESL73M 1973
85ESL74B 1974
85ESL75E 1975
85TXLR77S 1977
Information:
Table 1
Diagnostic Trouble Codes    
CDL Code    Code Description    Comments    
3397-3     DPF #1 Soot Loading Sensor : Voltage Above Normal     The Electronic Control Module (ECM) detects voltage that is not in the acceptable range.
The code is logged.    
3397-4     DPF #1 Soot Loading Sensor : Voltage Below Normal     The ECM detects voltage that is not in the acceptable range.
The code is logged.    
3397-19     DPF #1 Soot Loading Sensor : Data Drifted Low     There is an electrical problem with soot sensing system.
The code is logged.    
3397-21     DPF #1 Soot Loading Sensor : Data Error     There is an electrical problem with soot sensing system.
The code is logged.    Test Step 1. Check for Active Diagnostic Codes
Establish communication between the Cat ET and the engine ECM.
Turn the keyswitch to the ON position.
Download the engine "Warranty Report" before performing any troubleshooting or clearing diagnostic trouble codes.
Troubleshoot any associated codes that are listed in Table 2 before continuing with this procedure.
Table 2
Associated Diagnostic Trouble Codes    
168     2,3 or 4    Results:
An associated code is active. - Repair: Troubleshoot the associated code.Verify that the problem is resolved.STOP
The 3397-3 diagnostic code is active. The voltage to the soot sensing system is above 32 VDC. - Repair: There is a problem with the harness and/or the connectors for the soot sensing module. Repair the harness and/or connectors or replace the harness and/or connectors. Refer to Illustration 1 for additional information.Verify that the problem is resolved.STOP
The 3397-4 diagnostic code is active. The voltage to the soot sensing system is below 9 VDC. - Repair: There is a problem with the harness and/or the connectors for the soot sensing module. Repair the harness and/or connectors or replace the harness and/or connectors. Refer to Illustration 1 for additional information.Verify that the problem is resolved.STOP
The 3397-21 diagnostic code is active. There is an electrical and/or mechanical problem with the soot sensing system. - Proceed to Test Step 2.Test Step 2. Check the Coaxial Cable and the Soot Sensing Module
Illustration 1 g02161091
Soot sensing module and connector
Inspect the coaxial cable. Verify that every connection for the coaxial cable in the soot sensing system is securely connected. Also, check each connection for dirt and water. The dirt and water must be cleaned from the connector each time a connection is made.
Illustration 2 g02177161
Connector torque point (1) Torque point
Torque every connector for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).
Reset all active codes and clear all logged codes. Verify that the problem is resolved.
If the problem is not resolved, disconnect the coaxial cable from the antennas.
Illustration 3 g02151941
366-7782 Attenuator
Connect the ends of the coaxial cable to the 366-7782 Attenuator . Refer to Illustration 3.
Perform the "DPF Soot Loading Sensor Functional Test" on Cat ET by selecting the following menus:
"Diagnostics"
"Diagnostic Tests"
"DPF Soot Loading Sensor Functional Test"Results:
The service test is successful. - Repair: Remove the antennas from the DPF in order to inspect for bent or broken probes.Replace any faulty antennas and reinstall the good antenna (if applicable).Torque the connector's for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).Verify that the problem is resolved.STOP
The service test is not successful. - Repair: Replace the soot sensing module.Torque the connectors for the coaxial cable to 1.2 N m (10.6 lb in) / -0.2 N m (1.8 lb in).Verify that the problem is resolved.STOP