0384719 JOHNSON VERNATHERM


0384719 VERNATHERM JOHNSON 100ESL71A, 100ESL72R, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 85EL76D, 85EL77S, 85ESL71A, 85ESL72R, 85ESL73M, 85ESL74B, 85ESL75E VERNATHERM
0384719 VERNATHERM JOHNSON
Rating:
103

Buy VERNATHERM 0384719 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 101
 

BRP JOHNSON entire parts catalog list:

100ESL71A, 100ESL71C 1971
100ESL72R 1972
115EL77S, 115ETL77 1977
115ESL73M 1973
115ESL74B, 115ETL74B 1974
115ESL75E, 115ETL75E 1975
125ESL71C 1971
125ESL72R 1972
135ESL73M 1973
135ESL74B, 135ETL74B 1974
135ESL75E, 135ETL75E 1975
85EL76D, 85EL76G, 85ETLR76D, 85ETLR76G 1976
85EL77S, 85ETLR77S 1977
85ESL71A, 85ESL71H 1971
85ESL72R 1972
85ESL73M 1973
85ESL74B 1974
85ESL75E 1975

Information:


Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Refer to Operation and Maintenance Manual, "General Hazard Information and High Pressure Fuel Lines" before adjustments and repairs are performed.
Refer to Systems Operation, Testing and Adjusting, "Cleanliness of Fuel System Components" for detailed information on the standards of cleanliness that must be observed during ALL work on the fuel system.
Ensure that all adjustments and repairs are performed by authorized personnel that have had the correct training.
Illustration 1 g02293673
Typical example
Table 1
Specifications for 345-4146 Fuel Injection Lines Gp and 345-4147 Fuel Injection Lines Gp
Callout Part Number Part Name Specification Description
1 345-4146 Fuel Injection Lines Gp Torque to................... 55 N m (41 lb ft)
1 345-4147 Fuel Injection Lines Gp Torque to................... 55 N m (41 lb ft)
2 338-8797 Line As - Fuel Torque to................... 55 N m (41 lb ft) Removal Procedure
Table 2
Required Tools
Tool Part Number Part Description Qty
A 370-8376 Cap Kit 1
Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Ensure that all adjustments and repairs that are carried out to the fuel system are performed by authorized personnel that have the correct training.Before beginning ANY work on the fuel system, refer to Operation and Maintenance Manual, "General Hazard Information and High Pressure Fuel Lines" for safety information.Refer to System Operation, Testing and Adjusting, "Cleanliness of Fuel System Components" for detailed information on the standards of cleanliness that must be observed during ALL work on the fuel system.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Note: Put identification marks on all hoses on all hose assemblies and on wires and all tube assemblies for installation purposes. Plug all hose assemblies and tube assemblies. Plugging all hose assemblies and tube assemblies will help to prevent fluid loss and helps to keep contaminants from entering the system.
Turn the fuel supply to the OFF position.
Turn the battery disconnect switch to the OFF position.
Remove the inlet air control (NRS Induction Mixer) and mounting bracket. Refer to Disassembly and Assembly, "Inlet Air Control (NRS Induction Mixer)" for the correct procedure.
Remove the crankcase breather cannister and tube assemblies. Refer to Disassembly and Assembly, "Crankcase Breather" for the correct procedure.
Illustration 2 g02177626
Cut cable straps (6) from the wiring harness assemblies.
Slide the locking tab for wiring harness connection (2) into the unlocked position. Remove wiring harness connection (2) from the pressure sensor.
Slide the locking tab for wiring harness connection (3) into the unlocked position. Remove wiring harness connection (3) from the pressure sensor.
Slide wiring harness connection (7) from the mounting bracket and position harness away from the inlet elbow.
Remove bolt (4) and bolt (8) from clips for tube assemblies.
Remove bolts (5) and remove manifold (1) from the inlet elbow.
Illustration 3 g02177627
Remove bolts (9) and remove inlet elbow (10) from the cylinder head.
Remove gasket (11).