15842 BEARING, Thrust Mariner
7002201DK, 7115473JD, 71354120D, 7135412AD, 7135412ED, 7135412HD, 7135412JD, 7135417PD, 7135473GD, 7135473HD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413ED, 7150413HD, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7150423JD, 7175412PD, 7175413A
BEARING
Price: query
Rating:
Compatible models:
7002201DK
7115473JD
71354120D
7135412AD
7135412ED
7135412HD
7135412JD
7135417PD
7135473GD
7135473HD
7135473KD
7135D73RD
7135D73UY
7135D73ZY
7150413ED
7150413HD
7150413LD
7150413RD
7150413UY
7150413ZY
7150423JD
7175412PD
7175413AD
7175423HD
7200412PD
7200413JD
7200413UY
7200413ZY
7200423UY
7200473FD
7200473GD
7200473HD
7200473JD
7200473KD
7200D73MD
7200D73RD
7200D73ZY
7225412CD
7225412HD
7225413DD
7225413HD
7225413LD
7225413RD
7225413ZY
7225E73MD
7250422PD
Mariner
Mariner entire parts catalog list:
7115473JD 2000
71354120D 1990,1991
7135412AD 1992,1993,1994,1995
7135412ED 1996,1997,1998
- GEAR HOUSING(PROPSHAFT-COUNTER-S-N-0G438000 & UP) » 15842
- GEAR HOUSING(PROPSHAFT-COUNTER-S-N-0G437999 & BELOW) » 15842
7135412JD 2000,2001,2002,2003,2004,2005
7135417PD 1989
7135473GD 1998
7135473HD 1999
7135473KD 2001,2002,2003
7135D73RD 2004,2005
7135D73UY 2006
7135D73ZY 2006
7150413ED 1996,1997,1998
- GEAR HSG(PROP SHAFT)(CNTR ROTATION) (S-N-0G438000, UP) » 15842
- GEAR HSG(PROP SHAFT)(CNTR ROTATION) (S-N-0G437999, BELOW) » 15842
7150413LD 2002,2003
7150413RD 2004,2005
7150413UY 2006
7150413ZY 2006
7150423JD 2000,2001
7175412PD 1989
7175413AD 1992,1993,1994,1995
7175423HD 1999
7200412PD 1989,1990
7200413JD 2000
- GEAR HSG(PROPSHAFT)(C-R)(S-N-0G960500 & UP) » 15842
- GEAR HSG(PROPSHAFT) (C-R)(S-N-0G960499 & BELOW) » 15842
- GEAR HOUSING(PROP SHAFT)(COUNTER ROTATION) » 15842
7200413ZY 2006
7200423UY 2006
7200473FD 1997
- GEAR HSG(PROP SHAFT)COUNTER ROTATION(G437999 & BELOW) » 15842
- GEAR HSG(PROP SHAFT)COUNTER ROTATION(0G438000 & UP) » 15842
7200473HD 1999
7200473JD 2000
7200473KD 2001,2002
7200D73MD 2003
7200D73RD 2004,2005,2006
7200D73ZY 2006
7225412CD 1994,1995,1996,1997,1998
- G.-HSG, PROP-C-R-S-N-0G437999 & BELOW-1623-822442C2 CASTING » 15842
- G-HSG, PROP-COUNTER-G438000 AND UP-1623-822442C3 » 15842
- GEAR HSG(PROPSHAFT-C-R-S-N-0G960500 & UP) » 15842
- GEAR HSG(PROPSHAFT-C-R-S-N-0G960499 & BELOW) » 15842
- G-HSG, PROP-COUNTER-G438000 AND UP-1623-822442C3 » 15842
- G-HSG, PROP-COUNTER-0G437999 AND BELOW-1623-822442C2 » 15842
- GEAR HSG(PROPSHAFT)(C-R)(S-N-0G960500 & UP) » 15842
- GEAR HSG(PROPSHAFT) (C-R)(S-N-0G960499 & BELOW) » 15842
7225413RD 2004,2005,2006
7225413ZY 2006
7225E73MD 2003,2004
7250422PD 1989,1990,1991,1992,1993,1994
Information:
High/Low Logic Circuit
Illustration 1 g00487533
System Schematic For Spare OutputWhen used as a high/low logic circuit.The spare output on the GSC is strictly used for the customer. The spare output is programmed to activate under a variety of conditions. The default is set for the output to activate when the engine is in the cooldown (SP11 = 7). The GSC treats this diagnostic code as a alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The responsibility of documenting any connections to this spare output falls on the customer and/or the dealer. Also, The responsibility of troubleshooting any connections to this spare output falls on the customer and/or the dealer. The voltage on the spare output is approximately 3.0 DCV when the spare output is not active. The voltage is approximately 3.0 DCV when there are no connections to the spare output. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground ("B-") of the signal for the spare output is present.Troubleshooting of a spare output fault is direct. The FMI defines the diagnostic code. FMI 4 is a short to ground. In order to find the exact cause of the diagnostic code, use the following information: the FMI, the system schematic for the spare output and the documentation that is provided by the dealer and/or the customerSerial Data Link
Illustration 2 g00487536
System Schematic For Spare OutputWhen used as a serial data link.The GSC communicates with the relay driver module (RDM) by a serial data link. The serial data link is enabled when the setpoint SP11 is 9. For more information, see Systems Operation, "Spare Input/Output Programming OP6".When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays "R2" through "R9" will maintain the current states or the relays will default to off. This is controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs ("R2" through "R9") will maintain the current states. If the jumper is present, "R2" through "R9" will default to OFF. Note: The maximum distance between a module and the GSC is 305 m (1000 ft). If this specification is not met, it is possible for the data link to malfunction. Also, a diagnostic code of CID 334 could occur. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC.Note: Faults are created when the harness connector (40 contact) is disconnected from the GSC during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic code is corrected. In a properly operating system, when the harness connector is removed from the GSC, the following diagnostic codes are recorded:
CID 100 FMI 2 pressure sensor (engine oil)
CID 110 FMI 2 temperature sensor (engine coolant)
CID 111 FMI 3 fluid level sensor (engine coolant)
CID 190 FMI 3 speed sensor (engine)
CID 336 FMI 2 switch (engine control)
CID 590 FMI 9 engine ECMProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground of the signal for the data is present.The GSC is not able to detect an open circuit condition of the data link for the relay driver module. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the voltage of the signal for the data.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead).Expected Result: The voltage should change constantly. The voltage should change within the range of 0 to 10 DCV.Results:
OK - The voltage measurement is correct. Proceed to 3.
NOT OK - The voltage measurement is NOT correct. Proceed to 2.
Check the voltage of RDM and the GSC.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Voltage should be 11.6 0.5 DCV.
Measure the voltage from the contact 36 of the GSC to the ground ("B-") terminal of the relay module. The voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Expected Result: For 2.c, the voltage should be 11.6 0.5 DCV. For 2.d, the voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Results:
OK - Both voltage measurements are correct. Proceed to 3.
NOT OK - Voltage measured at the RDM is NOT correct. Replace the RDM. STOP.
NOT OK - Voltage measured at the GSC is NOT correct. Replace the GSC. STOP.
Check for the short in the harness.
Disconnect the harness connector from the GSC.
At the RDM, remove wire 1-PK from terminal 4.
Measure the resistance from the wire at RDM terminal 4 to the positive battery ("B+") terminal of the relay module on the rear of the GSC.
Measure the resistance from the wire at RDM terminal 4 to ground ("B-") terminal of the relay module on the rear of the GSC.Expected Result: Both measurements should be greater than 20000 ohms. Results:
OK - Both resistance measurements are correct. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". If the diagnostic code still exists after the inspection, replace the RDM. STOP.
NOT OK - Either one or both of the resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is shorted. Troubleshoot and repair the faulty harness wiring between the RDM and the GSC. See the preceding System Schematic. STOP.
Illustration 1 g00487533
System Schematic For Spare OutputWhen used as a high/low logic circuit.The spare output on the GSC is strictly used for the customer. The spare output is programmed to activate under a variety of conditions. The default is set for the output to activate when the engine is in the cooldown (SP11 = 7). The GSC treats this diagnostic code as a alarm fault. For more information, see Systems Operation, "Spare Input/Output Programming OP6". The responsibility of documenting any connections to this spare output falls on the customer and/or the dealer. Also, The responsibility of troubleshooting any connections to this spare output falls on the customer and/or the dealer. The voltage on the spare output is approximately 3.0 DCV when the spare output is not active. The voltage is approximately 3.0 DCV when there are no connections to the spare output. When the spare output is active, the voltage on the spare output is approximately 0 volts. The spare output is capable of drawing (sinking) approximately 100 mA.ProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground ("B-") of the signal for the spare output is present.Troubleshooting of a spare output fault is direct. The FMI defines the diagnostic code. FMI 4 is a short to ground. In order to find the exact cause of the diagnostic code, use the following information: the FMI, the system schematic for the spare output and the documentation that is provided by the dealer and/or the customerSerial Data Link
Illustration 2 g00487536
System Schematic For Spare OutputWhen used as a serial data link.The GSC communicates with the relay driver module (RDM) by a serial data link. The serial data link is enabled when the setpoint SP11 is 9. For more information, see Systems Operation, "Spare Input/Output Programming OP6".When the data link malfunctions, R1 output (terminal 2 of the RDM) will be activated on and off at a rate of 0.5 Hz. Relays "R2" through "R9" will maintain the current states or the relays will default to off. This is controlled by a jumper between terminals 6 and 7 of the RDM. If a jumper is NOT present when the serial data link has a fault, the relay outputs ("R2" through "R9") will maintain the current states. If the jumper is present, "R2" through "R9" will default to OFF. Note: The maximum distance between a module and the GSC is 305 m (1000 ft). If this specification is not met, it is possible for the data link to malfunction. Also, a diagnostic code of CID 334 could occur. If the distance is not in compliance with the specification, shorten the distance between the RDM and the GSC.Note: Faults are created when the harness connector (40 contact) is disconnected from the GSC during these troubleshooting procedures. Clear these created diagnostic codes after the particular diagnostic code is corrected. In a properly operating system, when the harness connector is removed from the GSC, the following diagnostic codes are recorded:
CID 100 FMI 2 pressure sensor (engine oil)
CID 110 FMI 2 temperature sensor (engine coolant)
CID 111 FMI 3 fluid level sensor (engine coolant)
CID 190 FMI 3 speed sensor (engine)
CID 336 FMI 2 switch (engine control)
CID 590 FMI 9 engine ECMProcedureThe following condition could be a possible cause of a CID 334 FMI 4.
A short to the ground of the signal for the data is present.The GSC is not able to detect an open circuit condition of the data link for the relay driver module. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the voltage of the signal for the data.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead).Expected Result: The voltage should change constantly. The voltage should change within the range of 0 to 10 DCV.Results:
OK - The voltage measurement is correct. Proceed to 3.
NOT OK - The voltage measurement is NOT correct. Proceed to 2.
Check the voltage of RDM and the GSC.
At the RDM, disconnect all wires from terminal 4.
Disconnect the harness connector from the GSC.
At the RDM, measure the DC voltage from terminal 4 (positive meter lead) to terminal 7 (negative meter lead). Voltage should be 11.6 0.5 DCV.
Measure the voltage from the contact 36 of the GSC to the ground ("B-") terminal of the relay module. The voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Expected Result: For 2.c, the voltage should be 11.6 0.5 DCV. For 2.d, the voltage should change constantly. The voltage should change within the range of 0 to 5.5 DCV. Results:
OK - Both voltage measurements are correct. Proceed to 3.
NOT OK - Voltage measured at the RDM is NOT correct. Replace the RDM. STOP.
NOT OK - Voltage measured at the GSC is NOT correct. Replace the GSC. STOP.
Check for the short in the harness.
Disconnect the harness connector from the GSC.
At the RDM, remove wire 1-PK from terminal 4.
Measure the resistance from the wire at RDM terminal 4 to the positive battery ("B+") terminal of the relay module on the rear of the GSC.
Measure the resistance from the wire at RDM terminal 4 to ground ("B-") terminal of the relay module on the rear of the GSC.Expected Result: Both measurements should be greater than 20000 ohms. Results:
OK - Both resistance measurements are correct. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". If the diagnostic code still exists after the inspection, replace the RDM. STOP.
NOT OK - Either one or both of the resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is shorted. Troubleshoot and repair the faulty harness wiring between the RDM and the GSC. See the preceding System Schematic. STOP.
Parts bearing Mariner:
67923
67923 BEARING, Ball (LOWER)
7002201DK, 71354120D, 7135412AD, 7135412ED, 7135412HD, 7135417PD, 7135473GD, 7135473HD, 7135826, 7150413ED, 7150413HD, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175413AD, 7175413PD, 7175413YD, 7175423HD, 7175629, 7200412PD, 7200473FD, 7200473GD, 720
17514A 1
17514A 1 BEARING KIT
7031203GD, 7031207LF, 7031312TB, 7041203GB, 70432037D, 7043213HD, 7043213TD, 7043302TD, 7043412TB, 7043412TD, 7050312TB, 7050312UB, 7050412TB, 7050412TD, 7050412UB, 7050412YD, 7055207GD, 7055207HB, 7055207TF, 7060412ET, 7115473JD, 71354120D, 7135473H
93495
93495 BEARING, Roller, CRANKSHAFT
7135417PD, 7135826, 7150453ND, 7150453PD, 7150629, 7175412PD, 7175629, 7200412PD, 7220727
814103
815362A 1
817631
816974
803033T 1
803033T 1 BEARING AND SEAL KIT (W/O FORWARD BRG.)
7115473JD, 7135412JD, 7135473KD, 7135D73RD, 7135D73UY, 7135D73ZY, 7150413LD, 7150413RD, 7150413UY, 7150413ZY, 7150423JD, 7200413JD, 7200413UY, 7200413ZY, 7200423UY